An anterior segment optical coherence tomography study of the anterior chamber angle after implantable collamer lens-V4c implantation in Asian Indian Eyes

PURPOSE: To quantitatively assess anterior chamber and angle parameters by anterior segment optical coherence tomography (AS-OCT) in myopic eyes undergoing Implantable Collamer Lens (ICL V4c) implantation. METHODS: Prospective noncomparative observational case series. Pre and postoperative (1(st) an...

Descripción completa

Detalles Bibliográficos
Autores principales: Singh, Rashmi, Vanathi, Murugesan, Kishore, Alisha, Tandon, Radhika, Singh, Divya
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7574076/
https://www.ncbi.nlm.nih.gov/pubmed/32587181
http://dx.doi.org/10.4103/ijo.IJO_1540_19
_version_ 1783597568485228544
author Singh, Rashmi
Vanathi, Murugesan
Kishore, Alisha
Tandon, Radhika
Singh, Divya
author_facet Singh, Rashmi
Vanathi, Murugesan
Kishore, Alisha
Tandon, Radhika
Singh, Divya
author_sort Singh, Rashmi
collection PubMed
description PURPOSE: To quantitatively assess anterior chamber and angle parameters by anterior segment optical coherence tomography (AS-OCT) in myopic eyes undergoing Implantable Collamer Lens (ICL V4c) implantation. METHODS: Prospective noncomparative observational case series. Pre and postoperative (1(st) and 3(rd) month) AS-OCT angle parameters (anterior chamber depth [ACD], anterior chamber angle [ACA], Angle opening distance [AOD], trabecular iris space area [TISA], scleral spur angle [SSA]) were evaluated in 32 eyes (16 patients). SPSS version 20 with paired t-test for intragroup and Mann-Whitney U value test for intergroup comparisons. RESULTS: It included 6 (37.5%) males and 10 (62.5%) females. Preoperative ACA of 34.6 ± 2.3° reduced to 32.2 ± 2.4°, 31.9 ± 2.5° at 1 and 3 months postoperatively (P = 0.001). Preoperative mean AOD500, AOD750, TISA500, TISA750, SSA of 0.34 ± 0.06 mm, 0.52 ± 0.15 mm, 0.09 ± 0.02 mm(2), 0.20 ± 0.04 mm(2), 34.27 ± 4.6° decreased to 0.32 ± 0.06 mm, 0.48 ± 0.15 mm, 0.08 ± 0.02 mm(2), 0.17 ± 0.05 mm(2), 32.5 ± 4.3° at 1-month (P = 0.001); 0.32 ± 0.06 mm, 0.47 ± 0.13 mm, 0.08 ± 0.02 mm(2), 0.17 ± 0.05 mm(2) and 32.4 ± 4.6° (P = 0.001) at 3-months, respectively. Correlation analysis between preoperative ACD/intraocular pressure (IOP) was − 0.62 (P = 0.0002) [1(st) month], −0.40 (0.024) [third month]; between IOP/postoperative ACA, AOD500, AOD750, TISA500, TISA750, SSA was − 0.04 (0.81), −0.03 (0.85), −0.08 (0.64), −0.12 (0.48), −0.10 (0.57), −0.06 (0.73) at 1 month; −0.09 (0.58), 0.04 (0.78), 0.12 (0.48), −0.02 (0.9), −0.04 (0.79), 0.02 (0.88) at 3 months; between ICL vault/ACA, AOD500, AOD750, TISA500, TISA750, SSA was 0.38 (0.02), 0.24 (0.17), 0.21 (0.25), 0.05 (0.75), 0.15 (0.41), 0.27 (0.13) at 1(st) month; 0.19 (0.28), 0.06 (0.71), −0.03 (0.85), 0.005 (0.97), 0.05 (0.78), 0.07 (0.68) at 3(rd) month. CONCLUSION: Postoperatively significant angle narrowing was noted. There was a negative correlation between IOP and preoperative ACD. There was no significant correlation between IOP and ICL vault with postoperative AS-OCT angle parameters.
format Online
Article
Text
id pubmed-7574076
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-75740762020-10-22 An anterior segment optical coherence tomography study of the anterior chamber angle after implantable collamer lens-V4c implantation in Asian Indian Eyes Singh, Rashmi Vanathi, Murugesan Kishore, Alisha Tandon, Radhika Singh, Divya Indian J Ophthalmol Original Article PURPOSE: To quantitatively assess anterior chamber and angle parameters by anterior segment optical coherence tomography (AS-OCT) in myopic eyes undergoing Implantable Collamer Lens (ICL V4c) implantation. METHODS: Prospective noncomparative observational case series. Pre and postoperative (1(st) and 3(rd) month) AS-OCT angle parameters (anterior chamber depth [ACD], anterior chamber angle [ACA], Angle opening distance [AOD], trabecular iris space area [TISA], scleral spur angle [SSA]) were evaluated in 32 eyes (16 patients). SPSS version 20 with paired t-test for intragroup and Mann-Whitney U value test for intergroup comparisons. RESULTS: It included 6 (37.5%) males and 10 (62.5%) females. Preoperative ACA of 34.6 ± 2.3° reduced to 32.2 ± 2.4°, 31.9 ± 2.5° at 1 and 3 months postoperatively (P = 0.001). Preoperative mean AOD500, AOD750, TISA500, TISA750, SSA of 0.34 ± 0.06 mm, 0.52 ± 0.15 mm, 0.09 ± 0.02 mm(2), 0.20 ± 0.04 mm(2), 34.27 ± 4.6° decreased to 0.32 ± 0.06 mm, 0.48 ± 0.15 mm, 0.08 ± 0.02 mm(2), 0.17 ± 0.05 mm(2), 32.5 ± 4.3° at 1-month (P = 0.001); 0.32 ± 0.06 mm, 0.47 ± 0.13 mm, 0.08 ± 0.02 mm(2), 0.17 ± 0.05 mm(2) and 32.4 ± 4.6° (P = 0.001) at 3-months, respectively. Correlation analysis between preoperative ACD/intraocular pressure (IOP) was − 0.62 (P = 0.0002) [1(st) month], −0.40 (0.024) [third month]; between IOP/postoperative ACA, AOD500, AOD750, TISA500, TISA750, SSA was − 0.04 (0.81), −0.03 (0.85), −0.08 (0.64), −0.12 (0.48), −0.10 (0.57), −0.06 (0.73) at 1 month; −0.09 (0.58), 0.04 (0.78), 0.12 (0.48), −0.02 (0.9), −0.04 (0.79), 0.02 (0.88) at 3 months; between ICL vault/ACA, AOD500, AOD750, TISA500, TISA750, SSA was 0.38 (0.02), 0.24 (0.17), 0.21 (0.25), 0.05 (0.75), 0.15 (0.41), 0.27 (0.13) at 1(st) month; 0.19 (0.28), 0.06 (0.71), −0.03 (0.85), 0.005 (0.97), 0.05 (0.78), 0.07 (0.68) at 3(rd) month. CONCLUSION: Postoperatively significant angle narrowing was noted. There was a negative correlation between IOP and preoperative ACD. There was no significant correlation between IOP and ICL vault with postoperative AS-OCT angle parameters. Wolters Kluwer - Medknow 2020-07 2020-06-25 /pmc/articles/PMC7574076/ /pubmed/32587181 http://dx.doi.org/10.4103/ijo.IJO_1540_19 Text en Copyright: © 2020 Indian Journal of Ophthalmology http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Singh, Rashmi
Vanathi, Murugesan
Kishore, Alisha
Tandon, Radhika
Singh, Divya
An anterior segment optical coherence tomography study of the anterior chamber angle after implantable collamer lens-V4c implantation in Asian Indian Eyes
title An anterior segment optical coherence tomography study of the anterior chamber angle after implantable collamer lens-V4c implantation in Asian Indian Eyes
title_full An anterior segment optical coherence tomography study of the anterior chamber angle after implantable collamer lens-V4c implantation in Asian Indian Eyes
title_fullStr An anterior segment optical coherence tomography study of the anterior chamber angle after implantable collamer lens-V4c implantation in Asian Indian Eyes
title_full_unstemmed An anterior segment optical coherence tomography study of the anterior chamber angle after implantable collamer lens-V4c implantation in Asian Indian Eyes
title_short An anterior segment optical coherence tomography study of the anterior chamber angle after implantable collamer lens-V4c implantation in Asian Indian Eyes
title_sort anterior segment optical coherence tomography study of the anterior chamber angle after implantable collamer lens-v4c implantation in asian indian eyes
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7574076/
https://www.ncbi.nlm.nih.gov/pubmed/32587181
http://dx.doi.org/10.4103/ijo.IJO_1540_19
work_keys_str_mv AT singhrashmi ananteriorsegmentopticalcoherencetomographystudyoftheanteriorchamberangleafterimplantablecollamerlensv4cimplantationinasianindianeyes
AT vanathimurugesan ananteriorsegmentopticalcoherencetomographystudyoftheanteriorchamberangleafterimplantablecollamerlensv4cimplantationinasianindianeyes
AT kishorealisha ananteriorsegmentopticalcoherencetomographystudyoftheanteriorchamberangleafterimplantablecollamerlensv4cimplantationinasianindianeyes
AT tandonradhika ananteriorsegmentopticalcoherencetomographystudyoftheanteriorchamberangleafterimplantablecollamerlensv4cimplantationinasianindianeyes
AT singhdivya ananteriorsegmentopticalcoherencetomographystudyoftheanteriorchamberangleafterimplantablecollamerlensv4cimplantationinasianindianeyes
AT singhrashmi anteriorsegmentopticalcoherencetomographystudyoftheanteriorchamberangleafterimplantablecollamerlensv4cimplantationinasianindianeyes
AT vanathimurugesan anteriorsegmentopticalcoherencetomographystudyoftheanteriorchamberangleafterimplantablecollamerlensv4cimplantationinasianindianeyes
AT kishorealisha anteriorsegmentopticalcoherencetomographystudyoftheanteriorchamberangleafterimplantablecollamerlensv4cimplantationinasianindianeyes
AT tandonradhika anteriorsegmentopticalcoherencetomographystudyoftheanteriorchamberangleafterimplantablecollamerlensv4cimplantationinasianindianeyes
AT singhdivya anteriorsegmentopticalcoherencetomographystudyoftheanteriorchamberangleafterimplantablecollamerlensv4cimplantationinasianindianeyes