Cargando…

Observation of hemodynamic parameters using a non-invasive cardiac output monitor system to identify predictive indicators for post-spinal anesthesia hypotension in parturients undergoing cesarean section

The administration of high-level spinal anesthesia for cesarean section may lead to significant hemodynamic changes. Bioreactance-based non-invasive cardiac output monitoring (NICOM(™)) provides an accurate monitoring system for parturients under spinal anesthesia. The present study hypothesized tha...

Descripción completa

Detalles Bibliográficos
Autores principales: Yeh, Pin-Hung, Chang, Yu-Jun, Tsai, Sheng-En
Formato: Online Artículo Texto
Lenguaje:English
Publicado: D.A. Spandidos 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7571406/
https://www.ncbi.nlm.nih.gov/pubmed/33093906
http://dx.doi.org/10.3892/etm.2020.9298
_version_ 1783597166208483328
author Yeh, Pin-Hung
Chang, Yu-Jun
Tsai, Sheng-En
author_facet Yeh, Pin-Hung
Chang, Yu-Jun
Tsai, Sheng-En
author_sort Yeh, Pin-Hung
collection PubMed
description The administration of high-level spinal anesthesia for cesarean section may lead to significant hemodynamic changes. Bioreactance-based non-invasive cardiac output monitoring (NICOM(™)) provides an accurate monitoring system for parturients under spinal anesthesia. The present study hypothesized that baseline hemodynamic parameters obtained via the NICOM(™) system could serve as predictive indicators for post-spinal anesthesia hypotension. Therefore, 80 full-term parturients with singleton pregnancies who underwent scheduled cesarean section were enrolled and allocated to either a supine position group or a 15˚ left tilt group. All parturients received standard pre-hydration with 750 ml of 0.9% saline. Baseline cardiac output index (CI), total peripheral resistance index (TPRI) and stroke volume (SV) were recorded using the NICOM(™) system. Subsequently, spinal anesthesia with 2.4 ml of 0.5% hyperbaric bupivacaine, 10 µg of fentanyl and 0.2 mg of morphine was administered. Receiver operating characteristic (ROC) curves and multivariate logistic regression were used to analyze the data. A total of 40 parturients (51.9%) developed hypotension. The areas under the ROC curves were 0.666, 0.594 and 0.622 for the CI, TPRI and SV, respectively. The optimal cut-off value of the CI in predicting hypotension was 3.68 l/min/m(2) (ROC, sensitivity=85.0%, specificity=48.6%). Furthermore, CI was considered as an independent factor for post-spinal anesthesia hypotension. In conclusion, the baseline CI obtained via the bioreactance-based NICOM(™) system may serve as a predictor of post-spinal anesthesia hypotension in parturients regardless of patient position.
format Online
Article
Text
id pubmed-7571406
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher D.A. Spandidos
record_format MEDLINE/PubMed
spelling pubmed-75714062020-10-21 Observation of hemodynamic parameters using a non-invasive cardiac output monitor system to identify predictive indicators for post-spinal anesthesia hypotension in parturients undergoing cesarean section Yeh, Pin-Hung Chang, Yu-Jun Tsai, Sheng-En Exp Ther Med Articles The administration of high-level spinal anesthesia for cesarean section may lead to significant hemodynamic changes. Bioreactance-based non-invasive cardiac output monitoring (NICOM(™)) provides an accurate monitoring system for parturients under spinal anesthesia. The present study hypothesized that baseline hemodynamic parameters obtained via the NICOM(™) system could serve as predictive indicators for post-spinal anesthesia hypotension. Therefore, 80 full-term parturients with singleton pregnancies who underwent scheduled cesarean section were enrolled and allocated to either a supine position group or a 15˚ left tilt group. All parturients received standard pre-hydration with 750 ml of 0.9% saline. Baseline cardiac output index (CI), total peripheral resistance index (TPRI) and stroke volume (SV) were recorded using the NICOM(™) system. Subsequently, spinal anesthesia with 2.4 ml of 0.5% hyperbaric bupivacaine, 10 µg of fentanyl and 0.2 mg of morphine was administered. Receiver operating characteristic (ROC) curves and multivariate logistic regression were used to analyze the data. A total of 40 parturients (51.9%) developed hypotension. The areas under the ROC curves were 0.666, 0.594 and 0.622 for the CI, TPRI and SV, respectively. The optimal cut-off value of the CI in predicting hypotension was 3.68 l/min/m(2) (ROC, sensitivity=85.0%, specificity=48.6%). Furthermore, CI was considered as an independent factor for post-spinal anesthesia hypotension. In conclusion, the baseline CI obtained via the bioreactance-based NICOM(™) system may serve as a predictor of post-spinal anesthesia hypotension in parturients regardless of patient position. D.A. Spandidos 2020-12 2020-10-09 /pmc/articles/PMC7571406/ /pubmed/33093906 http://dx.doi.org/10.3892/etm.2020.9298 Text en Copyright: © Yeh et al. This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs License (https://creativecommons.org/licenses/by-nc-nd/4.0/) , which permits use and distribution in any medium, provided the original work is properly cited, the use is non-commercial and no modifications or adaptations are made.
spellingShingle Articles
Yeh, Pin-Hung
Chang, Yu-Jun
Tsai, Sheng-En
Observation of hemodynamic parameters using a non-invasive cardiac output monitor system to identify predictive indicators for post-spinal anesthesia hypotension in parturients undergoing cesarean section
title Observation of hemodynamic parameters using a non-invasive cardiac output monitor system to identify predictive indicators for post-spinal anesthesia hypotension in parturients undergoing cesarean section
title_full Observation of hemodynamic parameters using a non-invasive cardiac output monitor system to identify predictive indicators for post-spinal anesthesia hypotension in parturients undergoing cesarean section
title_fullStr Observation of hemodynamic parameters using a non-invasive cardiac output monitor system to identify predictive indicators for post-spinal anesthesia hypotension in parturients undergoing cesarean section
title_full_unstemmed Observation of hemodynamic parameters using a non-invasive cardiac output monitor system to identify predictive indicators for post-spinal anesthesia hypotension in parturients undergoing cesarean section
title_short Observation of hemodynamic parameters using a non-invasive cardiac output monitor system to identify predictive indicators for post-spinal anesthesia hypotension in parturients undergoing cesarean section
title_sort observation of hemodynamic parameters using a non-invasive cardiac output monitor system to identify predictive indicators for post-spinal anesthesia hypotension in parturients undergoing cesarean section
topic Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7571406/
https://www.ncbi.nlm.nih.gov/pubmed/33093906
http://dx.doi.org/10.3892/etm.2020.9298
work_keys_str_mv AT yehpinhung observationofhemodynamicparametersusinganoninvasivecardiacoutputmonitorsystemtoidentifypredictiveindicatorsforpostspinalanesthesiahypotensioninparturientsundergoingcesareansection
AT changyujun observationofhemodynamicparametersusinganoninvasivecardiacoutputmonitorsystemtoidentifypredictiveindicatorsforpostspinalanesthesiahypotensioninparturientsundergoingcesareansection
AT tsaishengen observationofhemodynamicparametersusinganoninvasivecardiacoutputmonitorsystemtoidentifypredictiveindicatorsforpostspinalanesthesiahypotensioninparturientsundergoingcesareansection