Cargando…
COVID-19 risk stratification algorithms based on sTREM-1 and IL-6 in emergency department
BACKGROUND: The coronavirus disease 2019 (COVID-19) pandemic has led to surges of patients presenting to emergency departments (EDs) and potentially overwhelming health systems. OBJECTIVE: We sought to assess the predictive accuracy of host biomarkers at clinical presentation to the ED for adverse o...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
American Academy of Allergy, Asthma & Immunology
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7546666/ https://www.ncbi.nlm.nih.gov/pubmed/33045281 http://dx.doi.org/10.1016/j.jaci.2020.10.001 |
Sumario: | BACKGROUND: The coronavirus disease 2019 (COVID-19) pandemic has led to surges of patients presenting to emergency departments (EDs) and potentially overwhelming health systems. OBJECTIVE: We sought to assess the predictive accuracy of host biomarkers at clinical presentation to the ED for adverse outcome. METHODS: Prospective observational study of PCR-confirmed COVID-19 patients in the ED of a Swiss hospital. Concentrations of inflammatory and endothelial dysfunction biomarkers were determined at clinical presentation. We evaluated the accuracy of clinical signs and these biomarkers in predicting 30-day intubation/mortality, and oxygen requirement by calculating the area under the receiver-operating characteristic curve and by classification and regression tree analysis. RESULTS: Of 76 included patients with COVID-19, 24 were outpatients or hospitalized without oxygen requirement, 35 hospitalized with oxygen requirement, and 17 intubated/died. We found that soluble triggering receptor expressed on myeloid cells had the best prognostic accuracy for 30-day intubation/mortality (area under the receiver-operating characteristic curve, 0.86; 95% CI, 0.77-0.95) and IL-6 measured at presentation to the ED had the best accuracy for 30-day oxygen requirement (area under the receiver-operating characteristic curve, 0.84; 95% CI, 0.74-0.94). An algorithm based on respiratory rate and sTREM-1 predicted 30-day intubation/mortality with 94% sensitivity and 0.1 negative likelihood ratio. An IL-6–based algorithm had 98% sensitivity and 0.04 negative likelihood ratio for 30-day oxygen requirement. CONCLUSIONS: sTREM-1 and IL-6 concentrations in COVID-19 in the ED have good predictive accuracy for intubation/mortality and oxygen requirement. sTREM-1– and IL-6–based algorithms are highly sensitive to identify patients with adverse outcome and could serve as early triage tools. |
---|