Flunitrazepam is an extremely potent benzodiazepine sedative which is associated with “drug-facilitated sexual assault” when administered within an alcoholic drink. This work describes a simple electrochemical method for on-site rapid detection of flunitrazepam in untreated spirits (whiskey, vodka a...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7570630/ https://www.ncbi.nlm.nih.gov/pubmed/32933037 http://dx.doi.org/10.3390/s20185192 |
_version_ | 1783596991307055104 |
---|---|
author | Papadopoulos, Frixos Diamanteas, Konstantinos Economou, Anastasios Kokkinos, Christos |
author_facet | Papadopoulos, Frixos Diamanteas, Konstantinos Economou, Anastasios Kokkinos, Christos |
author_sort | Papadopoulos, Frixos |
collection | PubMed |
description | Flunitrazepam is an extremely potent benzodiazepine sedative which is associated with “drug-facilitated sexual assault” when administered within an alcoholic drink. This work describes a simple electrochemical method for on-site rapid detection of flunitrazepam in untreated spirits (whiskey, vodka and gin) using a single-use screen-printed sensor (featuring graphite working and auxiliary electrodes and an Ag/AgCl reference electrode) in a dry reagent format. Analysis was performed by placing a drop of sample on the sensor, which was previously coated with dry KCl, and recording selected reduction/oxidation peaks of the target compound in a cyclic voltammetry scan. The limit of quantification of flunitrazepam was at the sub-mg L(−1) range. The between-sensor % relative standard deviation of the analytically useful reduction peak in a solution containing 11.4 mg L(−1) flunitrazepam was 9.8% (n = 5). Quantification was performed using calibration curves constructed from pooled samples spiked with flunitrazepam with relative errors <15%. The main advantages of the methodology are that it involves no sample pretreatment (such as deoxygenation, extraction or reagent(s) addition) and requires only drop-sized volumes of the sample, thus facilitating rapid on-site screening using portable equipment. |
format | Online Article Text |
id | pubmed-7570630 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-75706302020-10-28 Rapid Drop-Volume Electrochemical Detection of the “Date Rape” Drug Flunitrazepam in Spirits Using a Screen-Printed Sensor in a Dry-Reagent Format Papadopoulos, Frixos Diamanteas, Konstantinos Economou, Anastasios Kokkinos, Christos Sensors (Basel) Letter Flunitrazepam is an extremely potent benzodiazepine sedative which is associated with “drug-facilitated sexual assault” when administered within an alcoholic drink. This work describes a simple electrochemical method for on-site rapid detection of flunitrazepam in untreated spirits (whiskey, vodka and gin) using a single-use screen-printed sensor (featuring graphite working and auxiliary electrodes and an Ag/AgCl reference electrode) in a dry reagent format. Analysis was performed by placing a drop of sample on the sensor, which was previously coated with dry KCl, and recording selected reduction/oxidation peaks of the target compound in a cyclic voltammetry scan. The limit of quantification of flunitrazepam was at the sub-mg L(−1) range. The between-sensor % relative standard deviation of the analytically useful reduction peak in a solution containing 11.4 mg L(−1) flunitrazepam was 9.8% (n = 5). Quantification was performed using calibration curves constructed from pooled samples spiked with flunitrazepam with relative errors <15%. The main advantages of the methodology are that it involves no sample pretreatment (such as deoxygenation, extraction or reagent(s) addition) and requires only drop-sized volumes of the sample, thus facilitating rapid on-site screening using portable equipment. MDPI 2020-09-11 /pmc/articles/PMC7570630/ /pubmed/32933037 http://dx.doi.org/10.3390/s20185192 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Letter Papadopoulos, Frixos Diamanteas, Konstantinos Economou, Anastasios Kokkinos, Christos Rapid Drop-Volume Electrochemical Detection of the “Date Rape” Drug Flunitrazepam in Spirits Using a Screen-Printed Sensor in a Dry-Reagent Format |
title | Rapid Drop-Volume Electrochemical Detection of the “Date Rape” Drug Flunitrazepam in Spirits Using a Screen-Printed Sensor in a Dry-Reagent Format |
title_full | Rapid Drop-Volume Electrochemical Detection of the “Date Rape” Drug Flunitrazepam in Spirits Using a Screen-Printed Sensor in a Dry-Reagent Format |
title_fullStr | Rapid Drop-Volume Electrochemical Detection of the “Date Rape” Drug Flunitrazepam in Spirits Using a Screen-Printed Sensor in a Dry-Reagent Format |
title_full_unstemmed | Rapid Drop-Volume Electrochemical Detection of the “Date Rape” Drug Flunitrazepam in Spirits Using a Screen-Printed Sensor in a Dry-Reagent Format |
title_short | Rapid Drop-Volume Electrochemical Detection of the “Date Rape” Drug Flunitrazepam in Spirits Using a Screen-Printed Sensor in a Dry-Reagent Format |
title_sort | rapid drop-volume electrochemical detection of the “date rape” drug flunitrazepam in spirits using a screen-printed sensor in a dry-reagent format |
topic | Letter |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7570630/ https://www.ncbi.nlm.nih.gov/pubmed/32933037 http://dx.doi.org/10.3390/s20185192 |
work_keys_str_mv | AT papadopoulosfrixos rapiddropvolumeelectrochemicaldetectionofthedaterapedrugflunitrazepaminspiritsusingascreenprintedsensorinadryreagentformat AT diamanteaskonstantinos rapiddropvolumeelectrochemicaldetectionofthedaterapedrugflunitrazepaminspiritsusingascreenprintedsensorinadryreagentformat AT economouanastasios rapiddropvolumeelectrochemicaldetectionofthedaterapedrugflunitrazepaminspiritsusingascreenprintedsensorinadryreagentformat AT kokkinoschristos rapiddropvolumeelectrochemicaldetectionofthedaterapedrugflunitrazepaminspiritsusingascreenprintedsensorinadryreagentformat |