Cargando…

Evaluation of the Reliability, Reproducibility and Validity of Digital Orthodontic Measurements Based on Various Digital Models among Young Patients

The advantages of intraoral model scanning have yielded recent developments. However, few studies have explored the orthodontic clinical use of this technique particularly among young patients. This study aimed to evaluate the reliability, reproducibility and validity of the orthodontic measurements...

Descripción completa

Detalles Bibliográficos
Autores principales: Park, Seo-Hyun, Byun, Soo-Hwan, Oh, So-Hee, Lee, Hye-Lim, Kim, Ju-Won, Yang, Byoung-Eun, Park, In-Young
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7564383/
https://www.ncbi.nlm.nih.gov/pubmed/32846984
http://dx.doi.org/10.3390/jcm9092728
_version_ 1783595701719007232
author Park, Seo-Hyun
Byun, Soo-Hwan
Oh, So-Hee
Lee, Hye-Lim
Kim, Ju-Won
Yang, Byoung-Eun
Park, In-Young
author_facet Park, Seo-Hyun
Byun, Soo-Hwan
Oh, So-Hee
Lee, Hye-Lim
Kim, Ju-Won
Yang, Byoung-Eun
Park, In-Young
author_sort Park, Seo-Hyun
collection PubMed
description The advantages of intraoral model scanning have yielded recent developments. However, few studies have explored the orthodontic clinical use of this technique particularly among young patients. This study aimed to evaluate the reliability, reproducibility and validity of the orthodontic measurements: tooth width, arch length and arch length discrepancy in each digital model obtained by model scanner and intraoral scanner, relative to a plaster model. Arch length measured using two methods: curved arch length (CAL) measured automatically by digital program and sum of sectional liner arch length (SLAL) measured sum of anterior and posterior liner arch lengths. Arch length discrepancy calculated each arch length measurement methods: curved arch length discrepancy (CALD) and sum of sectional liner arch length discrepancy (SLALD). Forty young patients were eligible for the study. A plaster model (P), model-scanned digital model (MSD) and intraoral scanned digital model (ISD) were acquired from each patient. The reliability of the measurements was evaluated using Pearson’s correlation coefficient, while the reproducibility was evaluated using the intraclass correlation coefficient. The validity was assessed by a paired t-test. All measurements measured in P, MSD and ISD exhibited good reliability and reproducibility. Most orthodontic measurements despite of CAL in MSD exhibited high validity. Only the SLAL and SLALD in ISD group differed significantly, despite the good validity of the tooth width, CAL and CALD. The measurements based on the digital program appeared high reliability, reproducibility and accurate than conventional measurement. However, SLAL and SLALD in ISD group appeared shorter because of distortion during intraoral scanning. However, this could be compensated by using digital programed curved arch. Although the validity of SLAL and SLALD in the ISD group differed statistically, the difference is not considered clinically significant. Although MSD and ISD are acceptable for a clinical space analysis, clinicians should be aware of digital model-induced errors.
format Online
Article
Text
id pubmed-7564383
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-75643832020-10-26 Evaluation of the Reliability, Reproducibility and Validity of Digital Orthodontic Measurements Based on Various Digital Models among Young Patients Park, Seo-Hyun Byun, Soo-Hwan Oh, So-Hee Lee, Hye-Lim Kim, Ju-Won Yang, Byoung-Eun Park, In-Young J Clin Med Article The advantages of intraoral model scanning have yielded recent developments. However, few studies have explored the orthodontic clinical use of this technique particularly among young patients. This study aimed to evaluate the reliability, reproducibility and validity of the orthodontic measurements: tooth width, arch length and arch length discrepancy in each digital model obtained by model scanner and intraoral scanner, relative to a plaster model. Arch length measured using two methods: curved arch length (CAL) measured automatically by digital program and sum of sectional liner arch length (SLAL) measured sum of anterior and posterior liner arch lengths. Arch length discrepancy calculated each arch length measurement methods: curved arch length discrepancy (CALD) and sum of sectional liner arch length discrepancy (SLALD). Forty young patients were eligible for the study. A plaster model (P), model-scanned digital model (MSD) and intraoral scanned digital model (ISD) were acquired from each patient. The reliability of the measurements was evaluated using Pearson’s correlation coefficient, while the reproducibility was evaluated using the intraclass correlation coefficient. The validity was assessed by a paired t-test. All measurements measured in P, MSD and ISD exhibited good reliability and reproducibility. Most orthodontic measurements despite of CAL in MSD exhibited high validity. Only the SLAL and SLALD in ISD group differed significantly, despite the good validity of the tooth width, CAL and CALD. The measurements based on the digital program appeared high reliability, reproducibility and accurate than conventional measurement. However, SLAL and SLALD in ISD group appeared shorter because of distortion during intraoral scanning. However, this could be compensated by using digital programed curved arch. Although the validity of SLAL and SLALD in the ISD group differed statistically, the difference is not considered clinically significant. Although MSD and ISD are acceptable for a clinical space analysis, clinicians should be aware of digital model-induced errors. MDPI 2020-08-24 /pmc/articles/PMC7564383/ /pubmed/32846984 http://dx.doi.org/10.3390/jcm9092728 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Park, Seo-Hyun
Byun, Soo-Hwan
Oh, So-Hee
Lee, Hye-Lim
Kim, Ju-Won
Yang, Byoung-Eun
Park, In-Young
Evaluation of the Reliability, Reproducibility and Validity of Digital Orthodontic Measurements Based on Various Digital Models among Young Patients
title Evaluation of the Reliability, Reproducibility and Validity of Digital Orthodontic Measurements Based on Various Digital Models among Young Patients
title_full Evaluation of the Reliability, Reproducibility and Validity of Digital Orthodontic Measurements Based on Various Digital Models among Young Patients
title_fullStr Evaluation of the Reliability, Reproducibility and Validity of Digital Orthodontic Measurements Based on Various Digital Models among Young Patients
title_full_unstemmed Evaluation of the Reliability, Reproducibility and Validity of Digital Orthodontic Measurements Based on Various Digital Models among Young Patients
title_short Evaluation of the Reliability, Reproducibility and Validity of Digital Orthodontic Measurements Based on Various Digital Models among Young Patients
title_sort evaluation of the reliability, reproducibility and validity of digital orthodontic measurements based on various digital models among young patients
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7564383/
https://www.ncbi.nlm.nih.gov/pubmed/32846984
http://dx.doi.org/10.3390/jcm9092728
work_keys_str_mv AT parkseohyun evaluationofthereliabilityreproducibilityandvalidityofdigitalorthodonticmeasurementsbasedonvariousdigitalmodelsamongyoungpatients
AT byunsoohwan evaluationofthereliabilityreproducibilityandvalidityofdigitalorthodonticmeasurementsbasedonvariousdigitalmodelsamongyoungpatients
AT ohsohee evaluationofthereliabilityreproducibilityandvalidityofdigitalorthodonticmeasurementsbasedonvariousdigitalmodelsamongyoungpatients
AT leehyelim evaluationofthereliabilityreproducibilityandvalidityofdigitalorthodonticmeasurementsbasedonvariousdigitalmodelsamongyoungpatients
AT kimjuwon evaluationofthereliabilityreproducibilityandvalidityofdigitalorthodonticmeasurementsbasedonvariousdigitalmodelsamongyoungpatients
AT yangbyoungeun evaluationofthereliabilityreproducibilityandvalidityofdigitalorthodonticmeasurementsbasedonvariousdigitalmodelsamongyoungpatients
AT parkinyoung evaluationofthereliabilityreproducibilityandvalidityofdigitalorthodonticmeasurementsbasedonvariousdigitalmodelsamongyoungpatients