Cargando…

Technique for single-step lymphocyte isolation from an endoscopic biopsy specimen for the diagnosis of gastrointestinal lymphoma

In this paper, we introduce a simplified, one-step procedure for lymphocyte isolation from an endoscopically biopsied fragment. For lymphocyte isolation, an endoscopically harvested specimen and 5 mL of normal saline solution were placed in a wire mesh strainer set in a porcelain bowl. To obtain the...

Descripción completa

Detalles Bibliográficos
Autores principales: Iwamuro, Masaya, Takahashi, Takahide, Watanabe, Natsuki, Omote, Sizuma, Matsueda, Katsunori, Tanaka, Takehiro, Ennishi, Daisuke, Otsuka, Fumio, Yoshino, Tadashi, Okada, Hiroyuki
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7569335/
https://www.ncbi.nlm.nih.gov/pubmed/33102158
http://dx.doi.org/10.1016/j.mex.2020.101095
_version_ 1783596709501206528
author Iwamuro, Masaya
Takahashi, Takahide
Watanabe, Natsuki
Omote, Sizuma
Matsueda, Katsunori
Tanaka, Takehiro
Ennishi, Daisuke
Otsuka, Fumio
Yoshino, Tadashi
Okada, Hiroyuki
author_facet Iwamuro, Masaya
Takahashi, Takahide
Watanabe, Natsuki
Omote, Sizuma
Matsueda, Katsunori
Tanaka, Takehiro
Ennishi, Daisuke
Otsuka, Fumio
Yoshino, Tadashi
Okada, Hiroyuki
author_sort Iwamuro, Masaya
collection PubMed
description In this paper, we introduce a simplified, one-step procedure for lymphocyte isolation from an endoscopically biopsied fragment. For lymphocyte isolation, an endoscopically harvested specimen and 5 mL of normal saline solution were placed in a wire mesh strainer set in a porcelain bowl. To obtain the lymphocyte suspension, the solid specimen was crushed using the rubber portion of a plunger of a 10 mL injection syringe. Flow cytometry was performed using the lymphocyte suspension. For validating our methods, the one-step lymphocyte isolation technique was used to perform flow cytometry on samples from 23 patients with (n = 12) or without (n = 11) gastrointestinal lymphoma. Flow cytometry of light chain expression was performed in all patient samples (feasibility: 100%). Sensitivity was 83.3% (10/12) and specificity was 100% (11/11). In conclusion, lymphocytes isolated from a single endoscopic biopsy specimen using our simplified and quick procedure are suitable for flow cytometry. Considering that flow cytometry has an important advantage of providing the results on the examination day itself, the results of this study suggest that flow cytometric analysis using our single-step lymphocyte isolation technique can be potentially used to diagnose lymphoma in the gastrointestinal mucosa. • We introduce a simplified, one-step procedure for lymphocyte isolation from an endoscopically biopsied fragment. • Our technique is feasible for flow cytometric analysis in patients with gastrointestinal lymphoma as well as those with gastrointestinal lesions that are suspected to be lymphoma.
format Online
Article
Text
id pubmed-7569335
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-75693352020-10-22 Technique for single-step lymphocyte isolation from an endoscopic biopsy specimen for the diagnosis of gastrointestinal lymphoma Iwamuro, Masaya Takahashi, Takahide Watanabe, Natsuki Omote, Sizuma Matsueda, Katsunori Tanaka, Takehiro Ennishi, Daisuke Otsuka, Fumio Yoshino, Tadashi Okada, Hiroyuki MethodsX Method Article In this paper, we introduce a simplified, one-step procedure for lymphocyte isolation from an endoscopically biopsied fragment. For lymphocyte isolation, an endoscopically harvested specimen and 5 mL of normal saline solution were placed in a wire mesh strainer set in a porcelain bowl. To obtain the lymphocyte suspension, the solid specimen was crushed using the rubber portion of a plunger of a 10 mL injection syringe. Flow cytometry was performed using the lymphocyte suspension. For validating our methods, the one-step lymphocyte isolation technique was used to perform flow cytometry on samples from 23 patients with (n = 12) or without (n = 11) gastrointestinal lymphoma. Flow cytometry of light chain expression was performed in all patient samples (feasibility: 100%). Sensitivity was 83.3% (10/12) and specificity was 100% (11/11). In conclusion, lymphocytes isolated from a single endoscopic biopsy specimen using our simplified and quick procedure are suitable for flow cytometry. Considering that flow cytometry has an important advantage of providing the results on the examination day itself, the results of this study suggest that flow cytometric analysis using our single-step lymphocyte isolation technique can be potentially used to diagnose lymphoma in the gastrointestinal mucosa. • We introduce a simplified, one-step procedure for lymphocyte isolation from an endoscopically biopsied fragment. • Our technique is feasible for flow cytometric analysis in patients with gastrointestinal lymphoma as well as those with gastrointestinal lesions that are suspected to be lymphoma. Elsevier 2020-10-10 /pmc/articles/PMC7569335/ /pubmed/33102158 http://dx.doi.org/10.1016/j.mex.2020.101095 Text en © 2020 The Author(s). Published by Elsevier B.V. http://creativecommons.org/licenses/by/4.0/ This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Method Article
Iwamuro, Masaya
Takahashi, Takahide
Watanabe, Natsuki
Omote, Sizuma
Matsueda, Katsunori
Tanaka, Takehiro
Ennishi, Daisuke
Otsuka, Fumio
Yoshino, Tadashi
Okada, Hiroyuki
Technique for single-step lymphocyte isolation from an endoscopic biopsy specimen for the diagnosis of gastrointestinal lymphoma
title Technique for single-step lymphocyte isolation from an endoscopic biopsy specimen for the diagnosis of gastrointestinal lymphoma
title_full Technique for single-step lymphocyte isolation from an endoscopic biopsy specimen for the diagnosis of gastrointestinal lymphoma
title_fullStr Technique for single-step lymphocyte isolation from an endoscopic biopsy specimen for the diagnosis of gastrointestinal lymphoma
title_full_unstemmed Technique for single-step lymphocyte isolation from an endoscopic biopsy specimen for the diagnosis of gastrointestinal lymphoma
title_short Technique for single-step lymphocyte isolation from an endoscopic biopsy specimen for the diagnosis of gastrointestinal lymphoma
title_sort technique for single-step lymphocyte isolation from an endoscopic biopsy specimen for the diagnosis of gastrointestinal lymphoma
topic Method Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7569335/
https://www.ncbi.nlm.nih.gov/pubmed/33102158
http://dx.doi.org/10.1016/j.mex.2020.101095
work_keys_str_mv AT iwamuromasaya techniqueforsinglesteplymphocyteisolationfromanendoscopicbiopsyspecimenforthediagnosisofgastrointestinallymphoma
AT takahashitakahide techniqueforsinglesteplymphocyteisolationfromanendoscopicbiopsyspecimenforthediagnosisofgastrointestinallymphoma
AT watanabenatsuki techniqueforsinglesteplymphocyteisolationfromanendoscopicbiopsyspecimenforthediagnosisofgastrointestinallymphoma
AT omotesizuma techniqueforsinglesteplymphocyteisolationfromanendoscopicbiopsyspecimenforthediagnosisofgastrointestinallymphoma
AT matsuedakatsunori techniqueforsinglesteplymphocyteisolationfromanendoscopicbiopsyspecimenforthediagnosisofgastrointestinallymphoma
AT tanakatakehiro techniqueforsinglesteplymphocyteisolationfromanendoscopicbiopsyspecimenforthediagnosisofgastrointestinallymphoma
AT ennishidaisuke techniqueforsinglesteplymphocyteisolationfromanendoscopicbiopsyspecimenforthediagnosisofgastrointestinallymphoma
AT otsukafumio techniqueforsinglesteplymphocyteisolationfromanendoscopicbiopsyspecimenforthediagnosisofgastrointestinallymphoma
AT yoshinotadashi techniqueforsinglesteplymphocyteisolationfromanendoscopicbiopsyspecimenforthediagnosisofgastrointestinallymphoma
AT okadahiroyuki techniqueforsinglesteplymphocyteisolationfromanendoscopicbiopsyspecimenforthediagnosisofgastrointestinallymphoma