Experimental investigation into the effect of compliance of a mock aorta on cardiac performance

Demand for heart transplants far exceeds supply of donated organs. This is attributed to the high percentage of donor hearts that are discarded and to the narrow six-hour time window currently available for transplantation. Ex-vivo heart perfusion (EVHP) provides the opportunity for resuscitation of...

Descripción completa

Detalles Bibliográficos
Autores principales: Cameron, Katie, El Hassan, Mouhammad, Sabbagh, Reza, Freed, Darren H., Nobes, David S.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7549783/
https://www.ncbi.nlm.nih.gov/pubmed/33044976
http://dx.doi.org/10.1371/journal.pone.0239604
_version_ 1783592846209581056
author Cameron, Katie
El Hassan, Mouhammad
Sabbagh, Reza
Freed, Darren H.
Nobes, David S.
author_facet Cameron, Katie
El Hassan, Mouhammad
Sabbagh, Reza
Freed, Darren H.
Nobes, David S.
author_sort Cameron, Katie
collection PubMed
description Demand for heart transplants far exceeds supply of donated organs. This is attributed to the high percentage of donor hearts that are discarded and to the narrow six-hour time window currently available for transplantation. Ex-vivo heart perfusion (EVHP) provides the opportunity for resuscitation of damaged organs and extended transplantation time window by enabling functional assessment of the hearts in a near-physiologic state. Present work investigates the fluid mechanics of the ex-vivo flow loop and corresponding impact on cardiac performance. A mechanical flow loop is developed that is analogous to the region of the EVHP system that mimics in-vivo systemic circulation, including the body’s largest and most compliant artery, the aorta. This investigation is focused on determining the effect of mock aortic tubing compliance on pump performance. A custom-made silicone mock aorta was developed to simulate a range of in-vivo conditions and a physiological flow was generated using a commercial ventricular assist device (VAD). Monitored parameters, including pressure, tube distension and downstream velocity, acquired using time-resolved particle imaging velocimetry (PIV), were applied to an unsteady Bernoulli analysis of the flow in a novel way to evaluate pump performance as a proxy for cardiac workload. When compared to the rigid case, the compliant mock aorta case demonstrated healthier physiologic pressure waveforms, steadier downstream flow and reduced energetic demands on the pump. These results provide experimental verification of Windkessel theory and support the need for a compliant mock aorta in the EVHP system.
format Online
Article
Text
id pubmed-7549783
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-75497832020-10-20 Experimental investigation into the effect of compliance of a mock aorta on cardiac performance Cameron, Katie El Hassan, Mouhammad Sabbagh, Reza Freed, Darren H. Nobes, David S. PLoS One Research Article Demand for heart transplants far exceeds supply of donated organs. This is attributed to the high percentage of donor hearts that are discarded and to the narrow six-hour time window currently available for transplantation. Ex-vivo heart perfusion (EVHP) provides the opportunity for resuscitation of damaged organs and extended transplantation time window by enabling functional assessment of the hearts in a near-physiologic state. Present work investigates the fluid mechanics of the ex-vivo flow loop and corresponding impact on cardiac performance. A mechanical flow loop is developed that is analogous to the region of the EVHP system that mimics in-vivo systemic circulation, including the body’s largest and most compliant artery, the aorta. This investigation is focused on determining the effect of mock aortic tubing compliance on pump performance. A custom-made silicone mock aorta was developed to simulate a range of in-vivo conditions and a physiological flow was generated using a commercial ventricular assist device (VAD). Monitored parameters, including pressure, tube distension and downstream velocity, acquired using time-resolved particle imaging velocimetry (PIV), were applied to an unsteady Bernoulli analysis of the flow in a novel way to evaluate pump performance as a proxy for cardiac workload. When compared to the rigid case, the compliant mock aorta case demonstrated healthier physiologic pressure waveforms, steadier downstream flow and reduced energetic demands on the pump. These results provide experimental verification of Windkessel theory and support the need for a compliant mock aorta in the EVHP system. Public Library of Science 2020-10-12 /pmc/articles/PMC7549783/ /pubmed/33044976 http://dx.doi.org/10.1371/journal.pone.0239604 Text en © 2020 Cameron et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Cameron, Katie
El Hassan, Mouhammad
Sabbagh, Reza
Freed, Darren H.
Nobes, David S.
Experimental investigation into the effect of compliance of a mock aorta on cardiac performance
title Experimental investigation into the effect of compliance of a mock aorta on cardiac performance
title_full Experimental investigation into the effect of compliance of a mock aorta on cardiac performance
title_fullStr Experimental investigation into the effect of compliance of a mock aorta on cardiac performance
title_full_unstemmed Experimental investigation into the effect of compliance of a mock aorta on cardiac performance
title_short Experimental investigation into the effect of compliance of a mock aorta on cardiac performance
title_sort experimental investigation into the effect of compliance of a mock aorta on cardiac performance
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7549783/
https://www.ncbi.nlm.nih.gov/pubmed/33044976
http://dx.doi.org/10.1371/journal.pone.0239604
work_keys_str_mv AT cameronkatie experimentalinvestigationintotheeffectofcomplianceofamockaortaoncardiacperformance
AT elhassanmouhammad experimentalinvestigationintotheeffectofcomplianceofamockaortaoncardiacperformance
AT sabbaghreza experimentalinvestigationintotheeffectofcomplianceofamockaortaoncardiacperformance
AT freeddarrenh experimentalinvestigationintotheeffectofcomplianceofamockaortaoncardiacperformance
AT nobesdavids experimentalinvestigationintotheeffectofcomplianceofamockaortaoncardiacperformance