Bloch Surface Wave Resonance Based Sensors as an Alternative to Surface Plasmon Resonance Sensors

We report on a highly sensitive measurement of the relative humidity (RH) of moist air using both the surface plasmon resonance (SPR) and Bloch surface wave resonance (BSWR). Both resonances are resolved in the Kretschmann configuration when the wavelength interrogation method is utilized. The SPR i...

Descripción completa

Detalles Bibliográficos
Autores principales: Gryga, Michal, Ciprian, Dalibor, Hlubina, Petr
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7570763/
https://www.ncbi.nlm.nih.gov/pubmed/32911784
http://dx.doi.org/10.3390/s20185119
Descripción
Sumario:We report on a highly sensitive measurement of the relative humidity (RH) of moist air using both the surface plasmon resonance (SPR) and Bloch surface wave resonance (BSWR). Both resonances are resolved in the Kretschmann configuration when the wavelength interrogation method is utilized. The SPR is revealed for a multilayer plasmonic structure of SF10/Cr/Au, while the BSWR is resolved for a multilayer dielectric structure (MDS) comprising four bilayers of TiO [Formula: see text] /SiO [Formula: see text] with a rough termination layer of TiO [Formula: see text]. The SPR effect is manifested by a dip in the reflectance of a p-polarized wave, and a shift of the dip with the change in the RH, or equivalently with the change in the refractive index of moist air is revealed, giving a sensitivity in a range of 0.042–0.072 nm/%RH. The BSWR effect is manifested by a dip in the reflectance of the spectral interference of s- and p-polarized waves, which represents an effective approach in resolving the resonance with maximum depth. For the MDS under study, the BSWRs were resolved within two band gaps, and for moist air we obtained sensitivities of 0.021–0.038 nm/%RH and 0.046–0.065 nm/%RH, respectively. We also revealed that the SPR based RH measurement is with the figure of merit (FOM) up to 4.7 × 10(−4) %RH [Formula: see text] , while BSWR based measurements have FOMs as high as 3.0 × 10 [Formula: see text] %RH [Formula: see text] and 1.1 × 10(−3) %RH [Formula: see text] , respectively. The obtained spectral interferometry based results demonstrate that the BSWR based sensor employing the available MDS has a similar sensitivity as the SPR based sensor, but outperforms it in the FOM. BSW based sensors employing dielectrics thus represent an effective alternative with a number of advantages, including better mechanical and chemical stability than metal films used in SPR sensing.