Cargando…

Evaluation of the Accero Stent for Stent-Assisted Coiling of Unruptured Wide-Necked Intracranial Aneurysm Treatment with Short-Term Follow-Up

Background: Stent-assisted coiling is an effective method of treating intracranial aneurysms. The aim of the study was to assess the safety and efficacy of the new Accero stent for the treatment of intracranial aneurysms. Materials and Methods: It was a retrospective, single-center study. Eighteen u...

Descripción completa

Detalles Bibliográficos
Autores principales: Poncyljusz, Wojciech, Kubiak, Kinga, Sagan, Leszek, Limanówka, Bartosz, Kołaczyk, Katarzyna
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7564441/
https://www.ncbi.nlm.nih.gov/pubmed/32877984
http://dx.doi.org/10.3390/jcm9092808
_version_ 1783595715591667712
author Poncyljusz, Wojciech
Kubiak, Kinga
Sagan, Leszek
Limanówka, Bartosz
Kołaczyk, Katarzyna
author_facet Poncyljusz, Wojciech
Kubiak, Kinga
Sagan, Leszek
Limanówka, Bartosz
Kołaczyk, Katarzyna
author_sort Poncyljusz, Wojciech
collection PubMed
description Background: Stent-assisted coiling is an effective method of treating intracranial aneurysms. The aim of the study was to assess the safety and efficacy of the new Accero stent for the treatment of intracranial aneurysms. Materials and Methods: It was a retrospective, single-center study. Eighteen unruptured intracranial aneurysms were treated using the stent-assisted coiling method with the Accero stent. Patient demographics, aneurysm characteristics, procedural parameters, grade of occlusion, complications, and clinical results were analyzed. Follow-up magnetic resonance (MR) was performed 6 months after intervention. Results: Seventeen patients with 18 incidental unruptured aneurysms were electively treated with coiling and the Accero stent. The aneurysms were located on internal carotid artery (ICA), middle cerebral artery (MCA) and basilar artery (BA). All stents were deployed successfully. Immediate complete occlusion rate Raymond-Roy occlusion classification (RROC) class I was achieved in 13 cases and class II in 4 cases. Complications occurred in 2/17 treatments and included guidewire stent perforation with subarachnoid hemorrhage (SAH) and stent deformation. Vascular spasm in the subarachnoid hemorrhage (SAH) patient subsided before discharge. Ninety days after intervention, the modified Rankin Scale (mRS) value was 0. RROC class I was observed in 88.23% of cases in follow-up. Conclusion: The Accero stent provides excellent support for coil mass. It constitutes an efficacious device with good initial occlusion rate for treating wide-necked unruptured intracranial aneurysms.
format Online
Article
Text
id pubmed-7564441
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-75644412020-10-26 Evaluation of the Accero Stent for Stent-Assisted Coiling of Unruptured Wide-Necked Intracranial Aneurysm Treatment with Short-Term Follow-Up Poncyljusz, Wojciech Kubiak, Kinga Sagan, Leszek Limanówka, Bartosz Kołaczyk, Katarzyna J Clin Med Article Background: Stent-assisted coiling is an effective method of treating intracranial aneurysms. The aim of the study was to assess the safety and efficacy of the new Accero stent for the treatment of intracranial aneurysms. Materials and Methods: It was a retrospective, single-center study. Eighteen unruptured intracranial aneurysms were treated using the stent-assisted coiling method with the Accero stent. Patient demographics, aneurysm characteristics, procedural parameters, grade of occlusion, complications, and clinical results were analyzed. Follow-up magnetic resonance (MR) was performed 6 months after intervention. Results: Seventeen patients with 18 incidental unruptured aneurysms were electively treated with coiling and the Accero stent. The aneurysms were located on internal carotid artery (ICA), middle cerebral artery (MCA) and basilar artery (BA). All stents were deployed successfully. Immediate complete occlusion rate Raymond-Roy occlusion classification (RROC) class I was achieved in 13 cases and class II in 4 cases. Complications occurred in 2/17 treatments and included guidewire stent perforation with subarachnoid hemorrhage (SAH) and stent deformation. Vascular spasm in the subarachnoid hemorrhage (SAH) patient subsided before discharge. Ninety days after intervention, the modified Rankin Scale (mRS) value was 0. RROC class I was observed in 88.23% of cases in follow-up. Conclusion: The Accero stent provides excellent support for coil mass. It constitutes an efficacious device with good initial occlusion rate for treating wide-necked unruptured intracranial aneurysms. MDPI 2020-08-31 /pmc/articles/PMC7564441/ /pubmed/32877984 http://dx.doi.org/10.3390/jcm9092808 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Poncyljusz, Wojciech
Kubiak, Kinga
Sagan, Leszek
Limanówka, Bartosz
Kołaczyk, Katarzyna
Evaluation of the Accero Stent for Stent-Assisted Coiling of Unruptured Wide-Necked Intracranial Aneurysm Treatment with Short-Term Follow-Up
title Evaluation of the Accero Stent for Stent-Assisted Coiling of Unruptured Wide-Necked Intracranial Aneurysm Treatment with Short-Term Follow-Up
title_full Evaluation of the Accero Stent for Stent-Assisted Coiling of Unruptured Wide-Necked Intracranial Aneurysm Treatment with Short-Term Follow-Up
title_fullStr Evaluation of the Accero Stent for Stent-Assisted Coiling of Unruptured Wide-Necked Intracranial Aneurysm Treatment with Short-Term Follow-Up
title_full_unstemmed Evaluation of the Accero Stent for Stent-Assisted Coiling of Unruptured Wide-Necked Intracranial Aneurysm Treatment with Short-Term Follow-Up
title_short Evaluation of the Accero Stent for Stent-Assisted Coiling of Unruptured Wide-Necked Intracranial Aneurysm Treatment with Short-Term Follow-Up
title_sort evaluation of the accero stent for stent-assisted coiling of unruptured wide-necked intracranial aneurysm treatment with short-term follow-up
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7564441/
https://www.ncbi.nlm.nih.gov/pubmed/32877984
http://dx.doi.org/10.3390/jcm9092808
work_keys_str_mv AT poncyljuszwojciech evaluationoftheaccerostentforstentassistedcoilingofunrupturedwideneckedintracranialaneurysmtreatmentwithshorttermfollowup
AT kubiakkinga evaluationoftheaccerostentforstentassistedcoilingofunrupturedwideneckedintracranialaneurysmtreatmentwithshorttermfollowup
AT saganleszek evaluationoftheaccerostentforstentassistedcoilingofunrupturedwideneckedintracranialaneurysmtreatmentwithshorttermfollowup
AT limanowkabartosz evaluationoftheaccerostentforstentassistedcoilingofunrupturedwideneckedintracranialaneurysmtreatmentwithshorttermfollowup
AT kołaczykkatarzyna evaluationoftheaccerostentforstentassistedcoilingofunrupturedwideneckedintracranialaneurysmtreatmentwithshorttermfollowup