Establishment of CTPA Local Diagnostic Reference Levels with Noise Magnitude as a Quality Indicator in a Tertiary Care Hospital

This study aimed to establish the local diagnostic reference levels (LDRLs) of computed tomography pulmonary angiography (CTPA) examinations based on body size with regard to noise magnitude as a quality indicator. The records of 127 patients (55 males and 72 females) who had undergone CTPAs using a...

Descripción completa

Detalles Bibliográficos
Autores principales: Harun, Hanif Haspi, Abdul Karim, Muhammad Khalis, Abd Rahman, Mohd Amiruddin, Abdul Razak, Hairil Rashmizal, Che Isa, Iza Nurzawani, Harun, Faeezah
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7555305/
https://www.ncbi.nlm.nih.gov/pubmed/32916913
http://dx.doi.org/10.3390/diagnostics10090680
_version_ 1783593976900616192
author Harun, Hanif Haspi
Abdul Karim, Muhammad Khalis
Abd Rahman, Mohd Amiruddin
Abdul Razak, Hairil Rashmizal
Che Isa, Iza Nurzawani
Harun, Faeezah
author_facet Harun, Hanif Haspi
Abdul Karim, Muhammad Khalis
Abd Rahman, Mohd Amiruddin
Abdul Razak, Hairil Rashmizal
Che Isa, Iza Nurzawani
Harun, Faeezah
author_sort Harun, Hanif Haspi
collection PubMed
description This study aimed to establish the local diagnostic reference levels (LDRLs) of computed tomography pulmonary angiography (CTPA) examinations based on body size with regard to noise magnitude as a quality indicator. The records of 127 patients (55 males and 72 females) who had undergone CTPAs using a 128-slice CT scanner were retrieved. The dose information, scanning acquisition parameters, and patient demographics were recorded in standardized forms. The body size of patients was categorized into three groups based on their anteroposterior body length: P1 (14–19 cm), P2 (19–24 cm), and P3 (24–31 cm), and the radiation dose exposure was statistically compared. The image noise was determined quantitatively by measuring the standard deviation of the region of interest (ROI) at five different arteries—the ascending and descending aorta, pulmonary trunk, and the left and right main pulmonary arteries. We observed that the LDRL values were significantly different between body sizes (p < 0.05), and the median values of the CT dose index volume (CTDI(vol)) for P1, P2, and P3 were 6.13, 8.3, and 21.40 mGy, respectively. It was noted that the noise reference values were 23.78, 24.26, and 23.97 HU for P1, P2, and P3, respectively, which were not significantly different from each other (p > 0.05). The CTDI(vol) of 9 mGy and dose length product (DLP) of 329 mGy∙cm in this study were lower than those reported by other studies conducted elsewhere. This study successfully established the LDRLs of a local healthcare institution with the inclusion of the noise magnitude, which is comparable with other established references.
format Online
Article
Text
id pubmed-7555305
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-75553052020-10-19 Establishment of CTPA Local Diagnostic Reference Levels with Noise Magnitude as a Quality Indicator in a Tertiary Care Hospital Harun, Hanif Haspi Abdul Karim, Muhammad Khalis Abd Rahman, Mohd Amiruddin Abdul Razak, Hairil Rashmizal Che Isa, Iza Nurzawani Harun, Faeezah Diagnostics (Basel) Article This study aimed to establish the local diagnostic reference levels (LDRLs) of computed tomography pulmonary angiography (CTPA) examinations based on body size with regard to noise magnitude as a quality indicator. The records of 127 patients (55 males and 72 females) who had undergone CTPAs using a 128-slice CT scanner were retrieved. The dose information, scanning acquisition parameters, and patient demographics were recorded in standardized forms. The body size of patients was categorized into three groups based on their anteroposterior body length: P1 (14–19 cm), P2 (19–24 cm), and P3 (24–31 cm), and the radiation dose exposure was statistically compared. The image noise was determined quantitatively by measuring the standard deviation of the region of interest (ROI) at five different arteries—the ascending and descending aorta, pulmonary trunk, and the left and right main pulmonary arteries. We observed that the LDRL values were significantly different between body sizes (p < 0.05), and the median values of the CT dose index volume (CTDI(vol)) for P1, P2, and P3 were 6.13, 8.3, and 21.40 mGy, respectively. It was noted that the noise reference values were 23.78, 24.26, and 23.97 HU for P1, P2, and P3, respectively, which were not significantly different from each other (p > 0.05). The CTDI(vol) of 9 mGy and dose length product (DLP) of 329 mGy∙cm in this study were lower than those reported by other studies conducted elsewhere. This study successfully established the LDRLs of a local healthcare institution with the inclusion of the noise magnitude, which is comparable with other established references. MDPI 2020-09-09 /pmc/articles/PMC7555305/ /pubmed/32916913 http://dx.doi.org/10.3390/diagnostics10090680 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Harun, Hanif Haspi
Abdul Karim, Muhammad Khalis
Abd Rahman, Mohd Amiruddin
Abdul Razak, Hairil Rashmizal
Che Isa, Iza Nurzawani
Harun, Faeezah
Establishment of CTPA Local Diagnostic Reference Levels with Noise Magnitude as a Quality Indicator in a Tertiary Care Hospital
title Establishment of CTPA Local Diagnostic Reference Levels with Noise Magnitude as a Quality Indicator in a Tertiary Care Hospital
title_full Establishment of CTPA Local Diagnostic Reference Levels with Noise Magnitude as a Quality Indicator in a Tertiary Care Hospital
title_fullStr Establishment of CTPA Local Diagnostic Reference Levels with Noise Magnitude as a Quality Indicator in a Tertiary Care Hospital
title_full_unstemmed Establishment of CTPA Local Diagnostic Reference Levels with Noise Magnitude as a Quality Indicator in a Tertiary Care Hospital
title_short Establishment of CTPA Local Diagnostic Reference Levels with Noise Magnitude as a Quality Indicator in a Tertiary Care Hospital
title_sort establishment of ctpa local diagnostic reference levels with noise magnitude as a quality indicator in a tertiary care hospital
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7555305/
https://www.ncbi.nlm.nih.gov/pubmed/32916913
http://dx.doi.org/10.3390/diagnostics10090680
work_keys_str_mv AT harunhanifhaspi establishmentofctpalocaldiagnosticreferencelevelswithnoisemagnitudeasaqualityindicatorinatertiarycarehospital
AT abdulkarimmuhammadkhalis establishmentofctpalocaldiagnosticreferencelevelswithnoisemagnitudeasaqualityindicatorinatertiarycarehospital
AT abdrahmanmohdamiruddin establishmentofctpalocaldiagnosticreferencelevelswithnoisemagnitudeasaqualityindicatorinatertiarycarehospital
AT abdulrazakhairilrashmizal establishmentofctpalocaldiagnosticreferencelevelswithnoisemagnitudeasaqualityindicatorinatertiarycarehospital
AT cheisaizanurzawani establishmentofctpalocaldiagnosticreferencelevelswithnoisemagnitudeasaqualityindicatorinatertiarycarehospital
AT harunfaeezah establishmentofctpalocaldiagnosticreferencelevelswithnoisemagnitudeasaqualityindicatorinatertiarycarehospital