Cargando…

Optimization of Clarkson’s Method for Calculating Absorbed Dose under Compensator Filters used in Intensity-modulated Radiation Therapy

BACKGROUND: Intensity Modulated Radiation Therapy (IMRT) is extensively used in the treatment of malignancies. Clarkson’s method is one of the leading methods for dose calculation at open points present in irregular fields. OBJECTIVE: The aim of this study is to generalize the Clarkson’s method for...

Descripción completa

Detalles Bibliográficos
Autores principales: M., Pourkaveh, A., Haghparast, M. T., Eivazi, K., Ghazikhanlu Sani
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Shiraz University of Medical Sciences 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7557464/
https://www.ncbi.nlm.nih.gov/pubmed/33134216
http://dx.doi.org/10.31661/jbpe.v0i0.858
_version_ 1783594426629619712
author M., Pourkaveh
A., Haghparast
M. T., Eivazi
K., Ghazikhanlu Sani
author_facet M., Pourkaveh
A., Haghparast
M. T., Eivazi
K., Ghazikhanlu Sani
author_sort M., Pourkaveh
collection PubMed
description BACKGROUND: Intensity Modulated Radiation Therapy (IMRT) is extensively used in the treatment of malignancies. Clarkson’s method is one of the leading methods for dose calculation at open points present in irregular fields. OBJECTIVE: The aim of this study is to generalize the Clarkson’s method for dose calculation at points under compensator filters in IMRT method and its application in IMRT quality control as well. MATERIAL AND METHODS: In this experimental study, compensator filters were designed in two forms: flat filter and block piled-up compensator. The measurements for the compensator filters and open fields in 5 and10 cm depths at energy levels (6, 10 and 18 MV) and in fields with different dimensions were performed using “Mapcheck2” dosimeter. The aim of performing calculations is to derive the theoretical dose by the generalized Clarkson’s equation and comparing it with data resulted from the measurement for confirming the Clarkson’s equation presented. RESULTS: These results demonstrate the data derived from the generalized Clarkson’s method are in good agreement with the data resulted from measurement; the highest error of the proposed equation was 3% for flat filter, and less than 5% for block-piled-up filter. Higher error in the block-piled-up filter compared with the flat filter was due to the presence of leakage between these blocks. CONCLUSION: The results of this study demonstrated that the presented equation is reliable and valid, and the proposed equation can be applied for dose calculation at all points under the compensator filter or the shielded areas.
format Online
Article
Text
id pubmed-7557464
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Shiraz University of Medical Sciences
record_format MEDLINE/PubMed
spelling pubmed-75574642020-10-30 Optimization of Clarkson’s Method for Calculating Absorbed Dose under Compensator Filters used in Intensity-modulated Radiation Therapy M., Pourkaveh A., Haghparast M. T., Eivazi K., Ghazikhanlu Sani J Biomed Phys Eng Original Article BACKGROUND: Intensity Modulated Radiation Therapy (IMRT) is extensively used in the treatment of malignancies. Clarkson’s method is one of the leading methods for dose calculation at open points present in irregular fields. OBJECTIVE: The aim of this study is to generalize the Clarkson’s method for dose calculation at points under compensator filters in IMRT method and its application in IMRT quality control as well. MATERIAL AND METHODS: In this experimental study, compensator filters were designed in two forms: flat filter and block piled-up compensator. The measurements for the compensator filters and open fields in 5 and10 cm depths at energy levels (6, 10 and 18 MV) and in fields with different dimensions were performed using “Mapcheck2” dosimeter. The aim of performing calculations is to derive the theoretical dose by the generalized Clarkson’s equation and comparing it with data resulted from the measurement for confirming the Clarkson’s equation presented. RESULTS: These results demonstrate the data derived from the generalized Clarkson’s method are in good agreement with the data resulted from measurement; the highest error of the proposed equation was 3% for flat filter, and less than 5% for block-piled-up filter. Higher error in the block-piled-up filter compared with the flat filter was due to the presence of leakage between these blocks. CONCLUSION: The results of this study demonstrated that the presented equation is reliable and valid, and the proposed equation can be applied for dose calculation at all points under the compensator filter or the shielded areas. Shiraz University of Medical Sciences 2020-10-01 /pmc/articles/PMC7557464/ /pubmed/33134216 http://dx.doi.org/10.31661/jbpe.v0i0.858 Text en Copyright: © Journal of Biomedical Physics and Engineering http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 Unported License, ( http://creativecommons.org/licenses/by-nc/4.0/ ) which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
M., Pourkaveh
A., Haghparast
M. T., Eivazi
K., Ghazikhanlu Sani
Optimization of Clarkson’s Method for Calculating Absorbed Dose under Compensator Filters used in Intensity-modulated Radiation Therapy
title Optimization of Clarkson’s Method for Calculating Absorbed Dose under Compensator Filters used in Intensity-modulated Radiation Therapy
title_full Optimization of Clarkson’s Method for Calculating Absorbed Dose under Compensator Filters used in Intensity-modulated Radiation Therapy
title_fullStr Optimization of Clarkson’s Method for Calculating Absorbed Dose under Compensator Filters used in Intensity-modulated Radiation Therapy
title_full_unstemmed Optimization of Clarkson’s Method for Calculating Absorbed Dose under Compensator Filters used in Intensity-modulated Radiation Therapy
title_short Optimization of Clarkson’s Method for Calculating Absorbed Dose under Compensator Filters used in Intensity-modulated Radiation Therapy
title_sort optimization of clarkson’s method for calculating absorbed dose under compensator filters used in intensity-modulated radiation therapy
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7557464/
https://www.ncbi.nlm.nih.gov/pubmed/33134216
http://dx.doi.org/10.31661/jbpe.v0i0.858
work_keys_str_mv AT mpourkaveh optimizationofclarksonsmethodforcalculatingabsorbeddoseundercompensatorfiltersusedinintensitymodulatedradiationtherapy
AT ahaghparast optimizationofclarksonsmethodforcalculatingabsorbeddoseundercompensatorfiltersusedinintensitymodulatedradiationtherapy
AT mteivazi optimizationofclarksonsmethodforcalculatingabsorbeddoseundercompensatorfiltersusedinintensitymodulatedradiationtherapy
AT kghazikhanlusani optimizationofclarksonsmethodforcalculatingabsorbeddoseundercompensatorfiltersusedinintensitymodulatedradiationtherapy