Cargando…

Quality Characteristics and Clinical Relevance of In-House 3D-Printed Customized Polyetheretherketone (PEEK) Implants for Craniofacial Reconstruction

Additive manufacturing (AM) of patient-specific implants (PSIs) is gradually moving towards in-house or point-of-care (POC) manufacturing. Polyetheretherketone (PEEK) has been used in cranioplasty cases as a reliable alternative to other alloplastic materials. As only a few fused filament fabricatio...

Descripción completa

Detalles Bibliográficos
Autores principales: Sharma, Neha, Aghlmandi, Soheila, Cao, Shuaishuai, Kunz, Christoph, Honigmann, Philipp, Thieringer, Florian M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7563642/
https://www.ncbi.nlm.nih.gov/pubmed/32878160
http://dx.doi.org/10.3390/jcm9092818
_version_ 1783595535127543808
author Sharma, Neha
Aghlmandi, Soheila
Cao, Shuaishuai
Kunz, Christoph
Honigmann, Philipp
Thieringer, Florian M.
author_facet Sharma, Neha
Aghlmandi, Soheila
Cao, Shuaishuai
Kunz, Christoph
Honigmann, Philipp
Thieringer, Florian M.
author_sort Sharma, Neha
collection PubMed
description Additive manufacturing (AM) of patient-specific implants (PSIs) is gradually moving towards in-house or point-of-care (POC) manufacturing. Polyetheretherketone (PEEK) has been used in cranioplasty cases as a reliable alternative to other alloplastic materials. As only a few fused filament fabrication (FFF) printers are suitable for in-house manufacturing, the quality characteristics of the implants fabricated by FFF technology are still under investigated. This paper aimed to investigate PEEK PSIs fabricated in-house for craniofacial reconstruction, discussing the key challenges during the FFF printing process. Two exemplary cases of class III (Group 1) and class IV (Group 2) craniofacial defects were selected for the fabrication of PEEK PSIs. Taguchi’s L9 orthogonal array was selected for the following nonthermal printing process parameters, i.e., layer thickness, infill rate, number of shells, and infill pattern, and an assessment of the dimensional accuracy of the fabricated implants was made. The root mean square (RMS) values revealed higher deviations in Group 1 PSIs (0.790 mm) compared to Group 2 PSIs (0.241 mm). Horizontal lines, or the characteristic FFF stair-stepping effect, were more perceptible across the surface of Group 1 PSIs. Although Group 2 PSIs revealed no discoloration, Group 1 PSIs displayed different zones of crystallinity. These results suggest that the dimensional accuracy of PSIs were within the clinically acceptable range; however, attention must be paid towards a requirement of optimum thermal management during the printing process to fabricate implants of uniform crystallinity.
format Online
Article
Text
id pubmed-7563642
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-75636422020-10-27 Quality Characteristics and Clinical Relevance of In-House 3D-Printed Customized Polyetheretherketone (PEEK) Implants for Craniofacial Reconstruction Sharma, Neha Aghlmandi, Soheila Cao, Shuaishuai Kunz, Christoph Honigmann, Philipp Thieringer, Florian M. J Clin Med Article Additive manufacturing (AM) of patient-specific implants (PSIs) is gradually moving towards in-house or point-of-care (POC) manufacturing. Polyetheretherketone (PEEK) has been used in cranioplasty cases as a reliable alternative to other alloplastic materials. As only a few fused filament fabrication (FFF) printers are suitable for in-house manufacturing, the quality characteristics of the implants fabricated by FFF technology are still under investigated. This paper aimed to investigate PEEK PSIs fabricated in-house for craniofacial reconstruction, discussing the key challenges during the FFF printing process. Two exemplary cases of class III (Group 1) and class IV (Group 2) craniofacial defects were selected for the fabrication of PEEK PSIs. Taguchi’s L9 orthogonal array was selected for the following nonthermal printing process parameters, i.e., layer thickness, infill rate, number of shells, and infill pattern, and an assessment of the dimensional accuracy of the fabricated implants was made. The root mean square (RMS) values revealed higher deviations in Group 1 PSIs (0.790 mm) compared to Group 2 PSIs (0.241 mm). Horizontal lines, or the characteristic FFF stair-stepping effect, were more perceptible across the surface of Group 1 PSIs. Although Group 2 PSIs revealed no discoloration, Group 1 PSIs displayed different zones of crystallinity. These results suggest that the dimensional accuracy of PSIs were within the clinically acceptable range; however, attention must be paid towards a requirement of optimum thermal management during the printing process to fabricate implants of uniform crystallinity. MDPI 2020-08-31 /pmc/articles/PMC7563642/ /pubmed/32878160 http://dx.doi.org/10.3390/jcm9092818 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Sharma, Neha
Aghlmandi, Soheila
Cao, Shuaishuai
Kunz, Christoph
Honigmann, Philipp
Thieringer, Florian M.
Quality Characteristics and Clinical Relevance of In-House 3D-Printed Customized Polyetheretherketone (PEEK) Implants for Craniofacial Reconstruction
title Quality Characteristics and Clinical Relevance of In-House 3D-Printed Customized Polyetheretherketone (PEEK) Implants for Craniofacial Reconstruction
title_full Quality Characteristics and Clinical Relevance of In-House 3D-Printed Customized Polyetheretherketone (PEEK) Implants for Craniofacial Reconstruction
title_fullStr Quality Characteristics and Clinical Relevance of In-House 3D-Printed Customized Polyetheretherketone (PEEK) Implants for Craniofacial Reconstruction
title_full_unstemmed Quality Characteristics and Clinical Relevance of In-House 3D-Printed Customized Polyetheretherketone (PEEK) Implants for Craniofacial Reconstruction
title_short Quality Characteristics and Clinical Relevance of In-House 3D-Printed Customized Polyetheretherketone (PEEK) Implants for Craniofacial Reconstruction
title_sort quality characteristics and clinical relevance of in-house 3d-printed customized polyetheretherketone (peek) implants for craniofacial reconstruction
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7563642/
https://www.ncbi.nlm.nih.gov/pubmed/32878160
http://dx.doi.org/10.3390/jcm9092818
work_keys_str_mv AT sharmaneha qualitycharacteristicsandclinicalrelevanceofinhouse3dprintedcustomizedpolyetheretherketonepeekimplantsforcraniofacialreconstruction
AT aghlmandisoheila qualitycharacteristicsandclinicalrelevanceofinhouse3dprintedcustomizedpolyetheretherketonepeekimplantsforcraniofacialreconstruction
AT caoshuaishuai qualitycharacteristicsandclinicalrelevanceofinhouse3dprintedcustomizedpolyetheretherketonepeekimplantsforcraniofacialreconstruction
AT kunzchristoph qualitycharacteristicsandclinicalrelevanceofinhouse3dprintedcustomizedpolyetheretherketonepeekimplantsforcraniofacialreconstruction
AT honigmannphilipp qualitycharacteristicsandclinicalrelevanceofinhouse3dprintedcustomizedpolyetheretherketonepeekimplantsforcraniofacialreconstruction
AT thieringerflorianm qualitycharacteristicsandclinicalrelevanceofinhouse3dprintedcustomizedpolyetheretherketonepeekimplantsforcraniofacialreconstruction