Cargando…

Electrochemical Detection of Pyocyanin as a Biomarker for Pseudomonas aeruginosa: A Focused Review

Pseudomonas aeruginosa (PA) is a pathogen that is recognized for its advanced antibiotic resistance and its association with serious diseases such as ventilator-associated pneumonia and cystic fibrosis. The ability to rapidly detect the presence of pathogenic bacteria in patient samples is crucial f...

Descripción completa

Detalles Bibliográficos
Autores principales: Alatraktchi, Fatima AlZahra’a, Svendsen, Winnie E., Molin, Søren
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7570525/
https://www.ncbi.nlm.nih.gov/pubmed/32933125
http://dx.doi.org/10.3390/s20185218
_version_ 1783596966889914368
author Alatraktchi, Fatima AlZahra’a
Svendsen, Winnie E.
Molin, Søren
author_facet Alatraktchi, Fatima AlZahra’a
Svendsen, Winnie E.
Molin, Søren
author_sort Alatraktchi, Fatima AlZahra’a
collection PubMed
description Pseudomonas aeruginosa (PA) is a pathogen that is recognized for its advanced antibiotic resistance and its association with serious diseases such as ventilator-associated pneumonia and cystic fibrosis. The ability to rapidly detect the presence of pathogenic bacteria in patient samples is crucial for the immediate eradication of the infection. Pyocyanin is one of PA’s virulence factors used to establish infections. Pyocyanin promotes virulence by interfering in numerous cellular functions in host cells due to its redox-activity. Fortunately, the redox-active nature of pyocyanin makes it ideal for detection with simple electrochemical techniques without sample pretreatment or sensor functionalization. The previous decade has seen an increased interest in the electrochemical detection of pyocyanin either as an indicator of the presence of PA in samples or as a tool for quantifying PA virulence. This review provides the first overview of the advances in electrochemical detection of pyocyanin and offers an input regarding the future directions in the field.
format Online
Article
Text
id pubmed-7570525
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-75705252020-10-28 Electrochemical Detection of Pyocyanin as a Biomarker for Pseudomonas aeruginosa: A Focused Review Alatraktchi, Fatima AlZahra’a Svendsen, Winnie E. Molin, Søren Sensors (Basel) Review Pseudomonas aeruginosa (PA) is a pathogen that is recognized for its advanced antibiotic resistance and its association with serious diseases such as ventilator-associated pneumonia and cystic fibrosis. The ability to rapidly detect the presence of pathogenic bacteria in patient samples is crucial for the immediate eradication of the infection. Pyocyanin is one of PA’s virulence factors used to establish infections. Pyocyanin promotes virulence by interfering in numerous cellular functions in host cells due to its redox-activity. Fortunately, the redox-active nature of pyocyanin makes it ideal for detection with simple electrochemical techniques without sample pretreatment or sensor functionalization. The previous decade has seen an increased interest in the electrochemical detection of pyocyanin either as an indicator of the presence of PA in samples or as a tool for quantifying PA virulence. This review provides the first overview of the advances in electrochemical detection of pyocyanin and offers an input regarding the future directions in the field. MDPI 2020-09-13 /pmc/articles/PMC7570525/ /pubmed/32933125 http://dx.doi.org/10.3390/s20185218 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Review
Alatraktchi, Fatima AlZahra’a
Svendsen, Winnie E.
Molin, Søren
Electrochemical Detection of Pyocyanin as a Biomarker for Pseudomonas aeruginosa: A Focused Review
title Electrochemical Detection of Pyocyanin as a Biomarker for Pseudomonas aeruginosa: A Focused Review
title_full Electrochemical Detection of Pyocyanin as a Biomarker for Pseudomonas aeruginosa: A Focused Review
title_fullStr Electrochemical Detection of Pyocyanin as a Biomarker for Pseudomonas aeruginosa: A Focused Review
title_full_unstemmed Electrochemical Detection of Pyocyanin as a Biomarker for Pseudomonas aeruginosa: A Focused Review
title_short Electrochemical Detection of Pyocyanin as a Biomarker for Pseudomonas aeruginosa: A Focused Review
title_sort electrochemical detection of pyocyanin as a biomarker for pseudomonas aeruginosa: a focused review
topic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7570525/
https://www.ncbi.nlm.nih.gov/pubmed/32933125
http://dx.doi.org/10.3390/s20185218
work_keys_str_mv AT alatraktchifatimaalzahraa electrochemicaldetectionofpyocyaninasabiomarkerforpseudomonasaeruginosaafocusedreview
AT svendsenwinniee electrochemicaldetectionofpyocyaninasabiomarkerforpseudomonasaeruginosaafocusedreview
AT molinsøren electrochemicaldetectionofpyocyaninasabiomarkerforpseudomonasaeruginosaafocusedreview