Cargando…

Bilateral implantation of +56 and +58 diopter custom-made intraocular lenses in patient with extreme nanophthalmos

PURPOSE: To present the case of a 60-year-old patient with severe nanophthalmic eyes, who underwent cataract surgery with a bilateral implantation of custom-made high-power intraocular lenses (IOLs). OBSERVATIONS: The axial length was 14.94 and 15.05 mm of the right and the left eye, respectively. T...

Descripción completa

Detalles Bibliográficos
Autores principales: Naujokaitis, Tadas, Scharf, Debora, Baur, Isabella, Khoramnia, Ramin, Auffarth, Gerd U.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7566091/
https://www.ncbi.nlm.nih.gov/pubmed/33089013
http://dx.doi.org/10.1016/j.ajoc.2020.100963
_version_ 1783596075691540480
author Naujokaitis, Tadas
Scharf, Debora
Baur, Isabella
Khoramnia, Ramin
Auffarth, Gerd U.
author_facet Naujokaitis, Tadas
Scharf, Debora
Baur, Isabella
Khoramnia, Ramin
Auffarth, Gerd U.
author_sort Naujokaitis, Tadas
collection PubMed
description PURPOSE: To present the case of a 60-year-old patient with severe nanophthalmic eyes, who underwent cataract surgery with a bilateral implantation of custom-made high-power intraocular lenses (IOLs). OBSERVATIONS: The axial length was 14.94 and 15.05 mm of the right and the left eye, respectively. The preoperative corrected distance visual acuity (CDVA) was +0.46 logMAR (20/63) in the right eye and +0.58 logMAR (20/80) in the left eye with rigid contact lenses of +17.5 D bilaterally. The calculated IOL power for emmetropia with different formulas ranged from +55.28 to +70.09 D. The IOL power selection was based on the average value from four formulas (Haigis, Holladay 1, Holladay 2, SRK/T) with the target refraction of emmetropia. Custom-made +56.0 and + 58.0 D Aspira-aAY IOLs (HumanOptics AG, Erlangen, Germany) were implanted without any complications. The postoperative CDVA was +0.40 logMAR (20/50) and +0.60 logMAR (20/80). The manifest refraction spherical equivalents were +0.625 D and −0.375 D. CONCLUSIONS AND IMPORTANCE: Even in eyes with the axial length of only 15 mm, cataract surgery can be successfully performed after adequate preparation. High-power customized IOLs allow complete correction of hyperopia but caution is required with the results from different IOL power calculation formulas, which can be misleading.
format Online
Article
Text
id pubmed-7566091
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-75660912020-10-20 Bilateral implantation of +56 and +58 diopter custom-made intraocular lenses in patient with extreme nanophthalmos Naujokaitis, Tadas Scharf, Debora Baur, Isabella Khoramnia, Ramin Auffarth, Gerd U. Am J Ophthalmol Case Rep Case Report PURPOSE: To present the case of a 60-year-old patient with severe nanophthalmic eyes, who underwent cataract surgery with a bilateral implantation of custom-made high-power intraocular lenses (IOLs). OBSERVATIONS: The axial length was 14.94 and 15.05 mm of the right and the left eye, respectively. The preoperative corrected distance visual acuity (CDVA) was +0.46 logMAR (20/63) in the right eye and +0.58 logMAR (20/80) in the left eye with rigid contact lenses of +17.5 D bilaterally. The calculated IOL power for emmetropia with different formulas ranged from +55.28 to +70.09 D. The IOL power selection was based on the average value from four formulas (Haigis, Holladay 1, Holladay 2, SRK/T) with the target refraction of emmetropia. Custom-made +56.0 and + 58.0 D Aspira-aAY IOLs (HumanOptics AG, Erlangen, Germany) were implanted without any complications. The postoperative CDVA was +0.40 logMAR (20/50) and +0.60 logMAR (20/80). The manifest refraction spherical equivalents were +0.625 D and −0.375 D. CONCLUSIONS AND IMPORTANCE: Even in eyes with the axial length of only 15 mm, cataract surgery can be successfully performed after adequate preparation. High-power customized IOLs allow complete correction of hyperopia but caution is required with the results from different IOL power calculation formulas, which can be misleading. Elsevier 2020-10-09 /pmc/articles/PMC7566091/ /pubmed/33089013 http://dx.doi.org/10.1016/j.ajoc.2020.100963 Text en © 2020 Published by Elsevier Inc. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Case Report
Naujokaitis, Tadas
Scharf, Debora
Baur, Isabella
Khoramnia, Ramin
Auffarth, Gerd U.
Bilateral implantation of +56 and +58 diopter custom-made intraocular lenses in patient with extreme nanophthalmos
title Bilateral implantation of +56 and +58 diopter custom-made intraocular lenses in patient with extreme nanophthalmos
title_full Bilateral implantation of +56 and +58 diopter custom-made intraocular lenses in patient with extreme nanophthalmos
title_fullStr Bilateral implantation of +56 and +58 diopter custom-made intraocular lenses in patient with extreme nanophthalmos
title_full_unstemmed Bilateral implantation of +56 and +58 diopter custom-made intraocular lenses in patient with extreme nanophthalmos
title_short Bilateral implantation of +56 and +58 diopter custom-made intraocular lenses in patient with extreme nanophthalmos
title_sort bilateral implantation of +56 and +58 diopter custom-made intraocular lenses in patient with extreme nanophthalmos
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7566091/
https://www.ncbi.nlm.nih.gov/pubmed/33089013
http://dx.doi.org/10.1016/j.ajoc.2020.100963
work_keys_str_mv AT naujokaitistadas bilateralimplantationof56and58dioptercustommadeintraocularlensesinpatientwithextremenanophthalmos
AT scharfdebora bilateralimplantationof56and58dioptercustommadeintraocularlensesinpatientwithextremenanophthalmos
AT baurisabella bilateralimplantationof56and58dioptercustommadeintraocularlensesinpatientwithextremenanophthalmos
AT khoramniaramin bilateralimplantationof56and58dioptercustommadeintraocularlensesinpatientwithextremenanophthalmos
AT auffarthgerdu bilateralimplantationof56and58dioptercustommadeintraocularlensesinpatientwithextremenanophthalmos