Hemodynamic Performance of Dysfunctional Prosthetic Heart Valve with the Concomitant Presence of Subaortic Stenosis: In Silico Study

The prosthetic heart valve is vulnerable to dysfunction after surgery, thus a frequent assessment is required. Doppler electrocardiography and its quantitative parameters are commonly used to assess the performance of the prosthetic heart valves and provide detailed information on the interaction be...

Descripción completa

Detalles Bibliográficos
Autores principales: Smadi, Othman, Abdelkarim, Anas, Awad, Samer, D. Almomani, Thakir
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7552677/
https://www.ncbi.nlm.nih.gov/pubmed/32784661
http://dx.doi.org/10.3390/bioengineering7030090
_version_ 1783593452625199104
author Smadi, Othman
Abdelkarim, Anas
Awad, Samer
D. Almomani, Thakir
author_facet Smadi, Othman
Abdelkarim, Anas
Awad, Samer
D. Almomani, Thakir
author_sort Smadi, Othman
collection PubMed
description The prosthetic heart valve is vulnerable to dysfunction after surgery, thus a frequent assessment is required. Doppler electrocardiography and its quantitative parameters are commonly used to assess the performance of the prosthetic heart valves and provide detailed information on the interaction between the heart chambers and related prosthetic valves, allowing early detection of complications. However, in the case of the presence of subaortic stenosis, the accuracy of Doppler has not been fully investigated in previous studies and guidelines. Therefore, it is important to evaluate the accuracy of the parameters in such cases to get early detection, and a proper treatment plan for the patient, at the right time. In the current study, a CFD simulation was performed for the blood flow through a Bileaflet Mechanical Heart Valve (BMHV) with concomitant obstruction in the Left Ventricle Outflow Tract (LVOT). The current study explores the impact of the presence of the subaortic on flow patterns. It also investigates the accuracy of (BMHV) evaluation using Doppler parameters, as proposed in the American Society of Echocardiography (ASE) guidelines.
format Online
Article
Text
id pubmed-7552677
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-75526772020-10-19 Hemodynamic Performance of Dysfunctional Prosthetic Heart Valve with the Concomitant Presence of Subaortic Stenosis: In Silico Study Smadi, Othman Abdelkarim, Anas Awad, Samer D. Almomani, Thakir Bioengineering (Basel) Article The prosthetic heart valve is vulnerable to dysfunction after surgery, thus a frequent assessment is required. Doppler electrocardiography and its quantitative parameters are commonly used to assess the performance of the prosthetic heart valves and provide detailed information on the interaction between the heart chambers and related prosthetic valves, allowing early detection of complications. However, in the case of the presence of subaortic stenosis, the accuracy of Doppler has not been fully investigated in previous studies and guidelines. Therefore, it is important to evaluate the accuracy of the parameters in such cases to get early detection, and a proper treatment plan for the patient, at the right time. In the current study, a CFD simulation was performed for the blood flow through a Bileaflet Mechanical Heart Valve (BMHV) with concomitant obstruction in the Left Ventricle Outflow Tract (LVOT). The current study explores the impact of the presence of the subaortic on flow patterns. It also investigates the accuracy of (BMHV) evaluation using Doppler parameters, as proposed in the American Society of Echocardiography (ASE) guidelines. MDPI 2020-08-07 /pmc/articles/PMC7552677/ /pubmed/32784661 http://dx.doi.org/10.3390/bioengineering7030090 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Smadi, Othman
Abdelkarim, Anas
Awad, Samer
D. Almomani, Thakir
Hemodynamic Performance of Dysfunctional Prosthetic Heart Valve with the Concomitant Presence of Subaortic Stenosis: In Silico Study
title Hemodynamic Performance of Dysfunctional Prosthetic Heart Valve with the Concomitant Presence of Subaortic Stenosis: In Silico Study
title_full Hemodynamic Performance of Dysfunctional Prosthetic Heart Valve with the Concomitant Presence of Subaortic Stenosis: In Silico Study
title_fullStr Hemodynamic Performance of Dysfunctional Prosthetic Heart Valve with the Concomitant Presence of Subaortic Stenosis: In Silico Study
title_full_unstemmed Hemodynamic Performance of Dysfunctional Prosthetic Heart Valve with the Concomitant Presence of Subaortic Stenosis: In Silico Study
title_short Hemodynamic Performance of Dysfunctional Prosthetic Heart Valve with the Concomitant Presence of Subaortic Stenosis: In Silico Study
title_sort hemodynamic performance of dysfunctional prosthetic heart valve with the concomitant presence of subaortic stenosis: in silico study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7552677/
https://www.ncbi.nlm.nih.gov/pubmed/32784661
http://dx.doi.org/10.3390/bioengineering7030090
work_keys_str_mv AT smadiothman hemodynamicperformanceofdysfunctionalprostheticheartvalvewiththeconcomitantpresenceofsubaorticstenosisinsilicostudy
AT abdelkarimanas hemodynamicperformanceofdysfunctionalprostheticheartvalvewiththeconcomitantpresenceofsubaorticstenosisinsilicostudy
AT awadsamer hemodynamicperformanceofdysfunctionalprostheticheartvalvewiththeconcomitantpresenceofsubaorticstenosisinsilicostudy
AT dalmomanithakir hemodynamicperformanceofdysfunctionalprostheticheartvalvewiththeconcomitantpresenceofsubaorticstenosisinsilicostudy