Cargando…
Hearing-Impaired Listeners Show Reduced Attention to High-Frequency Information in the Presence of Low-Frequency Information
Many listeners with sensorineural hearing loss have uneven hearing sensitivity across frequencies. This study addressed whether this uneven hearing loss leads to a biasing of attention to different frequency regions. Normal-hearing (NH) and hearing-impaired (HI) listeners performed a pattern discrim...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7557677/ https://www.ncbi.nlm.nih.gov/pubmed/32853117 http://dx.doi.org/10.1177/2331216520945516 |
_version_ | 1783594469667373056 |
---|---|
author | Roverud, Elin Dubno, Judy R. Kidd, Gerald |
author_facet | Roverud, Elin Dubno, Judy R. Kidd, Gerald |
author_sort | Roverud, Elin |
collection | PubMed |
description | Many listeners with sensorineural hearing loss have uneven hearing sensitivity across frequencies. This study addressed whether this uneven hearing loss leads to a biasing of attention to different frequency regions. Normal-hearing (NH) and hearing-impaired (HI) listeners performed a pattern discrimination task at two distant center frequencies (CFs): 750 and 3500 Hz. The patterns were sequences of pure tones in which each successive tonal element was randomly selected from one of two possible frequencies surrounding a CF. The stimuli were presented at equal sensation levels to ensure equal audibility. In addition, the frequency separation of the tonal elements within a pattern was adjusted for each listener so that equal pattern discrimination performance was obtained for each CF in quiet. After these adjustments, the pattern discrimination task was performed under conditions in which independent patterns were presented at both CFs simultaneously. The listeners were instructed to attend to the low or high CF before the stimulus (assessing selective attention to frequency with instruction) or after the stimulus (divided attention, assessing inherent frequency biases). NH listeners demonstrated approximately equal performance decrements (re: quiet) between the two CFs. HI listeners demonstrated much larger performance decrements at the 3500 Hz CF than at the 750 Hz CF in combined-presentation conditions for both selective and divided attention conditions, indicating a low-frequency attentional bias that is apparently not under subject control. Surprisingly, the magnitude of this frequency bias was not related to the degree of asymmetry in thresholds at the two CFs. |
format | Online Article Text |
id | pubmed-7557677 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | SAGE Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-75576772020-10-26 Hearing-Impaired Listeners Show Reduced Attention to High-Frequency Information in the Presence of Low-Frequency Information Roverud, Elin Dubno, Judy R. Kidd, Gerald Trends Hear Original Article Many listeners with sensorineural hearing loss have uneven hearing sensitivity across frequencies. This study addressed whether this uneven hearing loss leads to a biasing of attention to different frequency regions. Normal-hearing (NH) and hearing-impaired (HI) listeners performed a pattern discrimination task at two distant center frequencies (CFs): 750 and 3500 Hz. The patterns were sequences of pure tones in which each successive tonal element was randomly selected from one of two possible frequencies surrounding a CF. The stimuli were presented at equal sensation levels to ensure equal audibility. In addition, the frequency separation of the tonal elements within a pattern was adjusted for each listener so that equal pattern discrimination performance was obtained for each CF in quiet. After these adjustments, the pattern discrimination task was performed under conditions in which independent patterns were presented at both CFs simultaneously. The listeners were instructed to attend to the low or high CF before the stimulus (assessing selective attention to frequency with instruction) or after the stimulus (divided attention, assessing inherent frequency biases). NH listeners demonstrated approximately equal performance decrements (re: quiet) between the two CFs. HI listeners demonstrated much larger performance decrements at the 3500 Hz CF than at the 750 Hz CF in combined-presentation conditions for both selective and divided attention conditions, indicating a low-frequency attentional bias that is apparently not under subject control. Surprisingly, the magnitude of this frequency bias was not related to the degree of asymmetry in thresholds at the two CFs. SAGE Publications 2020-08-27 /pmc/articles/PMC7557677/ /pubmed/32853117 http://dx.doi.org/10.1177/2331216520945516 Text en © The Author(s) 2020 https://creativecommons.org/licenses/by-nc/4.0/ Creative Commons Non Commercial CC BY-NC: This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage). |
spellingShingle | Original Article Roverud, Elin Dubno, Judy R. Kidd, Gerald Hearing-Impaired Listeners Show Reduced Attention to High-Frequency Information in the Presence of Low-Frequency Information |
title | Hearing-Impaired Listeners Show Reduced Attention to High-Frequency Information in the Presence of Low-Frequency Information |
title_full | Hearing-Impaired Listeners Show Reduced Attention to High-Frequency Information in the Presence of Low-Frequency Information |
title_fullStr | Hearing-Impaired Listeners Show Reduced Attention to High-Frequency Information in the Presence of Low-Frequency Information |
title_full_unstemmed | Hearing-Impaired Listeners Show Reduced Attention to High-Frequency Information in the Presence of Low-Frequency Information |
title_short | Hearing-Impaired Listeners Show Reduced Attention to High-Frequency Information in the Presence of Low-Frequency Information |
title_sort | hearing-impaired listeners show reduced attention to high-frequency information in the presence of low-frequency information |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7557677/ https://www.ncbi.nlm.nih.gov/pubmed/32853117 http://dx.doi.org/10.1177/2331216520945516 |
work_keys_str_mv | AT roverudelin hearingimpairedlistenersshowreducedattentiontohighfrequencyinformationinthepresenceoflowfrequencyinformation AT dubnojudyr hearingimpairedlistenersshowreducedattentiontohighfrequencyinformationinthepresenceoflowfrequencyinformation AT kiddgerald hearingimpairedlistenersshowreducedattentiontohighfrequencyinformationinthepresenceoflowfrequencyinformation |