Cargando…
Quality Characteristics and Clinical Relevance of In-House 3D-Printed Customized Polyetheretherketone (PEEK) Implants for Craniofacial Reconstruction
Additive manufacturing (AM) of patient-specific implants (PSIs) is gradually moving towards in-house or point-of-care (POC) manufacturing. Polyetheretherketone (PEEK) has been used in cranioplasty cases as a reliable alternative to other alloplastic materials. As only a few fused filament fabricatio...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7563642/ https://www.ncbi.nlm.nih.gov/pubmed/32878160 http://dx.doi.org/10.3390/jcm9092818 |
_version_ | 1783595535127543808 |
---|---|
author | Sharma, Neha Aghlmandi, Soheila Cao, Shuaishuai Kunz, Christoph Honigmann, Philipp Thieringer, Florian M. |
author_facet | Sharma, Neha Aghlmandi, Soheila Cao, Shuaishuai Kunz, Christoph Honigmann, Philipp Thieringer, Florian M. |
author_sort | Sharma, Neha |
collection | PubMed |
description | Additive manufacturing (AM) of patient-specific implants (PSIs) is gradually moving towards in-house or point-of-care (POC) manufacturing. Polyetheretherketone (PEEK) has been used in cranioplasty cases as a reliable alternative to other alloplastic materials. As only a few fused filament fabrication (FFF) printers are suitable for in-house manufacturing, the quality characteristics of the implants fabricated by FFF technology are still under investigated. This paper aimed to investigate PEEK PSIs fabricated in-house for craniofacial reconstruction, discussing the key challenges during the FFF printing process. Two exemplary cases of class III (Group 1) and class IV (Group 2) craniofacial defects were selected for the fabrication of PEEK PSIs. Taguchi’s L9 orthogonal array was selected for the following nonthermal printing process parameters, i.e., layer thickness, infill rate, number of shells, and infill pattern, and an assessment of the dimensional accuracy of the fabricated implants was made. The root mean square (RMS) values revealed higher deviations in Group 1 PSIs (0.790 mm) compared to Group 2 PSIs (0.241 mm). Horizontal lines, or the characteristic FFF stair-stepping effect, were more perceptible across the surface of Group 1 PSIs. Although Group 2 PSIs revealed no discoloration, Group 1 PSIs displayed different zones of crystallinity. These results suggest that the dimensional accuracy of PSIs were within the clinically acceptable range; however, attention must be paid towards a requirement of optimum thermal management during the printing process to fabricate implants of uniform crystallinity. |
format | Online Article Text |
id | pubmed-7563642 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-75636422020-10-27 Quality Characteristics and Clinical Relevance of In-House 3D-Printed Customized Polyetheretherketone (PEEK) Implants for Craniofacial Reconstruction Sharma, Neha Aghlmandi, Soheila Cao, Shuaishuai Kunz, Christoph Honigmann, Philipp Thieringer, Florian M. J Clin Med Article Additive manufacturing (AM) of patient-specific implants (PSIs) is gradually moving towards in-house or point-of-care (POC) manufacturing. Polyetheretherketone (PEEK) has been used in cranioplasty cases as a reliable alternative to other alloplastic materials. As only a few fused filament fabrication (FFF) printers are suitable for in-house manufacturing, the quality characteristics of the implants fabricated by FFF technology are still under investigated. This paper aimed to investigate PEEK PSIs fabricated in-house for craniofacial reconstruction, discussing the key challenges during the FFF printing process. Two exemplary cases of class III (Group 1) and class IV (Group 2) craniofacial defects were selected for the fabrication of PEEK PSIs. Taguchi’s L9 orthogonal array was selected for the following nonthermal printing process parameters, i.e., layer thickness, infill rate, number of shells, and infill pattern, and an assessment of the dimensional accuracy of the fabricated implants was made. The root mean square (RMS) values revealed higher deviations in Group 1 PSIs (0.790 mm) compared to Group 2 PSIs (0.241 mm). Horizontal lines, or the characteristic FFF stair-stepping effect, were more perceptible across the surface of Group 1 PSIs. Although Group 2 PSIs revealed no discoloration, Group 1 PSIs displayed different zones of crystallinity. These results suggest that the dimensional accuracy of PSIs were within the clinically acceptable range; however, attention must be paid towards a requirement of optimum thermal management during the printing process to fabricate implants of uniform crystallinity. MDPI 2020-08-31 /pmc/articles/PMC7563642/ /pubmed/32878160 http://dx.doi.org/10.3390/jcm9092818 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Sharma, Neha Aghlmandi, Soheila Cao, Shuaishuai Kunz, Christoph Honigmann, Philipp Thieringer, Florian M. Quality Characteristics and Clinical Relevance of In-House 3D-Printed Customized Polyetheretherketone (PEEK) Implants for Craniofacial Reconstruction |
title | Quality Characteristics and Clinical Relevance of In-House 3D-Printed Customized Polyetheretherketone (PEEK) Implants for Craniofacial Reconstruction |
title_full | Quality Characteristics and Clinical Relevance of In-House 3D-Printed Customized Polyetheretherketone (PEEK) Implants for Craniofacial Reconstruction |
title_fullStr | Quality Characteristics and Clinical Relevance of In-House 3D-Printed Customized Polyetheretherketone (PEEK) Implants for Craniofacial Reconstruction |
title_full_unstemmed | Quality Characteristics and Clinical Relevance of In-House 3D-Printed Customized Polyetheretherketone (PEEK) Implants for Craniofacial Reconstruction |
title_short | Quality Characteristics and Clinical Relevance of In-House 3D-Printed Customized Polyetheretherketone (PEEK) Implants for Craniofacial Reconstruction |
title_sort | quality characteristics and clinical relevance of in-house 3d-printed customized polyetheretherketone (peek) implants for craniofacial reconstruction |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7563642/ https://www.ncbi.nlm.nih.gov/pubmed/32878160 http://dx.doi.org/10.3390/jcm9092818 |
work_keys_str_mv | AT sharmaneha qualitycharacteristicsandclinicalrelevanceofinhouse3dprintedcustomizedpolyetheretherketonepeekimplantsforcraniofacialreconstruction AT aghlmandisoheila qualitycharacteristicsandclinicalrelevanceofinhouse3dprintedcustomizedpolyetheretherketonepeekimplantsforcraniofacialreconstruction AT caoshuaishuai qualitycharacteristicsandclinicalrelevanceofinhouse3dprintedcustomizedpolyetheretherketonepeekimplantsforcraniofacialreconstruction AT kunzchristoph qualitycharacteristicsandclinicalrelevanceofinhouse3dprintedcustomizedpolyetheretherketonepeekimplantsforcraniofacialreconstruction AT honigmannphilipp qualitycharacteristicsandclinicalrelevanceofinhouse3dprintedcustomizedpolyetheretherketonepeekimplantsforcraniofacialreconstruction AT thieringerflorianm qualitycharacteristicsandclinicalrelevanceofinhouse3dprintedcustomizedpolyetheretherketonepeekimplantsforcraniofacialreconstruction |