Multiple Computed Tomography Robust Optimization to Account for Random Anatomic Density Variations During Intensity Modulated Proton Therapy

PURPOSE: To propose a method of optimizing intensity modulated proton therapy (IMPT) plans robust against dosimetric degradation caused by random anatomic variations during treatment. METHODS AND MATERIALS: Fifteen patients with prostate cancer treated with IMPT to the pelvic targets were nonrandoml...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhu, Mingyao, Kaiser, Adeel, Mishra, Mark V., Kwok, Young, Remick, Jill, DeCesaris, Cristina, Langen, Katja M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7557143/
https://www.ncbi.nlm.nih.gov/pubmed/33083665
http://dx.doi.org/10.1016/j.adro.2019.12.003
_version_ 1783594356046823424
author Zhu, Mingyao
Kaiser, Adeel
Mishra, Mark V.
Kwok, Young
Remick, Jill
DeCesaris, Cristina
Langen, Katja M.
author_facet Zhu, Mingyao
Kaiser, Adeel
Mishra, Mark V.
Kwok, Young
Remick, Jill
DeCesaris, Cristina
Langen, Katja M.
author_sort Zhu, Mingyao
collection PubMed
description PURPOSE: To propose a method of optimizing intensity modulated proton therapy (IMPT) plans robust against dosimetric degradation caused by random anatomic variations during treatment. METHODS AND MATERIALS: Fifteen patients with prostate cancer treated with IMPT to the pelvic targets were nonrandomly selected. On the repeated quality assurance computed tomography (QACTs) for some patients, bowel density changes were observed and caused dose degradation because the treated plans were not robustly optimized (non-RO). To mitigate this effect, we developed a robust planning method based on 3 CT images, including the native planning CT and its 2 copies, with the bowel structures being assigned to air and tissue, respectively. The RO settings included 5 mm setup uncertainty and 3.5% range uncertainty on 3 CTs. This method is called pseudomultiple-CT RO (pMCT-RO). Plans were also generated using RO on the native CT only, with the same setup and range uncertainties. This method is referred to as single-CT RO (SCT-RO). Doses on the QACTs and the nominal planning CT were compared for the 3 planning methods. RESULTS: All 3 plan methods provided sufficient clinical target volumes D95% and V95% on the QACTs. For pMCT-RO plans, the normal tissue D(max) on QACTs of all patients was at maximum 109.1%, compared with 144.4% and 116.9% for non-RO and SCT-RO plans, respectively. On the nominal plans, the rectum and bladder doses were similar among all 3 plans; however, the volume of normal tissue (excluding the rectum and bladder) receiving the prescription dose or higher is substantially reduced in either pMCT-RO plans or SCT-RO plans, compared with the non-RO plans. CONCLUSIONS: We developed a robust optimization method to further mitigate undesired dose heterogeneity caused by random anatomic changes in pelvic IMPT treatment. This method does not require additional patient CT scans. The pMCT-RO planning method has been implemented clinically since 2017 in our center.
format Online
Article
Text
id pubmed-7557143
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-75571432020-10-19 Multiple Computed Tomography Robust Optimization to Account for Random Anatomic Density Variations During Intensity Modulated Proton Therapy Zhu, Mingyao Kaiser, Adeel Mishra, Mark V. Kwok, Young Remick, Jill DeCesaris, Cristina Langen, Katja M. Adv Radiat Oncol Scientific Article PURPOSE: To propose a method of optimizing intensity modulated proton therapy (IMPT) plans robust against dosimetric degradation caused by random anatomic variations during treatment. METHODS AND MATERIALS: Fifteen patients with prostate cancer treated with IMPT to the pelvic targets were nonrandomly selected. On the repeated quality assurance computed tomography (QACTs) for some patients, bowel density changes were observed and caused dose degradation because the treated plans were not robustly optimized (non-RO). To mitigate this effect, we developed a robust planning method based on 3 CT images, including the native planning CT and its 2 copies, with the bowel structures being assigned to air and tissue, respectively. The RO settings included 5 mm setup uncertainty and 3.5% range uncertainty on 3 CTs. This method is called pseudomultiple-CT RO (pMCT-RO). Plans were also generated using RO on the native CT only, with the same setup and range uncertainties. This method is referred to as single-CT RO (SCT-RO). Doses on the QACTs and the nominal planning CT were compared for the 3 planning methods. RESULTS: All 3 plan methods provided sufficient clinical target volumes D95% and V95% on the QACTs. For pMCT-RO plans, the normal tissue D(max) on QACTs of all patients was at maximum 109.1%, compared with 144.4% and 116.9% for non-RO and SCT-RO plans, respectively. On the nominal plans, the rectum and bladder doses were similar among all 3 plans; however, the volume of normal tissue (excluding the rectum and bladder) receiving the prescription dose or higher is substantially reduced in either pMCT-RO plans or SCT-RO plans, compared with the non-RO plans. CONCLUSIONS: We developed a robust optimization method to further mitigate undesired dose heterogeneity caused by random anatomic changes in pelvic IMPT treatment. This method does not require additional patient CT scans. The pMCT-RO planning method has been implemented clinically since 2017 in our center. Elsevier 2019-12-26 /pmc/articles/PMC7557143/ /pubmed/33083665 http://dx.doi.org/10.1016/j.adro.2019.12.003 Text en © 2020 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Scientific Article
Zhu, Mingyao
Kaiser, Adeel
Mishra, Mark V.
Kwok, Young
Remick, Jill
DeCesaris, Cristina
Langen, Katja M.
Multiple Computed Tomography Robust Optimization to Account for Random Anatomic Density Variations During Intensity Modulated Proton Therapy
title Multiple Computed Tomography Robust Optimization to Account for Random Anatomic Density Variations During Intensity Modulated Proton Therapy
title_full Multiple Computed Tomography Robust Optimization to Account for Random Anatomic Density Variations During Intensity Modulated Proton Therapy
title_fullStr Multiple Computed Tomography Robust Optimization to Account for Random Anatomic Density Variations During Intensity Modulated Proton Therapy
title_full_unstemmed Multiple Computed Tomography Robust Optimization to Account for Random Anatomic Density Variations During Intensity Modulated Proton Therapy
title_short Multiple Computed Tomography Robust Optimization to Account for Random Anatomic Density Variations During Intensity Modulated Proton Therapy
title_sort multiple computed tomography robust optimization to account for random anatomic density variations during intensity modulated proton therapy
topic Scientific Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7557143/
https://www.ncbi.nlm.nih.gov/pubmed/33083665
http://dx.doi.org/10.1016/j.adro.2019.12.003
work_keys_str_mv AT zhumingyao multiplecomputedtomographyrobustoptimizationtoaccountforrandomanatomicdensityvariationsduringintensitymodulatedprotontherapy
AT kaiseradeel multiplecomputedtomographyrobustoptimizationtoaccountforrandomanatomicdensityvariationsduringintensitymodulatedprotontherapy
AT mishramarkv multiplecomputedtomographyrobustoptimizationtoaccountforrandomanatomicdensityvariationsduringintensitymodulatedprotontherapy
AT kwokyoung multiplecomputedtomographyrobustoptimizationtoaccountforrandomanatomicdensityvariationsduringintensitymodulatedprotontherapy
AT remickjill multiplecomputedtomographyrobustoptimizationtoaccountforrandomanatomicdensityvariationsduringintensitymodulatedprotontherapy
AT decesariscristina multiplecomputedtomographyrobustoptimizationtoaccountforrandomanatomicdensityvariationsduringintensitymodulatedprotontherapy
AT langenkatjam multiplecomputedtomographyrobustoptimizationtoaccountforrandomanatomicdensityvariationsduringintensitymodulatedprotontherapy