Cargando…
Proficiencies of military medical officers in intubating difficult airways
BACKGROUND: This study sheds light on the proficiency of military medical officers who had received between 2 and 3 years of post-graduate training, in the handling of the difficult airway in a trauma manikin simulator using direct and video laryngoscopes. METHOD: One hundred thirty-three doctors fr...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7542123/ https://www.ncbi.nlm.nih.gov/pubmed/33028220 http://dx.doi.org/10.1186/s12873-020-00375-2 |
Sumario: | BACKGROUND: This study sheds light on the proficiency of military medical officers who had received between 2 and 3 years of post-graduate training, in the handling of the difficult airway in a trauma manikin simulator using direct and video laryngoscopes. METHOD: One hundred thirty-three doctors from the Singapore Armed Forces Medical Officer Cadet Course were assessed using high-fidelity simulator models with standardised difficult airways (simulator with tongue-swelling and cervical collar). They used the Macintosh direct laryngoscope (DL), King Vision channelled-blade laryngoscope (KVC), King Vision non-channelled blade laryngoscope (KVNC), and the McGrath (MG) laryngoscope on the same model in a randomised sequence. The intubation success rates and time to intubation were recorded and analysed for the study. RESULTS: The medical officers had a 71.4% intubation success rate with the DL on the difficult airway trauma simulator model and the mean time to intubation of 40.1 s. With the KVC, the success rate is 86.5% with mean intubation time of 40.4 s. The KVNC produced 24.8% success rate, with mean time to intubation of 53.2 s. The MG laryngoscope produced 85.0% success rate, with a mean time of intubation of 37.4 s. CONCLUSION: Military medical officers with 2–3 years of post-graduate training had a success rate of 71.4% success rate intubating a simulated difficult airway in a trauma setting using a DL. Success rates were improved with the use of KVC and the MG laryngoscope, but was worse with the KVNC. |
---|