Cargando…

Correlation Analysis of Refractive and Visual Quality after Wavefront-Optimized Laser In Situ Keratomileusis for 50% and 100% Angle Kappa Compensation

PURPOSE: To analyze the distribution of the offset between the pupil center and the coaxially sighted corneal light reflex (P-Dist), the effects of 50% and 100% angle kappa adjustments on refractive and visual quality in patients with moderate myopia were investigated. METHODS: A randomly selected 2...

Descripción completa

Detalles Bibliográficos
Autores principales: Ru, Xin-Yu, Li, Zheng-Ri, Li, Cheng-Lin, Cui, Hong, Deng, Wen-Qing, Lin, Shu-Hua, Jia, Yu-Jie, Li, Ying-Jun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7556047/
https://www.ncbi.nlm.nih.gov/pubmed/33083053
http://dx.doi.org/10.1155/2020/9873504
_version_ 1783594149752078336
author Ru, Xin-Yu
Li, Zheng-Ri
Li, Cheng-Lin
Cui, Hong
Deng, Wen-Qing
Lin, Shu-Hua
Jia, Yu-Jie
Li, Ying-Jun
author_facet Ru, Xin-Yu
Li, Zheng-Ri
Li, Cheng-Lin
Cui, Hong
Deng, Wen-Qing
Lin, Shu-Hua
Jia, Yu-Jie
Li, Ying-Jun
author_sort Ru, Xin-Yu
collection PubMed
description PURPOSE: To analyze the distribution of the offset between the pupil center and the coaxially sighted corneal light reflex (P-Dist), the effects of 50% and 100% angle kappa adjustments on refractive and visual quality in patients with moderate myopia were investigated. METHODS: A randomly selected 254 patients (254 eyes) with moderate myopia who underwent femtosecond laser-combined LASIK were examined. During the operation, the P-Dist of the patients was recorded by the x- and y-axis eyeball-tracking adjustment program of the WaveLight Eagle Vision EX500 excimer laser system. Preoperatively and 3 months postoperatively, the WaveLight® ALLEGRO Topolyzer was used to measure the pupil size and center position, and the wavefront sensor was used to measure the wavefront aberrations. The visual function tester (OPTEC 6500) measured contrast sensitivity. RESULTS: The average P-Dist was 0.220 ± 0.102 mm. When the P-Dist >0.220 mm, the postoperative residual cylinder was 0.29 ± 0.34 D in the group with the 50% adjustment and 0.40 ± 0.32 D in the 100% group, which was significantly higher than the 50% group (P=0.036). The coma was 0.21 ± 0.17 μm in the 50% adjusted group and 0.34 ± 0.25 μm in the 100% group, which was significantly higher than that in the 50% group (P=0.021). At the 1.5 c/d spatial frequency, contrast sensitivity in the adjusted 100% group was significantly lower than that in the 50% group under visual glare conditions (P=0.039). CONCLUSION: The postoperative visual acuity and spherical equivalent were not affected in the two groups. However, when P-Dist >0.220 mm, the residual astigmatism and coma were lower in the 50% group. Individualized operations for those with moderate myopia and large-angle kappa in which 100% adjustment is chosen may not result in a better visual quality effect than 50%.
format Online
Article
Text
id pubmed-7556047
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-75560472020-10-19 Correlation Analysis of Refractive and Visual Quality after Wavefront-Optimized Laser In Situ Keratomileusis for 50% and 100% Angle Kappa Compensation Ru, Xin-Yu Li, Zheng-Ri Li, Cheng-Lin Cui, Hong Deng, Wen-Qing Lin, Shu-Hua Jia, Yu-Jie Li, Ying-Jun J Ophthalmol Research Article PURPOSE: To analyze the distribution of the offset between the pupil center and the coaxially sighted corneal light reflex (P-Dist), the effects of 50% and 100% angle kappa adjustments on refractive and visual quality in patients with moderate myopia were investigated. METHODS: A randomly selected 254 patients (254 eyes) with moderate myopia who underwent femtosecond laser-combined LASIK were examined. During the operation, the P-Dist of the patients was recorded by the x- and y-axis eyeball-tracking adjustment program of the WaveLight Eagle Vision EX500 excimer laser system. Preoperatively and 3 months postoperatively, the WaveLight® ALLEGRO Topolyzer was used to measure the pupil size and center position, and the wavefront sensor was used to measure the wavefront aberrations. The visual function tester (OPTEC 6500) measured contrast sensitivity. RESULTS: The average P-Dist was 0.220 ± 0.102 mm. When the P-Dist >0.220 mm, the postoperative residual cylinder was 0.29 ± 0.34 D in the group with the 50% adjustment and 0.40 ± 0.32 D in the 100% group, which was significantly higher than the 50% group (P=0.036). The coma was 0.21 ± 0.17 μm in the 50% adjusted group and 0.34 ± 0.25 μm in the 100% group, which was significantly higher than that in the 50% group (P=0.021). At the 1.5 c/d spatial frequency, contrast sensitivity in the adjusted 100% group was significantly lower than that in the 50% group under visual glare conditions (P=0.039). CONCLUSION: The postoperative visual acuity and spherical equivalent were not affected in the two groups. However, when P-Dist >0.220 mm, the residual astigmatism and coma were lower in the 50% group. Individualized operations for those with moderate myopia and large-angle kappa in which 100% adjustment is chosen may not result in a better visual quality effect than 50%. Hindawi 2020-10-05 /pmc/articles/PMC7556047/ /pubmed/33083053 http://dx.doi.org/10.1155/2020/9873504 Text en Copyright © 2020 Xin-Yu Ru et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Ru, Xin-Yu
Li, Zheng-Ri
Li, Cheng-Lin
Cui, Hong
Deng, Wen-Qing
Lin, Shu-Hua
Jia, Yu-Jie
Li, Ying-Jun
Correlation Analysis of Refractive and Visual Quality after Wavefront-Optimized Laser In Situ Keratomileusis for 50% and 100% Angle Kappa Compensation
title Correlation Analysis of Refractive and Visual Quality after Wavefront-Optimized Laser In Situ Keratomileusis for 50% and 100% Angle Kappa Compensation
title_full Correlation Analysis of Refractive and Visual Quality after Wavefront-Optimized Laser In Situ Keratomileusis for 50% and 100% Angle Kappa Compensation
title_fullStr Correlation Analysis of Refractive and Visual Quality after Wavefront-Optimized Laser In Situ Keratomileusis for 50% and 100% Angle Kappa Compensation
title_full_unstemmed Correlation Analysis of Refractive and Visual Quality after Wavefront-Optimized Laser In Situ Keratomileusis for 50% and 100% Angle Kappa Compensation
title_short Correlation Analysis of Refractive and Visual Quality after Wavefront-Optimized Laser In Situ Keratomileusis for 50% and 100% Angle Kappa Compensation
title_sort correlation analysis of refractive and visual quality after wavefront-optimized laser in situ keratomileusis for 50% and 100% angle kappa compensation
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7556047/
https://www.ncbi.nlm.nih.gov/pubmed/33083053
http://dx.doi.org/10.1155/2020/9873504
work_keys_str_mv AT ruxinyu correlationanalysisofrefractiveandvisualqualityafterwavefrontoptimizedlaserinsitukeratomileusisfor50and100anglekappacompensation
AT lizhengri correlationanalysisofrefractiveandvisualqualityafterwavefrontoptimizedlaserinsitukeratomileusisfor50and100anglekappacompensation
AT lichenglin correlationanalysisofrefractiveandvisualqualityafterwavefrontoptimizedlaserinsitukeratomileusisfor50and100anglekappacompensation
AT cuihong correlationanalysisofrefractiveandvisualqualityafterwavefrontoptimizedlaserinsitukeratomileusisfor50and100anglekappacompensation
AT dengwenqing correlationanalysisofrefractiveandvisualqualityafterwavefrontoptimizedlaserinsitukeratomileusisfor50and100anglekappacompensation
AT linshuhua correlationanalysisofrefractiveandvisualqualityafterwavefrontoptimizedlaserinsitukeratomileusisfor50and100anglekappacompensation
AT jiayujie correlationanalysisofrefractiveandvisualqualityafterwavefrontoptimizedlaserinsitukeratomileusisfor50and100anglekappacompensation
AT liyingjun correlationanalysisofrefractiveandvisualqualityafterwavefrontoptimizedlaserinsitukeratomileusisfor50and100anglekappacompensation