Development of a Comprehensive, Contour-Based, Peer Review Workflow at a Community Proton Center
PURPOSE: Quality assurance and continuing quality improvement are integral parts of any radiation oncology practice. With increasingly conformal radiation treatments, it has become critical to focus on every slice of the target contour to ensure adequate tumor coverage and optimal normal tissue spar...