Comparison of waveform-derived corneal stiffness and stress-strain extensometry-derived corneal stiffness using different cross-linking irradiances: an experimental study with air-puff applanation of ex vivo porcine eyes

PURPOSE: To assess corneal stiffening of standard (S-CXL) and accelerated (A-CXL) cross-linking protocols by dynamic corneal response parameters and corneal bending stiffness (Kc[mean/linear]) derived from Corvis (CVS) Scheimpflug-based tonometry. These investigations were validated by corneal tensi...

Descripción completa

Detalles Bibliográficos
Autores principales: Herber, Robert, Francis, Mathew, Spoerl, Eberhard, Pillunat, Lutz E., Raiskup, Frederik, Sinha Roy, Abhijit
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7550374/
https://www.ncbi.nlm.nih.gov/pubmed/32556637
http://dx.doi.org/10.1007/s00417-020-04792-8
_version_ 1783592962753560576
author Herber, Robert
Francis, Mathew
Spoerl, Eberhard
Pillunat, Lutz E.
Raiskup, Frederik
Sinha Roy, Abhijit
author_facet Herber, Robert
Francis, Mathew
Spoerl, Eberhard
Pillunat, Lutz E.
Raiskup, Frederik
Sinha Roy, Abhijit
author_sort Herber, Robert
collection PubMed
description PURPOSE: To assess corneal stiffening of standard (S-CXL) and accelerated (A-CXL) cross-linking protocols by dynamic corneal response parameters and corneal bending stiffness (Kc[mean/linear]) derived from Corvis (CVS) Scheimpflug-based tonometry. These investigations were validated by corneal tensile stiffness (K[ts]), derived from stress-strain extensometry in ex vivo porcine eyes. METHODS: Seventy-two fresh-enucleated and de-epithelized porcine eyes were soaked in 0.1% riboflavin solution including 10% dextran for 10 min. The eyes were separated into four groups: controls (n = 18), S-CXL (intensity in mW/cm(2)*time in min; 3*30) (n = 18), A-CXL (9*10) (n = 18), and A-CXL (18*5) (n = 18), respectively. CXL was performed using CCL Vario. CVS measurements were performed on all eyes. Subsequently, corneal strips were extracted by a double-bladed scalpel and used for stress-strain measurements. K[ts] was calculated from a force-displacement curve. Mean corneal stiffness (Kc[mean]) and constant corneal stiffness (Kc[linear]) were calculated from raw CVS data. RESULTS: In CVS, biomechanical effects of cross-linking were shown to have a significantly decreased deflection amplitude as well as integrated radius, an increased IOP, and SP A1 (P < 0.05). Kc[mean]/Kc[linear] were significantly increased after CXL (P < 0.05). In the range from 2 to 6% strain, K[ts] was significantly higher in S-CXL (3*30) compared to A-CXL (9*10), A-CXL (18*5), and controls (P < 0.05). At 8% to 10% strain, all protocols induced a higher stiffness than controls (P < 0.05). CONCLUSION: Several CVS parameters and Kc[mean] as well as Kc[linear] verify corneal stiffening effect after CXL on porcine eyes. S-CXL seems to have a higher tendency of stiffening than A-CXL protocols have, which was demonstrated by Scheimpflug-based tonometry and stress-strain extensometry.
format Online
Article
Text
id pubmed-7550374
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-75503742020-10-19 Comparison of waveform-derived corneal stiffness and stress-strain extensometry-derived corneal stiffness using different cross-linking irradiances: an experimental study with air-puff applanation of ex vivo porcine eyes Herber, Robert Francis, Mathew Spoerl, Eberhard Pillunat, Lutz E. Raiskup, Frederik Sinha Roy, Abhijit Graefes Arch Clin Exp Ophthalmol Basic Science PURPOSE: To assess corneal stiffening of standard (S-CXL) and accelerated (A-CXL) cross-linking protocols by dynamic corneal response parameters and corneal bending stiffness (Kc[mean/linear]) derived from Corvis (CVS) Scheimpflug-based tonometry. These investigations were validated by corneal tensile stiffness (K[ts]), derived from stress-strain extensometry in ex vivo porcine eyes. METHODS: Seventy-two fresh-enucleated and de-epithelized porcine eyes were soaked in 0.1% riboflavin solution including 10% dextran for 10 min. The eyes were separated into four groups: controls (n = 18), S-CXL (intensity in mW/cm(2)*time in min; 3*30) (n = 18), A-CXL (9*10) (n = 18), and A-CXL (18*5) (n = 18), respectively. CXL was performed using CCL Vario. CVS measurements were performed on all eyes. Subsequently, corneal strips were extracted by a double-bladed scalpel and used for stress-strain measurements. K[ts] was calculated from a force-displacement curve. Mean corneal stiffness (Kc[mean]) and constant corneal stiffness (Kc[linear]) were calculated from raw CVS data. RESULTS: In CVS, biomechanical effects of cross-linking were shown to have a significantly decreased deflection amplitude as well as integrated radius, an increased IOP, and SP A1 (P < 0.05). Kc[mean]/Kc[linear] were significantly increased after CXL (P < 0.05). In the range from 2 to 6% strain, K[ts] was significantly higher in S-CXL (3*30) compared to A-CXL (9*10), A-CXL (18*5), and controls (P < 0.05). At 8% to 10% strain, all protocols induced a higher stiffness than controls (P < 0.05). CONCLUSION: Several CVS parameters and Kc[mean] as well as Kc[linear] verify corneal stiffening effect after CXL on porcine eyes. S-CXL seems to have a higher tendency of stiffening than A-CXL protocols have, which was demonstrated by Scheimpflug-based tonometry and stress-strain extensometry. Springer Berlin Heidelberg 2020-06-17 2020 /pmc/articles/PMC7550374/ /pubmed/32556637 http://dx.doi.org/10.1007/s00417-020-04792-8 Text en © The Author(s) 2020 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Basic Science
Herber, Robert
Francis, Mathew
Spoerl, Eberhard
Pillunat, Lutz E.
Raiskup, Frederik
Sinha Roy, Abhijit
Comparison of waveform-derived corneal stiffness and stress-strain extensometry-derived corneal stiffness using different cross-linking irradiances: an experimental study with air-puff applanation of ex vivo porcine eyes
title Comparison of waveform-derived corneal stiffness and stress-strain extensometry-derived corneal stiffness using different cross-linking irradiances: an experimental study with air-puff applanation of ex vivo porcine eyes
title_full Comparison of waveform-derived corneal stiffness and stress-strain extensometry-derived corneal stiffness using different cross-linking irradiances: an experimental study with air-puff applanation of ex vivo porcine eyes
title_fullStr Comparison of waveform-derived corneal stiffness and stress-strain extensometry-derived corneal stiffness using different cross-linking irradiances: an experimental study with air-puff applanation of ex vivo porcine eyes
title_full_unstemmed Comparison of waveform-derived corneal stiffness and stress-strain extensometry-derived corneal stiffness using different cross-linking irradiances: an experimental study with air-puff applanation of ex vivo porcine eyes
title_short Comparison of waveform-derived corneal stiffness and stress-strain extensometry-derived corneal stiffness using different cross-linking irradiances: an experimental study with air-puff applanation of ex vivo porcine eyes
title_sort comparison of waveform-derived corneal stiffness and stress-strain extensometry-derived corneal stiffness using different cross-linking irradiances: an experimental study with air-puff applanation of ex vivo porcine eyes
topic Basic Science
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7550374/
https://www.ncbi.nlm.nih.gov/pubmed/32556637
http://dx.doi.org/10.1007/s00417-020-04792-8
work_keys_str_mv AT herberrobert comparisonofwaveformderivedcornealstiffnessandstressstrainextensometryderivedcornealstiffnessusingdifferentcrosslinkingirradiancesanexperimentalstudywithairpuffapplanationofexvivoporcineeyes
AT francismathew comparisonofwaveformderivedcornealstiffnessandstressstrainextensometryderivedcornealstiffnessusingdifferentcrosslinkingirradiancesanexperimentalstudywithairpuffapplanationofexvivoporcineeyes
AT spoerleberhard comparisonofwaveformderivedcornealstiffnessandstressstrainextensometryderivedcornealstiffnessusingdifferentcrosslinkingirradiancesanexperimentalstudywithairpuffapplanationofexvivoporcineeyes
AT pillunatlutze comparisonofwaveformderivedcornealstiffnessandstressstrainextensometryderivedcornealstiffnessusingdifferentcrosslinkingirradiancesanexperimentalstudywithairpuffapplanationofexvivoporcineeyes
AT raiskupfrederik comparisonofwaveformderivedcornealstiffnessandstressstrainextensometryderivedcornealstiffnessusingdifferentcrosslinkingirradiancesanexperimentalstudywithairpuffapplanationofexvivoporcineeyes
AT sinharoyabhijit comparisonofwaveformderivedcornealstiffnessandstressstrainextensometryderivedcornealstiffnessusingdifferentcrosslinkingirradiancesanexperimentalstudywithairpuffapplanationofexvivoporcineeyes