Iatrogenic Complete Ventilatory Failure in Two Neonates Undergoing Tracheoesophageal Fistula Repair
Tracheoesophageal fistula (TEF) is one of the most common congenital anomalies presenting for emergency surgical correction in a neonate. The surgical approach is through the right thoracotomy in the lateral decubitus position. The pathology and surgical approach complicate the ventilatory managemen...