Compressed Sensing MR Imaging (CS-MRI) of the Knee: Assessment of Quality, Inter-reader Agreement, and Acquisition Time

We compared 3 Tesla (3T) compressed sensing (CS)-MRI of different pulse sequences with various acceleration factors to standard fast spin-echo (FSE) sequences in terms of time, quality, and inter-reader agreement. Each sequence was qualitatively ranked and then qualitatively scored for blurring, art...

Descripción completa

Detalles Bibliográficos
Autores principales: Matcuk, George R., Gross, Jordan S., Fields, Brandon K.K., Cen, Steven
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Japanese Society for Magnetic Resonance in Medicine 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7553806/
https://www.ncbi.nlm.nih.gov/pubmed/31548480
http://dx.doi.org/10.2463/mrms.tn.2019-0095
_version_ 1783593677995638784
author Matcuk, George R.
Gross, Jordan S.
Fields, Brandon K.K.
Cen, Steven
author_facet Matcuk, George R.
Gross, Jordan S.
Fields, Brandon K.K.
Cen, Steven
author_sort Matcuk, George R.
collection PubMed
description We compared 3 Tesla (3T) compressed sensing (CS)-MRI of different pulse sequences with various acceleration factors to standard fast spin-echo (FSE) sequences in terms of time, quality, and inter-reader agreement. Each sequence was qualitatively ranked and then qualitatively scored for blurring, artifact, low contrast detection, noise pattern, signal-to-noise ratio, and overall quality. The CS-MRI sequences demonstrated very good overall quality compared with routine FSE sequences with overall good inter-reader agreement.
format Online
Article
Text
id pubmed-7553806
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Japanese Society for Magnetic Resonance in Medicine
record_format MEDLINE/PubMed
spelling pubmed-75538062020-10-26 Compressed Sensing MR Imaging (CS-MRI) of the Knee: Assessment of Quality, Inter-reader Agreement, and Acquisition Time Matcuk, George R. Gross, Jordan S. Fields, Brandon K.K. Cen, Steven Magn Reson Med Sci Technical Note We compared 3 Tesla (3T) compressed sensing (CS)-MRI of different pulse sequences with various acceleration factors to standard fast spin-echo (FSE) sequences in terms of time, quality, and inter-reader agreement. Each sequence was qualitatively ranked and then qualitatively scored for blurring, artifact, low contrast detection, noise pattern, signal-to-noise ratio, and overall quality. The CS-MRI sequences demonstrated very good overall quality compared with routine FSE sequences with overall good inter-reader agreement. Japanese Society for Magnetic Resonance in Medicine 2019-09-24 /pmc/articles/PMC7553806/ /pubmed/31548480 http://dx.doi.org/10.2463/mrms.tn.2019-0095 Text en © 2019 Japanese Society for Magnetic Resonance in Medicine This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. To view a copy of this license, visit http://creativecommons.org/licenses/by-nc-nd/4.0/
spellingShingle Technical Note
Matcuk, George R.
Gross, Jordan S.
Fields, Brandon K.K.
Cen, Steven
Compressed Sensing MR Imaging (CS-MRI) of the Knee: Assessment of Quality, Inter-reader Agreement, and Acquisition Time
title Compressed Sensing MR Imaging (CS-MRI) of the Knee: Assessment of Quality, Inter-reader Agreement, and Acquisition Time
title_full Compressed Sensing MR Imaging (CS-MRI) of the Knee: Assessment of Quality, Inter-reader Agreement, and Acquisition Time
title_fullStr Compressed Sensing MR Imaging (CS-MRI) of the Knee: Assessment of Quality, Inter-reader Agreement, and Acquisition Time
title_full_unstemmed Compressed Sensing MR Imaging (CS-MRI) of the Knee: Assessment of Quality, Inter-reader Agreement, and Acquisition Time
title_short Compressed Sensing MR Imaging (CS-MRI) of the Knee: Assessment of Quality, Inter-reader Agreement, and Acquisition Time
title_sort compressed sensing mr imaging (cs-mri) of the knee: assessment of quality, inter-reader agreement, and acquisition time
topic Technical Note
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7553806/
https://www.ncbi.nlm.nih.gov/pubmed/31548480
http://dx.doi.org/10.2463/mrms.tn.2019-0095
work_keys_str_mv AT matcukgeorger compressedsensingmrimagingcsmriofthekneeassessmentofqualityinterreaderagreementandacquisitiontime
AT grossjordans compressedsensingmrimagingcsmriofthekneeassessmentofqualityinterreaderagreementandacquisitiontime
AT fieldsbrandonkk compressedsensingmrimagingcsmriofthekneeassessmentofqualityinterreaderagreementandacquisitiontime
AT censteven compressedsensingmrimagingcsmriofthekneeassessmentofqualityinterreaderagreementandacquisitiontime