Cargando…
The application of Patient specific Instrument (PSI )in total knee arthroplasty with valgus knee
INTRODUCTION: To invest the auxiliary role of Patient specific Instrument(PSI) used as osteotomy guide plate in total knee arthroplasty(TKA) with valgus knee. HYPOTHESES: PSI osteotomy guide plate is applicable for total knee arthroplasty with valgus knee. METHODS: A retrospective analysis was perfo...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7543159/ http://dx.doi.org/10.1177/2325967120S00545 |
_version_ | 1783591680932315136 |
---|---|
author | Yuehui, Wang Shiping, Zou Liangliang, Cao Wenzhong, Chen |
author_facet | Yuehui, Wang Shiping, Zou Liangliang, Cao Wenzhong, Chen |
author_sort | Yuehui, Wang |
collection | PubMed |
description | INTRODUCTION: To invest the auxiliary role of Patient specific Instrument(PSI) used as osteotomy guide plate in total knee arthroplasty(TKA) with valgus knee. HYPOTHESES: PSI osteotomy guide plate is applicable for total knee arthroplasty with valgus knee. METHODS: A retrospective analysis was performed on 21 patients with valgus knee, including 5 males and 16 females, who underwent TKA in joint surgery department I of ZhengZhou Orthopaedic Hospital from March 2016 to February 2018. All the operations were performed with the assistance of PSI, and the radiographic and clinical evaluations including femoral tibial joint ectropion angle(FTA) before and after operation, range of motion(ROM) and the Hospital for Special Surgery (HSS) knee score were reviewed, and surgical complications were recorded. RESULTS: All the 21 patients werefollowed up for 10 ˜ 26 months (mean 16 months).All the incisions healed by first intention. The FTA was reduced significantly to 6.3 °±1.2° after operation from 17.6 ° + 5.7 °(P < 0.05), the ROM was improved significantly from preoperative 71.3° ±5.8° to postoperative 102.4°±7.5° (P < 0.05), the HSS score at the last follow-up was improved from 38.2±5.7 to 87.5-3.5(P < 0.05). During the follow-up, no complications such as infection, loosening, sinking and valgus were observed. CONCLUSION: Providing accurate osteotomy, effective correction of the force line, simple operation and satisfactory clinical effect, the PSI osteotomy guide plate is applicable for total knee arthroplasty with valgus knee. |
format | Online Article Text |
id | pubmed-7543159 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | SAGE Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-75431592020-10-20 The application of Patient specific Instrument (PSI )in total knee arthroplasty with valgus knee Yuehui, Wang Shiping, Zou Liangliang, Cao Wenzhong, Chen Orthop J Sports Med Article INTRODUCTION: To invest the auxiliary role of Patient specific Instrument(PSI) used as osteotomy guide plate in total knee arthroplasty(TKA) with valgus knee. HYPOTHESES: PSI osteotomy guide plate is applicable for total knee arthroplasty with valgus knee. METHODS: A retrospective analysis was performed on 21 patients with valgus knee, including 5 males and 16 females, who underwent TKA in joint surgery department I of ZhengZhou Orthopaedic Hospital from March 2016 to February 2018. All the operations were performed with the assistance of PSI, and the radiographic and clinical evaluations including femoral tibial joint ectropion angle(FTA) before and after operation, range of motion(ROM) and the Hospital for Special Surgery (HSS) knee score were reviewed, and surgical complications were recorded. RESULTS: All the 21 patients werefollowed up for 10 ˜ 26 months (mean 16 months).All the incisions healed by first intention. The FTA was reduced significantly to 6.3 °±1.2° after operation from 17.6 ° + 5.7 °(P < 0.05), the ROM was improved significantly from preoperative 71.3° ±5.8° to postoperative 102.4°±7.5° (P < 0.05), the HSS score at the last follow-up was improved from 38.2±5.7 to 87.5-3.5(P < 0.05). During the follow-up, no complications such as infection, loosening, sinking and valgus were observed. CONCLUSION: Providing accurate osteotomy, effective correction of the force line, simple operation and satisfactory clinical effect, the PSI osteotomy guide plate is applicable for total knee arthroplasty with valgus knee. SAGE Publications 2020-09-30 /pmc/articles/PMC7543159/ http://dx.doi.org/10.1177/2325967120S00545 Text en © The Author(s) 2020 https://creativecommons.org/licenses/by-nc-nd/4.0/ This open-access article is published and distributed under the Creative Commons Attribution - NonCommercial - No Derivatives License (https://creativecommons.org/licenses/by-nc-nd/4.0/), which permits the noncommercial use, distribution, and reproduction of the article in any medium, provided the original author and source are credited. You may not alter, transform, or build upon this article without the permission of the Author(s). For article reuse guidelines, please visit SAGE’s website at http://www.sagepub.com/journals-permissions. |
spellingShingle | Article Yuehui, Wang Shiping, Zou Liangliang, Cao Wenzhong, Chen The application of Patient specific Instrument (PSI )in total knee arthroplasty with valgus knee |
title | The application of Patient specific Instrument (PSI )in total knee arthroplasty with valgus knee |
title_full | The application of Patient specific Instrument (PSI )in total knee arthroplasty with valgus knee |
title_fullStr | The application of Patient specific Instrument (PSI )in total knee arthroplasty with valgus knee |
title_full_unstemmed | The application of Patient specific Instrument (PSI )in total knee arthroplasty with valgus knee |
title_short | The application of Patient specific Instrument (PSI )in total knee arthroplasty with valgus knee |
title_sort | application of patient specific instrument (psi )in total knee arthroplasty with valgus knee |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7543159/ http://dx.doi.org/10.1177/2325967120S00545 |
work_keys_str_mv | AT yuehuiwang theapplicationofpatientspecificinstrumentpsiintotalkneearthroplastywithvalgusknee AT shipingzou theapplicationofpatientspecificinstrumentpsiintotalkneearthroplastywithvalgusknee AT liangliangcao theapplicationofpatientspecificinstrumentpsiintotalkneearthroplastywithvalgusknee AT wenzhongchen theapplicationofpatientspecificinstrumentpsiintotalkneearthroplastywithvalgusknee AT yuehuiwang applicationofpatientspecificinstrumentpsiintotalkneearthroplastywithvalgusknee AT shipingzou applicationofpatientspecificinstrumentpsiintotalkneearthroplastywithvalgusknee AT liangliangcao applicationofpatientspecificinstrumentpsiintotalkneearthroplastywithvalgusknee AT wenzhongchen applicationofpatientspecificinstrumentpsiintotalkneearthroplastywithvalgusknee |