Salinity Independent Flow Measurement of Vertical Upward Gas-Liquid Flows in a Small Pipe Using Conductance Method

Flow measurement in gas-liquid two-phase flow is always a challenging work, because of the non-uniform phase distribution, severe slippage effect between phases, and different flow structures. Furthermore, the variation of salinity changes the water conductivity, which brings more difficulties to mu...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Dayang, Jin, Ningde, Zhai, Lusheng, Ren, Yingyu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7570925/
https://www.ncbi.nlm.nih.gov/pubmed/32942591
http://dx.doi.org/10.3390/s20185263
_version_ 1783597059690987520
author Wang, Dayang
Jin, Ningde
Zhai, Lusheng
Ren, Yingyu
author_facet Wang, Dayang
Jin, Ningde
Zhai, Lusheng
Ren, Yingyu
author_sort Wang, Dayang
collection PubMed
description Flow measurement in gas-liquid two-phase flow is always a challenging work, because of the non-uniform phase distribution, severe slippage effect between phases, and different flow structures. Furthermore, the variation of salinity changes the water conductivity, which brings more difficulties to multiphase flow measurement. In this study, a methodology for flow measurement using the conductance method in gas-liquid two-phase flow with salinity change is proposed. The methodology includes the suitable conductivity detection method, the strategy of using combined sensors, and the measurement models of flow parameters. A suitable conductivity detection method that can guarantee that the sensor output is linearly proportional to the conductivity is proposed. This conductivity detection method can ensure that the sensors have a high and constant resolution in the conductivity variation caused by water holdup under the conditions of water conductivity change. Afterward, a combined sensor system consisting of a water holdup sensor, velocity sensor, and water conductivity sensor is designed and experimentally evaluated in gas-water two-phase flow in a 20 mm inner diameter pipe. Considering the non-uniform phase distribution, severe slippage effect between phases, different flow structures, and the variation of salinity, a new water holdup measurement model and flow velocity measurement models are established to achieve salinity independent water holdup measurement and flow velocity measurement for the first time.
format Online
Article
Text
id pubmed-7570925
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-75709252020-10-28 Salinity Independent Flow Measurement of Vertical Upward Gas-Liquid Flows in a Small Pipe Using Conductance Method Wang, Dayang Jin, Ningde Zhai, Lusheng Ren, Yingyu Sensors (Basel) Article Flow measurement in gas-liquid two-phase flow is always a challenging work, because of the non-uniform phase distribution, severe slippage effect between phases, and different flow structures. Furthermore, the variation of salinity changes the water conductivity, which brings more difficulties to multiphase flow measurement. In this study, a methodology for flow measurement using the conductance method in gas-liquid two-phase flow with salinity change is proposed. The methodology includes the suitable conductivity detection method, the strategy of using combined sensors, and the measurement models of flow parameters. A suitable conductivity detection method that can guarantee that the sensor output is linearly proportional to the conductivity is proposed. This conductivity detection method can ensure that the sensors have a high and constant resolution in the conductivity variation caused by water holdup under the conditions of water conductivity change. Afterward, a combined sensor system consisting of a water holdup sensor, velocity sensor, and water conductivity sensor is designed and experimentally evaluated in gas-water two-phase flow in a 20 mm inner diameter pipe. Considering the non-uniform phase distribution, severe slippage effect between phases, different flow structures, and the variation of salinity, a new water holdup measurement model and flow velocity measurement models are established to achieve salinity independent water holdup measurement and flow velocity measurement for the first time. MDPI 2020-09-15 /pmc/articles/PMC7570925/ /pubmed/32942591 http://dx.doi.org/10.3390/s20185263 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Wang, Dayang
Jin, Ningde
Zhai, Lusheng
Ren, Yingyu
Salinity Independent Flow Measurement of Vertical Upward Gas-Liquid Flows in a Small Pipe Using Conductance Method
title Salinity Independent Flow Measurement of Vertical Upward Gas-Liquid Flows in a Small Pipe Using Conductance Method
title_full Salinity Independent Flow Measurement of Vertical Upward Gas-Liquid Flows in a Small Pipe Using Conductance Method
title_fullStr Salinity Independent Flow Measurement of Vertical Upward Gas-Liquid Flows in a Small Pipe Using Conductance Method
title_full_unstemmed Salinity Independent Flow Measurement of Vertical Upward Gas-Liquid Flows in a Small Pipe Using Conductance Method
title_short Salinity Independent Flow Measurement of Vertical Upward Gas-Liquid Flows in a Small Pipe Using Conductance Method
title_sort salinity independent flow measurement of vertical upward gas-liquid flows in a small pipe using conductance method
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7570925/
https://www.ncbi.nlm.nih.gov/pubmed/32942591
http://dx.doi.org/10.3390/s20185263
work_keys_str_mv AT wangdayang salinityindependentflowmeasurementofverticalupwardgasliquidflowsinasmallpipeusingconductancemethod
AT jinningde salinityindependentflowmeasurementofverticalupwardgasliquidflowsinasmallpipeusingconductancemethod
AT zhailusheng salinityindependentflowmeasurementofverticalupwardgasliquidflowsinasmallpipeusingconductancemethod
AT renyingyu salinityindependentflowmeasurementofverticalupwardgasliquidflowsinasmallpipeusingconductancemethod