The Accuracy of Electrical Cardiometry for the Noninvasive Determination of Cardiac Output before and after Lung Surgeries Compared to Transthoracic Echocardiography

BACKGROUND: The anatomical changes associated with lung surgeries may decrease cardiac output and heart function. Therefore, monitoring of cardiac output (CO) is of significant value in these patients for clinical decision-making. OBJECTIVE: This study is to evaluate the reliability of electrical ca...

Descripción completa

Detalles Bibliográficos
Autores principales: Elgebaly, Ahmed S., Anwar, Atteia G., Fathy, Sameh M., Sallam, Ayman, Elbarbary, Yaser
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7559959/
https://www.ncbi.nlm.nih.gov/pubmed/32687084
http://dx.doi.org/10.4103/aca.ACA_196_18
_version_ 1783594979911794688
author Elgebaly, Ahmed S.
Anwar, Atteia G.
Fathy, Sameh M.
Sallam, Ayman
Elbarbary, Yaser
author_facet Elgebaly, Ahmed S.
Anwar, Atteia G.
Fathy, Sameh M.
Sallam, Ayman
Elbarbary, Yaser
author_sort Elgebaly, Ahmed S.
collection PubMed
description BACKGROUND: The anatomical changes associated with lung surgeries may decrease cardiac output and heart function. Therefore, monitoring of cardiac output (CO) is of significant value in these patients for clinical decision-making. OBJECTIVE: This study is to evaluate the reliability of electrical cardiometry (EC) for the noninvasive continuous determination of CO after lobectomy or pneumonectomy compared to transthoracic echocardiography (TTE). PATIENTS AND METHODS: This study was carried out on 60 patients, age ≥18 years scheduled for elective lung surgery (lobectomy or pneumonectomy). All patients underwent simultaneous measurement by EC using the ICON_ device and by TTE by measuring left ventricle outflow tract diameter (LVOT) and velocity time integral (VTI). Heart rate (HR), systolic and diastolic blood pressure (SBP and DBP), stroke volume (SV), stroke volume index (SVI), CO, and cardiac index (CI) were measured 1 day before the surgery and 7 days after the surgery. RESULTS: There was no significant difference between TTE and EC regarding preoperative and postoperative HR, SV, SVI, CO, and CI. There was a strong positive correlation between TTE and EC as regard preoperative and postoperative HR, SV, SVI, CO, and CI. Bland and Altman analysis showed low bias with accepted limits of agreement of HR, SV, SVI, CO, and CI. Postoperative readings showed a significant increase in HR and a significant decrease in SV and CO (either by TTE or EC), SBP, and DBP as compared to preoperative reading. CONCLUSION: Compared to the TTE, EC provides accurate and reliable CO, SV, and HR measurements before and even after lung surgeries.
format Online
Article
Text
id pubmed-7559959
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-75599592020-10-20 The Accuracy of Electrical Cardiometry for the Noninvasive Determination of Cardiac Output before and after Lung Surgeries Compared to Transthoracic Echocardiography Elgebaly, Ahmed S. Anwar, Atteia G. Fathy, Sameh M. Sallam, Ayman Elbarbary, Yaser Ann Card Anaesth Original Article BACKGROUND: The anatomical changes associated with lung surgeries may decrease cardiac output and heart function. Therefore, monitoring of cardiac output (CO) is of significant value in these patients for clinical decision-making. OBJECTIVE: This study is to evaluate the reliability of electrical cardiometry (EC) for the noninvasive continuous determination of CO after lobectomy or pneumonectomy compared to transthoracic echocardiography (TTE). PATIENTS AND METHODS: This study was carried out on 60 patients, age ≥18 years scheduled for elective lung surgery (lobectomy or pneumonectomy). All patients underwent simultaneous measurement by EC using the ICON_ device and by TTE by measuring left ventricle outflow tract diameter (LVOT) and velocity time integral (VTI). Heart rate (HR), systolic and diastolic blood pressure (SBP and DBP), stroke volume (SV), stroke volume index (SVI), CO, and cardiac index (CI) were measured 1 day before the surgery and 7 days after the surgery. RESULTS: There was no significant difference between TTE and EC regarding preoperative and postoperative HR, SV, SVI, CO, and CI. There was a strong positive correlation between TTE and EC as regard preoperative and postoperative HR, SV, SVI, CO, and CI. Bland and Altman analysis showed low bias with accepted limits of agreement of HR, SV, SVI, CO, and CI. Postoperative readings showed a significant increase in HR and a significant decrease in SV and CO (either by TTE or EC), SBP, and DBP as compared to preoperative reading. CONCLUSION: Compared to the TTE, EC provides accurate and reliable CO, SV, and HR measurements before and even after lung surgeries. Wolters Kluwer - Medknow 2020 2020-07-17 /pmc/articles/PMC7559959/ /pubmed/32687084 http://dx.doi.org/10.4103/aca.ACA_196_18 Text en Copyright: © 2020 Annals of Cardiac Anaesthesia http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Elgebaly, Ahmed S.
Anwar, Atteia G.
Fathy, Sameh M.
Sallam, Ayman
Elbarbary, Yaser
The Accuracy of Electrical Cardiometry for the Noninvasive Determination of Cardiac Output before and after Lung Surgeries Compared to Transthoracic Echocardiography
title The Accuracy of Electrical Cardiometry for the Noninvasive Determination of Cardiac Output before and after Lung Surgeries Compared to Transthoracic Echocardiography
title_full The Accuracy of Electrical Cardiometry for the Noninvasive Determination of Cardiac Output before and after Lung Surgeries Compared to Transthoracic Echocardiography
title_fullStr The Accuracy of Electrical Cardiometry for the Noninvasive Determination of Cardiac Output before and after Lung Surgeries Compared to Transthoracic Echocardiography
title_full_unstemmed The Accuracy of Electrical Cardiometry for the Noninvasive Determination of Cardiac Output before and after Lung Surgeries Compared to Transthoracic Echocardiography
title_short The Accuracy of Electrical Cardiometry for the Noninvasive Determination of Cardiac Output before and after Lung Surgeries Compared to Transthoracic Echocardiography
title_sort accuracy of electrical cardiometry for the noninvasive determination of cardiac output before and after lung surgeries compared to transthoracic echocardiography
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7559959/
https://www.ncbi.nlm.nih.gov/pubmed/32687084
http://dx.doi.org/10.4103/aca.ACA_196_18
work_keys_str_mv AT elgebalyahmeds theaccuracyofelectricalcardiometryforthenoninvasivedeterminationofcardiacoutputbeforeandafterlungsurgeriescomparedtotransthoracicechocardiography
AT anwaratteiag theaccuracyofelectricalcardiometryforthenoninvasivedeterminationofcardiacoutputbeforeandafterlungsurgeriescomparedtotransthoracicechocardiography
AT fathysamehm theaccuracyofelectricalcardiometryforthenoninvasivedeterminationofcardiacoutputbeforeandafterlungsurgeriescomparedtotransthoracicechocardiography
AT sallamayman theaccuracyofelectricalcardiometryforthenoninvasivedeterminationofcardiacoutputbeforeandafterlungsurgeriescomparedtotransthoracicechocardiography
AT elbarbaryyaser theaccuracyofelectricalcardiometryforthenoninvasivedeterminationofcardiacoutputbeforeandafterlungsurgeriescomparedtotransthoracicechocardiography
AT elgebalyahmeds accuracyofelectricalcardiometryforthenoninvasivedeterminationofcardiacoutputbeforeandafterlungsurgeriescomparedtotransthoracicechocardiography
AT anwaratteiag accuracyofelectricalcardiometryforthenoninvasivedeterminationofcardiacoutputbeforeandafterlungsurgeriescomparedtotransthoracicechocardiography
AT fathysamehm accuracyofelectricalcardiometryforthenoninvasivedeterminationofcardiacoutputbeforeandafterlungsurgeriescomparedtotransthoracicechocardiography
AT sallamayman accuracyofelectricalcardiometryforthenoninvasivedeterminationofcardiacoutputbeforeandafterlungsurgeriescomparedtotransthoracicechocardiography
AT elbarbaryyaser accuracyofelectricalcardiometryforthenoninvasivedeterminationofcardiacoutputbeforeandafterlungsurgeriescomparedtotransthoracicechocardiography