Cargando…
Quantitative microbial risk assessment (QMRA) of occupational exposure to SARS-CoV-2 in wastewater treatment plants
The current global Severe Acute Respiratory Syndrome- Coronavirus-2 (SARS-CoV-2) epidemic has heightened calls for studies to evaluate respiratory exposure for wastewater treatment workers. In this global first study, we assess occupational health risks to wastewater treatment plant (WWTP) operators...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier B.V.
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7560119/ https://www.ncbi.nlm.nih.gov/pubmed/33498115 http://dx.doi.org/10.1016/j.scitotenv.2020.142989 |
_version_ | 1783595015704936448 |
---|---|
author | Dada, Ayokunle Christopher Gyawali, Pradip |
author_facet | Dada, Ayokunle Christopher Gyawali, Pradip |
author_sort | Dada, Ayokunle Christopher |
collection | PubMed |
description | The current global Severe Acute Respiratory Syndrome- Coronavirus-2 (SARS-CoV-2) epidemic has heightened calls for studies to evaluate respiratory exposure for wastewater treatment workers. In this global first study, we assess occupational health risks to wastewater treatment plant (WWTP) operators from inhalation of aerosolized SARS-CoV-2 using a Quantitative Microbiological Risk Assessment (QMRA) framework. The following considerations were used to develop the QMRA and assess the illness risks to workers: a) the proportion of the population who are infected and thus responsible for shedding SARS-CoV-2 into raw wastewater; b) the concentration of SARS-CoV-2 in raw and treated wastewater; c) the volume of aerosolized water inhaled by a WWTP operator during work; d) humidity and temperature-dependent viability of coronaviruses in aerosolized waste water; e) estimation of the amount, frequency, and duration of exposure; and f) exposure doses. The variables were then fed into an exponential dose response model to estimate the risks in three scenarios representing low-grade, moderate and aggressive outbreaks. These scenarios were designed on the assumption of 0.03%, 0.3% and 3% of the wastewater-generating population being infected with SARS-CoV-2. In terms of averaged-out illness risk profiles, the individual illness risks for low grade, moderate and aggressive outbreak scenarios respectively are 0.036, 0.32 and 3.21 illness cases per 1000 exposed WWTP operators. Our study suggests that the risk of accidental occupational exposure to SARS-CoV-2 in raw wastewater, via inhalation at the WWTP environment, is negligible, particularly when less than 0.3% of the population served by the plant are actively infected. |
format | Online Article Text |
id | pubmed-7560119 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Elsevier B.V. |
record_format | MEDLINE/PubMed |
spelling | pubmed-75601192020-10-16 Quantitative microbial risk assessment (QMRA) of occupational exposure to SARS-CoV-2 in wastewater treatment plants Dada, Ayokunle Christopher Gyawali, Pradip Sci Total Environ Short Communication The current global Severe Acute Respiratory Syndrome- Coronavirus-2 (SARS-CoV-2) epidemic has heightened calls for studies to evaluate respiratory exposure for wastewater treatment workers. In this global first study, we assess occupational health risks to wastewater treatment plant (WWTP) operators from inhalation of aerosolized SARS-CoV-2 using a Quantitative Microbiological Risk Assessment (QMRA) framework. The following considerations were used to develop the QMRA and assess the illness risks to workers: a) the proportion of the population who are infected and thus responsible for shedding SARS-CoV-2 into raw wastewater; b) the concentration of SARS-CoV-2 in raw and treated wastewater; c) the volume of aerosolized water inhaled by a WWTP operator during work; d) humidity and temperature-dependent viability of coronaviruses in aerosolized waste water; e) estimation of the amount, frequency, and duration of exposure; and f) exposure doses. The variables were then fed into an exponential dose response model to estimate the risks in three scenarios representing low-grade, moderate and aggressive outbreaks. These scenarios were designed on the assumption of 0.03%, 0.3% and 3% of the wastewater-generating population being infected with SARS-CoV-2. In terms of averaged-out illness risk profiles, the individual illness risks for low grade, moderate and aggressive outbreak scenarios respectively are 0.036, 0.32 and 3.21 illness cases per 1000 exposed WWTP operators. Our study suggests that the risk of accidental occupational exposure to SARS-CoV-2 in raw wastewater, via inhalation at the WWTP environment, is negligible, particularly when less than 0.3% of the population served by the plant are actively infected. Elsevier B.V. 2021-04-01 2020-10-15 /pmc/articles/PMC7560119/ /pubmed/33498115 http://dx.doi.org/10.1016/j.scitotenv.2020.142989 Text en © 2020 Elsevier B.V. All rights reserved. Since January 2020 Elsevier has created a COVID-19 resource centre with free information in English and Mandarin on the novel coronavirus COVID-19. The COVID-19 resource centre is hosted on Elsevier Connect, the company's public news and information website. Elsevier hereby grants permission to make all its COVID-19-related research that is available on the COVID-19 resource centre - including this research content - immediately available in PubMed Central and other publicly funded repositories, such as the WHO COVID database with rights for unrestricted research re-use and analyses in any form or by any means with acknowledgement of the original source. These permissions are granted for free by Elsevier for as long as the COVID-19 resource centre remains active. |
spellingShingle | Short Communication Dada, Ayokunle Christopher Gyawali, Pradip Quantitative microbial risk assessment (QMRA) of occupational exposure to SARS-CoV-2 in wastewater treatment plants |
title | Quantitative microbial risk assessment (QMRA) of occupational exposure to SARS-CoV-2 in wastewater treatment plants |
title_full | Quantitative microbial risk assessment (QMRA) of occupational exposure to SARS-CoV-2 in wastewater treatment plants |
title_fullStr | Quantitative microbial risk assessment (QMRA) of occupational exposure to SARS-CoV-2 in wastewater treatment plants |
title_full_unstemmed | Quantitative microbial risk assessment (QMRA) of occupational exposure to SARS-CoV-2 in wastewater treatment plants |
title_short | Quantitative microbial risk assessment (QMRA) of occupational exposure to SARS-CoV-2 in wastewater treatment plants |
title_sort | quantitative microbial risk assessment (qmra) of occupational exposure to sars-cov-2 in wastewater treatment plants |
topic | Short Communication |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7560119/ https://www.ncbi.nlm.nih.gov/pubmed/33498115 http://dx.doi.org/10.1016/j.scitotenv.2020.142989 |
work_keys_str_mv | AT dadaayokunlechristopher quantitativemicrobialriskassessmentqmraofoccupationalexposuretosarscov2inwastewatertreatmentplants AT gyawalipradip quantitativemicrobialriskassessmentqmraofoccupationalexposuretosarscov2inwastewatertreatmentplants |