Cargando…

Safety of EUS-guided gallbladder drainage using a lumen-apposing metal stent in patients requiring anticoagulation

BACKGROUND AND AIMS: EUS-guided gallbladder drainage (EUS-GBD) can be used to treat acute cholecystitis in patients with medical comorbidities that prevent definitive operative management. Historically, nonsurgical management of cholecystitis was achieved by way of percutaneous gallbladder drainage....

Descripción completa

Detalles Bibliográficos
Autores principales: Vozzo, Catherine Frakes, Simons-Linares, C. Roberto, Abou Saleh, Mohannad, Stevens, Tyler, Chahal, Prabhleen
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7572616/
https://www.ncbi.nlm.nih.gov/pubmed/33103010
http://dx.doi.org/10.1016/j.vgie.2020.07.009
Descripción
Sumario:BACKGROUND AND AIMS: EUS-guided gallbladder drainage (EUS-GBD) can be used to treat acute cholecystitis in patients with medical comorbidities that prevent definitive operative management. Historically, nonsurgical management of cholecystitis was achieved by way of percutaneous gallbladder drainage. METHODS: We examined the periprocedural bleeding rate of EUS-GBD for acute cholecystitis using lumen-apposing metal stents in 5 high-surgical-risk patients requiring anticoagulation. Data on 5 nonoperative candidates with acute cholecystitis who underwent EUS-GBD were studied retrospectively. RESULTS: There were no immediate or delayed postprocedure adverse events, including bleeding. CONCLUSIONS: Although further study is needed, EUS-GBD appears safe in patients who require periprocedural anticoagulation.