AIM: This study aims to assess the diagnostic accuracy of new custom-made pulse oximeter sensor holder in assessment of actual pulp status with three pulp sensibility tests. MATERIALS AND METHODS: Seventy-nine single canal teeth requiring endodontic therapy was included in the study. The tooth that...

Descripción completa

Detalles Bibliográficos
Autores principales: Janani, Krishnamachari, Ajitha, P, Sandhya, Raghu, Subbaiyan, Haripriya, Jose, Jerry
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7567235/
https://www.ncbi.nlm.nih.gov/pubmed/33102292
http://dx.doi.org/10.4103/jfmpc.jfmpc_73_20
_version_ 1783596284079243264
author Janani, Krishnamachari
Ajitha, P
Sandhya, Raghu
Subbaiyan, Haripriya
Jose, Jerry
author_facet Janani, Krishnamachari
Ajitha, P
Sandhya, Raghu
Subbaiyan, Haripriya
Jose, Jerry
author_sort Janani, Krishnamachari
collection PubMed
description AIM: This study aims to assess the diagnostic accuracy of new custom-made pulse oximeter sensor holder in assessment of actual pulp status with three pulp sensibility tests. MATERIALS AND METHODS: Seventy-nine single canal teeth requiring endodontic therapy was included in the study. The tooth that was requiring root canal treatment was tested with heat test, cold test, electric pulp test, and pulse oximeter. Between each test, a time period of 2 min was allowed. The response from three pulp sensibility tests and the reading from pulse oximeter were recorded. Following which root canal treatment was performed. The result obtained from four pulp tests were correlated with the clinical finding after access cavity preparation. The data obtained was statistically assessed. Receiver operator characteristic (ROC) curve analysis was performed to assess the efficacy of the pulp tests. In the above statistical tools, the probability value. 05 is considered as significant level. RESULTS: The overall diagnostic accuracy was found to be significantly higher with pulse oximeter when compared with other three pulp sensibility tests. The ROC curve demonstrates the results obtained from pulse oximeter was found to be more reliable than other pulp tests. CONCLUSION: Within the limitation of the study, diagnostic accuracy of pulse oximeter with custom made sensor holder was reliable and accurate in assessment of actual pulp status.
format Online
Article
Text
id pubmed-7567235
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-75672352020-10-22 Efficiency of new custom-made pulse oximeter sensor holder in assessment of actual pulp status Janani, Krishnamachari Ajitha, P Sandhya, Raghu Subbaiyan, Haripriya Jose, Jerry J Family Med Prim Care Original Article AIM: This study aims to assess the diagnostic accuracy of new custom-made pulse oximeter sensor holder in assessment of actual pulp status with three pulp sensibility tests. MATERIALS AND METHODS: Seventy-nine single canal teeth requiring endodontic therapy was included in the study. The tooth that was requiring root canal treatment was tested with heat test, cold test, electric pulp test, and pulse oximeter. Between each test, a time period of 2 min was allowed. The response from three pulp sensibility tests and the reading from pulse oximeter were recorded. Following which root canal treatment was performed. The result obtained from four pulp tests were correlated with the clinical finding after access cavity preparation. The data obtained was statistically assessed. Receiver operator characteristic (ROC) curve analysis was performed to assess the efficacy of the pulp tests. In the above statistical tools, the probability value. 05 is considered as significant level. RESULTS: The overall diagnostic accuracy was found to be significantly higher with pulse oximeter when compared with other three pulp sensibility tests. The ROC curve demonstrates the results obtained from pulse oximeter was found to be more reliable than other pulp tests. CONCLUSION: Within the limitation of the study, diagnostic accuracy of pulse oximeter with custom made sensor holder was reliable and accurate in assessment of actual pulp status. Wolters Kluwer - Medknow 2020-07-30 /pmc/articles/PMC7567235/ /pubmed/33102292 http://dx.doi.org/10.4103/jfmpc.jfmpc_73_20 Text en Copyright: © 2020 Journal of Family Medicine and Primary Care http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Janani, Krishnamachari
Ajitha, P
Sandhya, Raghu
Subbaiyan, Haripriya
Jose, Jerry
Efficiency of new custom-made pulse oximeter sensor holder in assessment of actual pulp status
title Efficiency of new custom-made pulse oximeter sensor holder in assessment of actual pulp status
title_full Efficiency of new custom-made pulse oximeter sensor holder in assessment of actual pulp status
title_fullStr Efficiency of new custom-made pulse oximeter sensor holder in assessment of actual pulp status
title_full_unstemmed Efficiency of new custom-made pulse oximeter sensor holder in assessment of actual pulp status
title_short Efficiency of new custom-made pulse oximeter sensor holder in assessment of actual pulp status
title_sort efficiency of new custom-made pulse oximeter sensor holder in assessment of actual pulp status
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7567235/
https://www.ncbi.nlm.nih.gov/pubmed/33102292
http://dx.doi.org/10.4103/jfmpc.jfmpc_73_20
work_keys_str_mv AT jananikrishnamachari efficiencyofnewcustommadepulseoximetersensorholderinassessmentofactualpulpstatus
AT ajithap efficiencyofnewcustommadepulseoximetersensorholderinassessmentofactualpulpstatus
AT sandhyaraghu efficiencyofnewcustommadepulseoximetersensorholderinassessmentofactualpulpstatus
AT subbaiyanharipriya efficiencyofnewcustommadepulseoximetersensorholderinassessmentofactualpulpstatus
AT josejerry efficiencyofnewcustommadepulseoximetersensorholderinassessmentofactualpulpstatus