Cargando…

Ocular Surface Potential Difference Measured in Human Subjects to Study Ocular Surface Ion Transport

PURPOSE: The epithelium lining the ocular surface, which includes corneal and conjunctival epithelia, expresses the prosecretory chloride channel cystic fibrosis transmembrane conductance regulator (CFTR) and the proabsorptive epithelial sodium channel (ENaC). Here, methodology was established to me...

Descripción completa

Detalles Bibliográficos
Autores principales: Pasricha, Neel D., Smith, Alex J., Levin, Marc H., Schallhorn, Julie M., Verkman, Alan S.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Association for Research in Vision and Ophthalmology 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7571274/
https://www.ncbi.nlm.nih.gov/pubmed/33117611
http://dx.doi.org/10.1167/tvst.9.11.20
_version_ 1783597138742083584
author Pasricha, Neel D.
Smith, Alex J.
Levin, Marc H.
Schallhorn, Julie M.
Verkman, Alan S.
author_facet Pasricha, Neel D.
Smith, Alex J.
Levin, Marc H.
Schallhorn, Julie M.
Verkman, Alan S.
author_sort Pasricha, Neel D.
collection PubMed
description PURPOSE: The epithelium lining the ocular surface, which includes corneal and conjunctival epithelia, expresses the prosecretory chloride channel cystic fibrosis transmembrane conductance regulator (CFTR) and the proabsorptive epithelial sodium channel (ENaC). Here, methodology was established to measure the millivolt (mV) potential differences at the ocular surface, called ocular surface potential difference (OSPD), in human subjects produced by ion transport. METHODS: OSPD was measured in human subjects in which a fluid-filled measuring electrode contacted a fluid pool created by eversion of the lateral lower eyelid, with a reference electrode placed subcutaneously in the forearm. Through the use of a high-impedance voltmeter, OSPD was measured continuously over 10 to 15 minutes in response to a series of perfusate fluid exchanges. RESULTS: Baseline OSPD (± SEM) in six normal human subjects was –21.3 ± 3.6 mV. OSPD depolarized by 1.7 ± 0.6 mV following the addition of the ENaC inhibitor amiloride, hyperpolarized by 6.8 ± 1.5 mV with a zero chloride solution, and further hyperpolarized by 15.9 ± 1.6 mV following CFTR activation by isoproterenol. The isoproterenol-induced hyperpolarization was absent in two cystic fibrosis subjects lacking functional CFTR. OSPD measurement produced minimal epithelial injury. CONCLUSIONS: Our results establish the feasibility and safety of OSPD measurement in humans and demonstrate robust CFTR activity, albeit minimal ENaC activity, at the ocular surface. OSPD measurement may be broadly applicable to investigate fluid transport mechanisms and test drug candidates to treat ocular surface disorders. TRANSLATIONAL RELEVANCE: To the best of our knowledge, this is the first measurement of the electrical potential generated by the ocular surface epithelium in human subjects, offering a new approach to study ocular surface function and health.
format Online
Article
Text
id pubmed-7571274
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher The Association for Research in Vision and Ophthalmology
record_format MEDLINE/PubMed
spelling pubmed-75712742020-10-27 Ocular Surface Potential Difference Measured in Human Subjects to Study Ocular Surface Ion Transport Pasricha, Neel D. Smith, Alex J. Levin, Marc H. Schallhorn, Julie M. Verkman, Alan S. Transl Vis Sci Technol Article PURPOSE: The epithelium lining the ocular surface, which includes corneal and conjunctival epithelia, expresses the prosecretory chloride channel cystic fibrosis transmembrane conductance regulator (CFTR) and the proabsorptive epithelial sodium channel (ENaC). Here, methodology was established to measure the millivolt (mV) potential differences at the ocular surface, called ocular surface potential difference (OSPD), in human subjects produced by ion transport. METHODS: OSPD was measured in human subjects in which a fluid-filled measuring electrode contacted a fluid pool created by eversion of the lateral lower eyelid, with a reference electrode placed subcutaneously in the forearm. Through the use of a high-impedance voltmeter, OSPD was measured continuously over 10 to 15 minutes in response to a series of perfusate fluid exchanges. RESULTS: Baseline OSPD (± SEM) in six normal human subjects was –21.3 ± 3.6 mV. OSPD depolarized by 1.7 ± 0.6 mV following the addition of the ENaC inhibitor amiloride, hyperpolarized by 6.8 ± 1.5 mV with a zero chloride solution, and further hyperpolarized by 15.9 ± 1.6 mV following CFTR activation by isoproterenol. The isoproterenol-induced hyperpolarization was absent in two cystic fibrosis subjects lacking functional CFTR. OSPD measurement produced minimal epithelial injury. CONCLUSIONS: Our results establish the feasibility and safety of OSPD measurement in humans and demonstrate robust CFTR activity, albeit minimal ENaC activity, at the ocular surface. OSPD measurement may be broadly applicable to investigate fluid transport mechanisms and test drug candidates to treat ocular surface disorders. TRANSLATIONAL RELEVANCE: To the best of our knowledge, this is the first measurement of the electrical potential generated by the ocular surface epithelium in human subjects, offering a new approach to study ocular surface function and health. The Association for Research in Vision and Ophthalmology 2020-10-15 /pmc/articles/PMC7571274/ /pubmed/33117611 http://dx.doi.org/10.1167/tvst.9.11.20 Text en Copyright 2020 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
spellingShingle Article
Pasricha, Neel D.
Smith, Alex J.
Levin, Marc H.
Schallhorn, Julie M.
Verkman, Alan S.
Ocular Surface Potential Difference Measured in Human Subjects to Study Ocular Surface Ion Transport
title Ocular Surface Potential Difference Measured in Human Subjects to Study Ocular Surface Ion Transport
title_full Ocular Surface Potential Difference Measured in Human Subjects to Study Ocular Surface Ion Transport
title_fullStr Ocular Surface Potential Difference Measured in Human Subjects to Study Ocular Surface Ion Transport
title_full_unstemmed Ocular Surface Potential Difference Measured in Human Subjects to Study Ocular Surface Ion Transport
title_short Ocular Surface Potential Difference Measured in Human Subjects to Study Ocular Surface Ion Transport
title_sort ocular surface potential difference measured in human subjects to study ocular surface ion transport
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7571274/
https://www.ncbi.nlm.nih.gov/pubmed/33117611
http://dx.doi.org/10.1167/tvst.9.11.20
work_keys_str_mv AT pasrichaneeld ocularsurfacepotentialdifferencemeasuredinhumansubjectstostudyocularsurfaceiontransport
AT smithalexj ocularsurfacepotentialdifferencemeasuredinhumansubjectstostudyocularsurfaceiontransport
AT levinmarch ocularsurfacepotentialdifferencemeasuredinhumansubjectstostudyocularsurfaceiontransport
AT schallhornjuliem ocularsurfacepotentialdifferencemeasuredinhumansubjectstostudyocularsurfaceiontransport
AT verkmanalans ocularsurfacepotentialdifferencemeasuredinhumansubjectstostudyocularsurfaceiontransport