Cargando…

Clinical and functional outcomes of ACL reconstruction with tibial attachment preserving quadrupled hamstring graft

INTRODUCTION: Recent literature supports the preservation of tibial attachment of hamstring grafts to enhance ‘‘ligamentization’’ process and prevent the potential problems of free graft such as pull-out or rupture in the early post-operative period. Another factor that has gained attention in recen...

Descripción completa

Detalles Bibliográficos
Autores principales: Dalal, Shaival, Aminake, Ghislain, Guro, Randy, Chandratreya, Amit, Kotwal, Rahul
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7543182/
http://dx.doi.org/10.1177/2325967120S00550
_version_ 1783591684009885696
author Dalal, Shaival
Aminake, Ghislain
Guro, Randy
Chandratreya, Amit
Kotwal, Rahul
author_facet Dalal, Shaival
Aminake, Ghislain
Guro, Randy
Chandratreya, Amit
Kotwal, Rahul
author_sort Dalal, Shaival
collection PubMed
description INTRODUCTION: Recent literature supports the preservation of tibial attachment of hamstring grafts to enhance ‘‘ligamentization’’ process and prevent the potential problems of free graft such as pull-out or rupture in the early post-operative period. Another factor that has gained attention in recent days is graft diameter, which can be variable and is thought to be a factor contributing to graft failure in biomechanical and clinical studies. Numerous studies have shown conflicting evidence of graft diameter directly influencing the graft failure. HYPOTHESES: The aim of this study is to present our results of ACL reconstruction with preservation of the tibial attachment of the hamstring grafts along with loop-stitched quadrupled hamstring grafts fixed with Endobutton on the femoral side and an interference screw and staple on the tibial side. METHODS: Prospective single-surgeon case-series evaluating patients undergoing surgery by this technique. Patients were followed up clinically and using PROMS from NLR with EQ-5D, KOOS, IKDC and Tegner scores. Paired two-tailed student t-tests were used to assess significance. RESULTS: 45 patients had associated meniscal tear with 73.3 % undergoing repair. 3 cases (4.6 %) returned to theatre including, MUA for arthrofibrosis (n=1) and meniscal repair for recurrent medial meniscus tear (n=2). Incidence of graft re-rupture was seen in 1 patient. At a mean follow-up of 2.3 years, 80% (n=51) had complete peri-operative PROMS scores. Mean peri-operative EQ-5D VAS, EQ-5D Index, KOOS, IKDC and Tegner activity scores showed significant improvement (p<0.001). Multiple regression analysis does not find any correlation between PROMS and graft diameter. CONCLUSION: ACL reconstruction using tibial attachment preserving hamstring graft is a simple and , reproducible, and cost-effective technique that gives consistent clinical and functional outcomes, irrespective of the graft diameter . The natural tibial side insertion provides secure fixation and adds biology to the anatomic reconstruction, possibly reducing the re-rupture and failure rate.
format Online
Article
Text
id pubmed-7543182
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-75431822020-10-20 Clinical and functional outcomes of ACL reconstruction with tibial attachment preserving quadrupled hamstring graft Dalal, Shaival Aminake, Ghislain Guro, Randy Chandratreya, Amit Kotwal, Rahul Orthop J Sports Med Article INTRODUCTION: Recent literature supports the preservation of tibial attachment of hamstring grafts to enhance ‘‘ligamentization’’ process and prevent the potential problems of free graft such as pull-out or rupture in the early post-operative period. Another factor that has gained attention in recent days is graft diameter, which can be variable and is thought to be a factor contributing to graft failure in biomechanical and clinical studies. Numerous studies have shown conflicting evidence of graft diameter directly influencing the graft failure. HYPOTHESES: The aim of this study is to present our results of ACL reconstruction with preservation of the tibial attachment of the hamstring grafts along with loop-stitched quadrupled hamstring grafts fixed with Endobutton on the femoral side and an interference screw and staple on the tibial side. METHODS: Prospective single-surgeon case-series evaluating patients undergoing surgery by this technique. Patients were followed up clinically and using PROMS from NLR with EQ-5D, KOOS, IKDC and Tegner scores. Paired two-tailed student t-tests were used to assess significance. RESULTS: 45 patients had associated meniscal tear with 73.3 % undergoing repair. 3 cases (4.6 %) returned to theatre including, MUA for arthrofibrosis (n=1) and meniscal repair for recurrent medial meniscus tear (n=2). Incidence of graft re-rupture was seen in 1 patient. At a mean follow-up of 2.3 years, 80% (n=51) had complete peri-operative PROMS scores. Mean peri-operative EQ-5D VAS, EQ-5D Index, KOOS, IKDC and Tegner activity scores showed significant improvement (p<0.001). Multiple regression analysis does not find any correlation between PROMS and graft diameter. CONCLUSION: ACL reconstruction using tibial attachment preserving hamstring graft is a simple and , reproducible, and cost-effective technique that gives consistent clinical and functional outcomes, irrespective of the graft diameter . The natural tibial side insertion provides secure fixation and adds biology to the anatomic reconstruction, possibly reducing the re-rupture and failure rate. SAGE Publications 2020-09-30 /pmc/articles/PMC7543182/ http://dx.doi.org/10.1177/2325967120S00550 Text en © The Author(s) 2020 https://creativecommons.org/licenses/by-nc-nd/4.0/ This open-access article is published and distributed under the Creative Commons Attribution - NonCommercial - No Derivatives License (https://creativecommons.org/licenses/by-nc-nd/4.0/), which permits the noncommercial use, distribution, and reproduction of the article in any medium, provided the original author and source are credited. You may not alter, transform, or build upon this article without the permission of the Author(s). For article reuse guidelines, please visit SAGE’s website at http://www.sagepub.com/journals-permissions.
spellingShingle Article
Dalal, Shaival
Aminake, Ghislain
Guro, Randy
Chandratreya, Amit
Kotwal, Rahul
Clinical and functional outcomes of ACL reconstruction with tibial attachment preserving quadrupled hamstring graft
title Clinical and functional outcomes of ACL reconstruction with tibial attachment preserving quadrupled hamstring graft
title_full Clinical and functional outcomes of ACL reconstruction with tibial attachment preserving quadrupled hamstring graft
title_fullStr Clinical and functional outcomes of ACL reconstruction with tibial attachment preserving quadrupled hamstring graft
title_full_unstemmed Clinical and functional outcomes of ACL reconstruction with tibial attachment preserving quadrupled hamstring graft
title_short Clinical and functional outcomes of ACL reconstruction with tibial attachment preserving quadrupled hamstring graft
title_sort clinical and functional outcomes of acl reconstruction with tibial attachment preserving quadrupled hamstring graft
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7543182/
http://dx.doi.org/10.1177/2325967120S00550
work_keys_str_mv AT dalalshaival clinicalandfunctionaloutcomesofaclreconstructionwithtibialattachmentpreservingquadrupledhamstringgraft
AT aminakeghislain clinicalandfunctionaloutcomesofaclreconstructionwithtibialattachmentpreservingquadrupledhamstringgraft
AT gurorandy clinicalandfunctionaloutcomesofaclreconstructionwithtibialattachmentpreservingquadrupledhamstringgraft
AT chandratreyaamit clinicalandfunctionaloutcomesofaclreconstructionwithtibialattachmentpreservingquadrupledhamstringgraft
AT kotwalrahul clinicalandfunctionaloutcomesofaclreconstructionwithtibialattachmentpreservingquadrupledhamstringgraft