Cargando…

Quantitative Comparison of the Vascular Structure of Macular Neovascularizations Between Swept-Source and Spectral-Domain Optical Coherence Tomography Angiography

PURPOSE: The aim of this study was to ascertain and quantify the differences between swept-source (SS) and spectral-domain (SD) optical coherence tomography angiography (OCTA) imaging of macular neovascularizations (MNV) in neovascular age-related macular degeneration (nAMD). PATIENTS AND METHODS: S...

Descripción completa

Detalles Bibliográficos
Autores principales: Faatz, Henrik, Rothaus, Kai, Ziegler, Martin, Book, Marius, Lommatzsch, Claudia, Spital, Georg, Gutfleisch, Matthias, Pauleikhoff, Daniel, Lommatzsch, Albrecht
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7553257/
https://www.ncbi.nlm.nih.gov/pubmed/33116368
http://dx.doi.org/10.2147/OPTH.S276114
Descripción
Sumario:PURPOSE: The aim of this study was to ascertain and quantify the differences between swept-source (SS) and spectral-domain (SD) optical coherence tomography angiography (OCTA) imaging of macular neovascularizations (MNV) in neovascular age-related macular degeneration (nAMD). PATIENTS AND METHODS: SD-OCTA (RTVue Avanti) and SS-OCTA (PLEX(®) Elite 9000) were performed in 37 patients with MNV in nAMD. The MNV was delineated and the data were processed via ImageJ. The parameters MNV area, nodes per area, fractal dimension (FD), and flow density were analyzed using MatLab. RESULTS: There was close agreement between the two devices regarding MNV area (ICCc 0.977, ICCa 0.977, R(2) 0.977), but only slight agreement regarding nodes per area (ICCa 0.008, ICCc 0.548, R(2) 0.51), FD (ICCa 0.425, ICCc 0.846, R(2) 0.96), and flow density (ICCa 0.451, ICCc 0.656, R(2) 0.65). The difference between the two devices was insignificant for MNV area (type 1: p=0.328; type 2: p=0.426; type 3: p=0.615), but significant for nodes per area (type 1: p=0.002; type 2: p=0.00001; type 3: p=0.003), FD (type 1: p<0.00001; type 2: p<0.00001; type 3: p=0.015) and flow density (type 1: p=0.0004; type 2: p=0.004; type 3: p=0.052). CONCLUSION: MNV area is closely comparable between devices using SS-OCTA and SD-OCTA imaging. However, the two methods differ significantly in their precise assessment of the vascular morphology (FD, flow density, nodes per area). Therefore, results obtained using different devices are not comparable and should not be amalgamated in clinical trials.