Cargando…

A Preliminary Simulation Study of Dose-Guided Adaptive Radiotherapy Based on Halcyon MV Cone-Beam CT Images With Retrospective Data From a Phase II Clinical Trial

Background and purpose: To evaluate the feasibility of dose-guided adaptive radiotherapy (ART) based on deformable image registration (DIR) using fractional megavoltage cone-beam CT (MVCBCT) images from Halcyon system that uses identical beams for treatment and imaging and to retrospectively investi...

Descripción completa

Detalles Bibliográficos
Autores principales: Huang, Yuliang, Wang, Haiyang, Li, Chenguang, Hu, Qiaoqiao, Liu, Hongjia, Deng, Jun, Li, Weibo, Wang, Ruoxi, Wu, Hao, Zhang, Yibao
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7550711/
https://www.ncbi.nlm.nih.gov/pubmed/33134173
http://dx.doi.org/10.3389/fonc.2020.574889
_version_ 1783593023925387264
author Huang, Yuliang
Wang, Haiyang
Li, Chenguang
Hu, Qiaoqiao
Liu, Hongjia
Deng, Jun
Li, Weibo
Wang, Ruoxi
Wu, Hao
Zhang, Yibao
author_facet Huang, Yuliang
Wang, Haiyang
Li, Chenguang
Hu, Qiaoqiao
Liu, Hongjia
Deng, Jun
Li, Weibo
Wang, Ruoxi
Wu, Hao
Zhang, Yibao
author_sort Huang, Yuliang
collection PubMed
description Background and purpose: To evaluate the feasibility of dose-guided adaptive radiotherapy (ART) based on deformable image registration (DIR) using fractional megavoltage cone-beam CT (MVCBCT) images from Halcyon system that uses identical beams for treatment and imaging and to retrospectively investigate the influence of anatomic changes on target coverage and organ-at-risk (OAR) sparing across various tumor sites. Materials and Methods: Four hundred twenty-two MVCBCT images from 16 patients (three head and neck, seven thoracic, three abdominal, and three pelvic cases) treated in a phase II clinical trial for Halcyon were selected. DIR between the planning CT and daily MVCBCT image was implemented by Velocity software to create pseudo CT. To investigate the accuracy of dose calculation on pseudo CT, three evaluation patients with rescanned CT and adaptive plans were selected. Dose distribution of adaptive plans calculated on pseudo CT was compared with that calculated on the rescanned planning CT on the three evaluation patients. To investigate the impact of inter-fractional anatomic changes on target dose coverage and dose to OARs of the 16 patients, fractional dose was calculated and accumulated incrementally based on deformable registration between planning CT and daily MVCBCT images. Results: Passing rates using 3 mm/3%/10% threshold local gamma analysis were 93.04, 96.00, and 91.68%, respectively, for the three evaluation patients between the reconstructed dose on pseudo CT (MVCBCT) and rescanned CT, where accumulated dose deviations of over 97% voxels were smaller than 0.5 Gy. Planning target volume (PTV) D95% and D90% (the minimum dose received by at least 95/90% of the volume) of the accumulated dose could be as low as 93.8 and 94.5% of the planned dose, respectively. OAR overdose of various degrees were observed in the 16 patients relative to the planned dose. In most cases, OARs' dose volume histogram (DVH) lines of accumulated and planned dose were very close to each other if not overlapping. Among cases with visible deviations, the differences were bilateral without apparent patterns specific to tumor sites or organs. Conclusion: As a confidence building measure, this simulation study suggested the possibility of ART for Halcyon based on DIR between planning CT and MVCBCT. Preliminary clinical data suggested the benefit of patient-specific dose reconstruction and ART to avoid unacceptable target underdosage and OAR overdosage.
format Online
Article
Text
id pubmed-7550711
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-75507112020-10-29 A Preliminary Simulation Study of Dose-Guided Adaptive Radiotherapy Based on Halcyon MV Cone-Beam CT Images With Retrospective Data From a Phase II Clinical Trial Huang, Yuliang Wang, Haiyang Li, Chenguang Hu, Qiaoqiao Liu, Hongjia Deng, Jun Li, Weibo Wang, Ruoxi Wu, Hao Zhang, Yibao Front Oncol Oncology Background and purpose: To evaluate the feasibility of dose-guided adaptive radiotherapy (ART) based on deformable image registration (DIR) using fractional megavoltage cone-beam CT (MVCBCT) images from Halcyon system that uses identical beams for treatment and imaging and to retrospectively investigate the influence of anatomic changes on target coverage and organ-at-risk (OAR) sparing across various tumor sites. Materials and Methods: Four hundred twenty-two MVCBCT images from 16 patients (three head and neck, seven thoracic, three abdominal, and three pelvic cases) treated in a phase II clinical trial for Halcyon were selected. DIR between the planning CT and daily MVCBCT image was implemented by Velocity software to create pseudo CT. To investigate the accuracy of dose calculation on pseudo CT, three evaluation patients with rescanned CT and adaptive plans were selected. Dose distribution of adaptive plans calculated on pseudo CT was compared with that calculated on the rescanned planning CT on the three evaluation patients. To investigate the impact of inter-fractional anatomic changes on target dose coverage and dose to OARs of the 16 patients, fractional dose was calculated and accumulated incrementally based on deformable registration between planning CT and daily MVCBCT images. Results: Passing rates using 3 mm/3%/10% threshold local gamma analysis were 93.04, 96.00, and 91.68%, respectively, for the three evaluation patients between the reconstructed dose on pseudo CT (MVCBCT) and rescanned CT, where accumulated dose deviations of over 97% voxels were smaller than 0.5 Gy. Planning target volume (PTV) D95% and D90% (the minimum dose received by at least 95/90% of the volume) of the accumulated dose could be as low as 93.8 and 94.5% of the planned dose, respectively. OAR overdose of various degrees were observed in the 16 patients relative to the planned dose. In most cases, OARs' dose volume histogram (DVH) lines of accumulated and planned dose were very close to each other if not overlapping. Among cases with visible deviations, the differences were bilateral without apparent patterns specific to tumor sites or organs. Conclusion: As a confidence building measure, this simulation study suggested the possibility of ART for Halcyon based on DIR between planning CT and MVCBCT. Preliminary clinical data suggested the benefit of patient-specific dose reconstruction and ART to avoid unacceptable target underdosage and OAR overdosage. Frontiers Media S.A. 2020-09-29 /pmc/articles/PMC7550711/ /pubmed/33134173 http://dx.doi.org/10.3389/fonc.2020.574889 Text en Copyright © 2020 Huang, Wang, Li, Hu, Liu, Deng, Li, Wang, Wu and Zhang. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Oncology
Huang, Yuliang
Wang, Haiyang
Li, Chenguang
Hu, Qiaoqiao
Liu, Hongjia
Deng, Jun
Li, Weibo
Wang, Ruoxi
Wu, Hao
Zhang, Yibao
A Preliminary Simulation Study of Dose-Guided Adaptive Radiotherapy Based on Halcyon MV Cone-Beam CT Images With Retrospective Data From a Phase II Clinical Trial
title A Preliminary Simulation Study of Dose-Guided Adaptive Radiotherapy Based on Halcyon MV Cone-Beam CT Images With Retrospective Data From a Phase II Clinical Trial
title_full A Preliminary Simulation Study of Dose-Guided Adaptive Radiotherapy Based on Halcyon MV Cone-Beam CT Images With Retrospective Data From a Phase II Clinical Trial
title_fullStr A Preliminary Simulation Study of Dose-Guided Adaptive Radiotherapy Based on Halcyon MV Cone-Beam CT Images With Retrospective Data From a Phase II Clinical Trial
title_full_unstemmed A Preliminary Simulation Study of Dose-Guided Adaptive Radiotherapy Based on Halcyon MV Cone-Beam CT Images With Retrospective Data From a Phase II Clinical Trial
title_short A Preliminary Simulation Study of Dose-Guided Adaptive Radiotherapy Based on Halcyon MV Cone-Beam CT Images With Retrospective Data From a Phase II Clinical Trial
title_sort preliminary simulation study of dose-guided adaptive radiotherapy based on halcyon mv cone-beam ct images with retrospective data from a phase ii clinical trial
topic Oncology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7550711/
https://www.ncbi.nlm.nih.gov/pubmed/33134173
http://dx.doi.org/10.3389/fonc.2020.574889
work_keys_str_mv AT huangyuliang apreliminarysimulationstudyofdoseguidedadaptiveradiotherapybasedonhalcyonmvconebeamctimageswithretrospectivedatafromaphaseiiclinicaltrial
AT wanghaiyang apreliminarysimulationstudyofdoseguidedadaptiveradiotherapybasedonhalcyonmvconebeamctimageswithretrospectivedatafromaphaseiiclinicaltrial
AT lichenguang apreliminarysimulationstudyofdoseguidedadaptiveradiotherapybasedonhalcyonmvconebeamctimageswithretrospectivedatafromaphaseiiclinicaltrial
AT huqiaoqiao apreliminarysimulationstudyofdoseguidedadaptiveradiotherapybasedonhalcyonmvconebeamctimageswithretrospectivedatafromaphaseiiclinicaltrial
AT liuhongjia apreliminarysimulationstudyofdoseguidedadaptiveradiotherapybasedonhalcyonmvconebeamctimageswithretrospectivedatafromaphaseiiclinicaltrial
AT dengjun apreliminarysimulationstudyofdoseguidedadaptiveradiotherapybasedonhalcyonmvconebeamctimageswithretrospectivedatafromaphaseiiclinicaltrial
AT liweibo apreliminarysimulationstudyofdoseguidedadaptiveradiotherapybasedonhalcyonmvconebeamctimageswithretrospectivedatafromaphaseiiclinicaltrial
AT wangruoxi apreliminarysimulationstudyofdoseguidedadaptiveradiotherapybasedonhalcyonmvconebeamctimageswithretrospectivedatafromaphaseiiclinicaltrial
AT wuhao apreliminarysimulationstudyofdoseguidedadaptiveradiotherapybasedonhalcyonmvconebeamctimageswithretrospectivedatafromaphaseiiclinicaltrial
AT zhangyibao apreliminarysimulationstudyofdoseguidedadaptiveradiotherapybasedonhalcyonmvconebeamctimageswithretrospectivedatafromaphaseiiclinicaltrial
AT huangyuliang preliminarysimulationstudyofdoseguidedadaptiveradiotherapybasedonhalcyonmvconebeamctimageswithretrospectivedatafromaphaseiiclinicaltrial
AT wanghaiyang preliminarysimulationstudyofdoseguidedadaptiveradiotherapybasedonhalcyonmvconebeamctimageswithretrospectivedatafromaphaseiiclinicaltrial
AT lichenguang preliminarysimulationstudyofdoseguidedadaptiveradiotherapybasedonhalcyonmvconebeamctimageswithretrospectivedatafromaphaseiiclinicaltrial
AT huqiaoqiao preliminarysimulationstudyofdoseguidedadaptiveradiotherapybasedonhalcyonmvconebeamctimageswithretrospectivedatafromaphaseiiclinicaltrial
AT liuhongjia preliminarysimulationstudyofdoseguidedadaptiveradiotherapybasedonhalcyonmvconebeamctimageswithretrospectivedatafromaphaseiiclinicaltrial
AT dengjun preliminarysimulationstudyofdoseguidedadaptiveradiotherapybasedonhalcyonmvconebeamctimageswithretrospectivedatafromaphaseiiclinicaltrial
AT liweibo preliminarysimulationstudyofdoseguidedadaptiveradiotherapybasedonhalcyonmvconebeamctimageswithretrospectivedatafromaphaseiiclinicaltrial
AT wangruoxi preliminarysimulationstudyofdoseguidedadaptiveradiotherapybasedonhalcyonmvconebeamctimageswithretrospectivedatafromaphaseiiclinicaltrial
AT wuhao preliminarysimulationstudyofdoseguidedadaptiveradiotherapybasedonhalcyonmvconebeamctimageswithretrospectivedatafromaphaseiiclinicaltrial
AT zhangyibao preliminarysimulationstudyofdoseguidedadaptiveradiotherapybasedonhalcyonmvconebeamctimageswithretrospectivedatafromaphaseiiclinicaltrial