Cargando…
Healing comparison of porcine cutaneous incisions made with cold steel scalpel, standard electrosurgical blade, and a novel tissue dissector
BACKGROUND: Standard electrosurgery provides superior hemostasis compared to a cold steel scalpel, but inferior tissue healing. A novel electrosurgical blade with an advanced waveform, the MEGADYNE ACE BLADE™ 700 Soft Tissue Dissector (ACE), was designed to provide both excellent hemostasis and woun...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7561048/ https://www.ncbi.nlm.nih.gov/pubmed/33073169 http://dx.doi.org/10.15761/MRI.1000124 |
_version_ | 1783595188779745280 |
---|---|
author | Wu, Albert Y Baldwin, Thomas J Patel, Bhupendra C Clymer, Jeffrey W Lewis, Ryan D |
author_facet | Wu, Albert Y Baldwin, Thomas J Patel, Bhupendra C Clymer, Jeffrey W Lewis, Ryan D |
author_sort | Wu, Albert Y |
collection | PubMed |
description | BACKGROUND: Standard electrosurgery provides superior hemostasis compared to a cold steel scalpel, but inferior tissue healing. A novel electrosurgical blade with an advanced waveform, the MEGADYNE ACE BLADE™ 700 Soft Tissue Dissector (ACE), was designed to provide both excellent hemostasis and wound healing. This study compared ACE to scalpel and standard electrosurgery in a porcine model of wound healing. METHODS: Skin incisions from six pigs were evaluated at time points of 0, 1, 2, 3 and 6 weeks after application of the three devices. Histopathology was performed on samples from each time point. For each non-initial time point, the healing incisions were photographed for later evaluation by expert graders, and excised for wound strength testing. RESULTS: Time 0 photomicrographs showed a gradient of thermal tissue damage by initial incision, ranging from no damage made by the scalpel, minimal damage made by ACE, and twice the ACE damage made by a nonstick PTFE-coated electrosurgical blade. Histopathologic analysis at 6 weeks showed comparable dermal scar width measurements for scalpel and ACE incisions. Scars were wider for incisions made by standard electrosurgical blade. Wound strength was greater for scalpel and ACE than for standard electrosurgery. Cosmetic results at 6 weeks were not significantly different between scalpel and ACE incisions, while standard electrosurgical blade incisions were significantly inferior to ACE (odds ratio: 53.4, p<0.001). CONCLUSION: The MEGADYNE ACE BLADE™ 700 Soft Tissue Dissector represents a significant improvement in electrosurgical technology for skin incisions and dispels the traditional concerns of delayed healing and poor cosmetic result that have been attributed to using conventional electrosurgical blades for skin incisions. |
format | Online Article Text |
id | pubmed-7561048 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
record_format | MEDLINE/PubMed |
spelling | pubmed-75610482020-10-15 Healing comparison of porcine cutaneous incisions made with cold steel scalpel, standard electrosurgical blade, and a novel tissue dissector Wu, Albert Y Baldwin, Thomas J Patel, Bhupendra C Clymer, Jeffrey W Lewis, Ryan D Med Res Innov Article BACKGROUND: Standard electrosurgery provides superior hemostasis compared to a cold steel scalpel, but inferior tissue healing. A novel electrosurgical blade with an advanced waveform, the MEGADYNE ACE BLADE™ 700 Soft Tissue Dissector (ACE), was designed to provide both excellent hemostasis and wound healing. This study compared ACE to scalpel and standard electrosurgery in a porcine model of wound healing. METHODS: Skin incisions from six pigs were evaluated at time points of 0, 1, 2, 3 and 6 weeks after application of the three devices. Histopathology was performed on samples from each time point. For each non-initial time point, the healing incisions were photographed for later evaluation by expert graders, and excised for wound strength testing. RESULTS: Time 0 photomicrographs showed a gradient of thermal tissue damage by initial incision, ranging from no damage made by the scalpel, minimal damage made by ACE, and twice the ACE damage made by a nonstick PTFE-coated electrosurgical blade. Histopathologic analysis at 6 weeks showed comparable dermal scar width measurements for scalpel and ACE incisions. Scars were wider for incisions made by standard electrosurgical blade. Wound strength was greater for scalpel and ACE than for standard electrosurgery. Cosmetic results at 6 weeks were not significantly different between scalpel and ACE incisions, while standard electrosurgical blade incisions were significantly inferior to ACE (odds ratio: 53.4, p<0.001). CONCLUSION: The MEGADYNE ACE BLADE™ 700 Soft Tissue Dissector represents a significant improvement in electrosurgical technology for skin incisions and dispels the traditional concerns of delayed healing and poor cosmetic result that have been attributed to using conventional electrosurgical blades for skin incisions. 2017-10-27 2017-10 /pmc/articles/PMC7561048/ /pubmed/33073169 http://dx.doi.org/10.15761/MRI.1000124 Text en This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. http://creativecommons.org/licenses/by/4.0/ |
spellingShingle | Article Wu, Albert Y Baldwin, Thomas J Patel, Bhupendra C Clymer, Jeffrey W Lewis, Ryan D Healing comparison of porcine cutaneous incisions made with cold steel scalpel, standard electrosurgical blade, and a novel tissue dissector |
title | Healing comparison of porcine cutaneous incisions made with cold steel scalpel, standard electrosurgical blade, and a novel tissue dissector |
title_full | Healing comparison of porcine cutaneous incisions made with cold steel scalpel, standard electrosurgical blade, and a novel tissue dissector |
title_fullStr | Healing comparison of porcine cutaneous incisions made with cold steel scalpel, standard electrosurgical blade, and a novel tissue dissector |
title_full_unstemmed | Healing comparison of porcine cutaneous incisions made with cold steel scalpel, standard electrosurgical blade, and a novel tissue dissector |
title_short | Healing comparison of porcine cutaneous incisions made with cold steel scalpel, standard electrosurgical blade, and a novel tissue dissector |
title_sort | healing comparison of porcine cutaneous incisions made with cold steel scalpel, standard electrosurgical blade, and a novel tissue dissector |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7561048/ https://www.ncbi.nlm.nih.gov/pubmed/33073169 http://dx.doi.org/10.15761/MRI.1000124 |
work_keys_str_mv | AT wualberty healingcomparisonofporcinecutaneousincisionsmadewithcoldsteelscalpelstandardelectrosurgicalbladeandanoveltissuedissector AT baldwinthomasj healingcomparisonofporcinecutaneousincisionsmadewithcoldsteelscalpelstandardelectrosurgicalbladeandanoveltissuedissector AT patelbhupendrac healingcomparisonofporcinecutaneousincisionsmadewithcoldsteelscalpelstandardelectrosurgicalbladeandanoveltissuedissector AT clymerjeffreyw healingcomparisonofporcinecutaneousincisionsmadewithcoldsteelscalpelstandardelectrosurgicalbladeandanoveltissuedissector AT lewisryand healingcomparisonofporcinecutaneousincisionsmadewithcoldsteelscalpelstandardelectrosurgicalbladeandanoveltissuedissector |