Cargando…
Bilateral implantation of +56 and +58 diopter custom-made intraocular lenses in patient with extreme nanophthalmos
PURPOSE: To present the case of a 60-year-old patient with severe nanophthalmic eyes, who underwent cataract surgery with a bilateral implantation of custom-made high-power intraocular lenses (IOLs). OBSERVATIONS: The axial length was 14.94 and 15.05 mm of the right and the left eye, respectively. T...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7566091/ https://www.ncbi.nlm.nih.gov/pubmed/33089013 http://dx.doi.org/10.1016/j.ajoc.2020.100963 |
_version_ | 1783596075691540480 |
---|---|
author | Naujokaitis, Tadas Scharf, Debora Baur, Isabella Khoramnia, Ramin Auffarth, Gerd U. |
author_facet | Naujokaitis, Tadas Scharf, Debora Baur, Isabella Khoramnia, Ramin Auffarth, Gerd U. |
author_sort | Naujokaitis, Tadas |
collection | PubMed |
description | PURPOSE: To present the case of a 60-year-old patient with severe nanophthalmic eyes, who underwent cataract surgery with a bilateral implantation of custom-made high-power intraocular lenses (IOLs). OBSERVATIONS: The axial length was 14.94 and 15.05 mm of the right and the left eye, respectively. The preoperative corrected distance visual acuity (CDVA) was +0.46 logMAR (20/63) in the right eye and +0.58 logMAR (20/80) in the left eye with rigid contact lenses of +17.5 D bilaterally. The calculated IOL power for emmetropia with different formulas ranged from +55.28 to +70.09 D. The IOL power selection was based on the average value from four formulas (Haigis, Holladay 1, Holladay 2, SRK/T) with the target refraction of emmetropia. Custom-made +56.0 and + 58.0 D Aspira-aAY IOLs (HumanOptics AG, Erlangen, Germany) were implanted without any complications. The postoperative CDVA was +0.40 logMAR (20/50) and +0.60 logMAR (20/80). The manifest refraction spherical equivalents were +0.625 D and −0.375 D. CONCLUSIONS AND IMPORTANCE: Even in eyes with the axial length of only 15 mm, cataract surgery can be successfully performed after adequate preparation. High-power customized IOLs allow complete correction of hyperopia but caution is required with the results from different IOL power calculation formulas, which can be misleading. |
format | Online Article Text |
id | pubmed-7566091 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-75660912020-10-20 Bilateral implantation of +56 and +58 diopter custom-made intraocular lenses in patient with extreme nanophthalmos Naujokaitis, Tadas Scharf, Debora Baur, Isabella Khoramnia, Ramin Auffarth, Gerd U. Am J Ophthalmol Case Rep Case Report PURPOSE: To present the case of a 60-year-old patient with severe nanophthalmic eyes, who underwent cataract surgery with a bilateral implantation of custom-made high-power intraocular lenses (IOLs). OBSERVATIONS: The axial length was 14.94 and 15.05 mm of the right and the left eye, respectively. The preoperative corrected distance visual acuity (CDVA) was +0.46 logMAR (20/63) in the right eye and +0.58 logMAR (20/80) in the left eye with rigid contact lenses of +17.5 D bilaterally. The calculated IOL power for emmetropia with different formulas ranged from +55.28 to +70.09 D. The IOL power selection was based on the average value from four formulas (Haigis, Holladay 1, Holladay 2, SRK/T) with the target refraction of emmetropia. Custom-made +56.0 and + 58.0 D Aspira-aAY IOLs (HumanOptics AG, Erlangen, Germany) were implanted without any complications. The postoperative CDVA was +0.40 logMAR (20/50) and +0.60 logMAR (20/80). The manifest refraction spherical equivalents were +0.625 D and −0.375 D. CONCLUSIONS AND IMPORTANCE: Even in eyes with the axial length of only 15 mm, cataract surgery can be successfully performed after adequate preparation. High-power customized IOLs allow complete correction of hyperopia but caution is required with the results from different IOL power calculation formulas, which can be misleading. Elsevier 2020-10-09 /pmc/articles/PMC7566091/ /pubmed/33089013 http://dx.doi.org/10.1016/j.ajoc.2020.100963 Text en © 2020 Published by Elsevier Inc. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Case Report Naujokaitis, Tadas Scharf, Debora Baur, Isabella Khoramnia, Ramin Auffarth, Gerd U. Bilateral implantation of +56 and +58 diopter custom-made intraocular lenses in patient with extreme nanophthalmos |
title | Bilateral implantation of +56 and +58 diopter custom-made intraocular lenses in patient with extreme nanophthalmos |
title_full | Bilateral implantation of +56 and +58 diopter custom-made intraocular lenses in patient with extreme nanophthalmos |
title_fullStr | Bilateral implantation of +56 and +58 diopter custom-made intraocular lenses in patient with extreme nanophthalmos |
title_full_unstemmed | Bilateral implantation of +56 and +58 diopter custom-made intraocular lenses in patient with extreme nanophthalmos |
title_short | Bilateral implantation of +56 and +58 diopter custom-made intraocular lenses in patient with extreme nanophthalmos |
title_sort | bilateral implantation of +56 and +58 diopter custom-made intraocular lenses in patient with extreme nanophthalmos |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7566091/ https://www.ncbi.nlm.nih.gov/pubmed/33089013 http://dx.doi.org/10.1016/j.ajoc.2020.100963 |
work_keys_str_mv | AT naujokaitistadas bilateralimplantationof56and58dioptercustommadeintraocularlensesinpatientwithextremenanophthalmos AT scharfdebora bilateralimplantationof56and58dioptercustommadeintraocularlensesinpatientwithextremenanophthalmos AT baurisabella bilateralimplantationof56and58dioptercustommadeintraocularlensesinpatientwithextremenanophthalmos AT khoramniaramin bilateralimplantationof56and58dioptercustommadeintraocularlensesinpatientwithextremenanophthalmos AT auffarthgerdu bilateralimplantationof56and58dioptercustommadeintraocularlensesinpatientwithextremenanophthalmos |