Cargando…
Small eye movements cannot be reliably measured by video-based P-CR eye-trackers
For evaluating whether an eye-tracker is suitable for measuring microsaccades, Poletti & Rucci (2016) propose that a measure called ‘resolution’ could be better than the more established root-mean-square of the sample-to-sample distances (RMS-S2S). Many open questions exist around the resolution...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer US
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7575492/ https://www.ncbi.nlm.nih.gov/pubmed/32206998 http://dx.doi.org/10.3758/s13428-020-01363-x |
_version_ | 1783597820908929024 |
---|---|
author | Holmqvist, Kenneth Blignaut, Pieter |
author_facet | Holmqvist, Kenneth Blignaut, Pieter |
author_sort | Holmqvist, Kenneth |
collection | PubMed |
description | For evaluating whether an eye-tracker is suitable for measuring microsaccades, Poletti & Rucci (2016) propose that a measure called ‘resolution’ could be better than the more established root-mean-square of the sample-to-sample distances (RMS-S2S). Many open questions exist around the resolution measure, however. Resolution needs to be calculated using data from an artificial eye that can be turned in very small steps. Furthermore, resolution has an unclear and uninvestigated relationship to the RMS-S2S and STD (standard deviation) measures of precision (Holmqvist & Andersson, 2017, p. 159-190), and there is another metric by the same name (Clarke, Ditterich, Drüen, Schönfeld, and Steineke 2002), which instead quantifies the errors of amplitude measurements. In this paper, we present a mechanism, the Stepperbox, for rotating artificial eyes in arbitrary angles from 1(′) (arcmin) and upward. We then use the Stepperbox to find the minimum reliably detectable rotations in 11 video-based eye-trackers (VOGs) and the Dual Purkinje Imaging (DPI) tracker. We find that resolution correlates significantly with RMS-S2S and, to a lesser extent, with STD. In addition, we find that although most eye-trackers can detect some small rotations of an artificial eye, the rotations of amplitudes up to 2(∘) are frequently erroneously measured by video-based eye-trackers. We show evidence that the corneal reflection (CR) feature of these eye-trackers is a major cause of erroneous measurements of small rotations of artificial eyes. Our data strengthen the existing body of evidence that video-based eye-trackers produce errors that may require that we reconsider some results from research on reading, microsaccades, and vergence, where the amplitude of small eye movements have been measured with past or current video-based eye-trackers. In contrast, the DPI reports correct rotation amplitudes down to 1(′). |
format | Online Article Text |
id | pubmed-7575492 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Springer US |
record_format | MEDLINE/PubMed |
spelling | pubmed-75754922020-10-21 Small eye movements cannot be reliably measured by video-based P-CR eye-trackers Holmqvist, Kenneth Blignaut, Pieter Behav Res Methods Article For evaluating whether an eye-tracker is suitable for measuring microsaccades, Poletti & Rucci (2016) propose that a measure called ‘resolution’ could be better than the more established root-mean-square of the sample-to-sample distances (RMS-S2S). Many open questions exist around the resolution measure, however. Resolution needs to be calculated using data from an artificial eye that can be turned in very small steps. Furthermore, resolution has an unclear and uninvestigated relationship to the RMS-S2S and STD (standard deviation) measures of precision (Holmqvist & Andersson, 2017, p. 159-190), and there is another metric by the same name (Clarke, Ditterich, Drüen, Schönfeld, and Steineke 2002), which instead quantifies the errors of amplitude measurements. In this paper, we present a mechanism, the Stepperbox, for rotating artificial eyes in arbitrary angles from 1(′) (arcmin) and upward. We then use the Stepperbox to find the minimum reliably detectable rotations in 11 video-based eye-trackers (VOGs) and the Dual Purkinje Imaging (DPI) tracker. We find that resolution correlates significantly with RMS-S2S and, to a lesser extent, with STD. In addition, we find that although most eye-trackers can detect some small rotations of an artificial eye, the rotations of amplitudes up to 2(∘) are frequently erroneously measured by video-based eye-trackers. We show evidence that the corneal reflection (CR) feature of these eye-trackers is a major cause of erroneous measurements of small rotations of artificial eyes. Our data strengthen the existing body of evidence that video-based eye-trackers produce errors that may require that we reconsider some results from research on reading, microsaccades, and vergence, where the amplitude of small eye movements have been measured with past or current video-based eye-trackers. In contrast, the DPI reports correct rotation amplitudes down to 1(′). Springer US 2020-03-23 2020 /pmc/articles/PMC7575492/ /pubmed/32206998 http://dx.doi.org/10.3758/s13428-020-01363-x Text en © The Author(s) 2020 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Article Holmqvist, Kenneth Blignaut, Pieter Small eye movements cannot be reliably measured by video-based P-CR eye-trackers |
title | Small eye movements cannot be reliably measured by video-based P-CR eye-trackers |
title_full | Small eye movements cannot be reliably measured by video-based P-CR eye-trackers |
title_fullStr | Small eye movements cannot be reliably measured by video-based P-CR eye-trackers |
title_full_unstemmed | Small eye movements cannot be reliably measured by video-based P-CR eye-trackers |
title_short | Small eye movements cannot be reliably measured by video-based P-CR eye-trackers |
title_sort | small eye movements cannot be reliably measured by video-based p-cr eye-trackers |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7575492/ https://www.ncbi.nlm.nih.gov/pubmed/32206998 http://dx.doi.org/10.3758/s13428-020-01363-x |
work_keys_str_mv | AT holmqvistkenneth smalleyemovementscannotbereliablymeasuredbyvideobasedpcreyetrackers AT blignautpieter smalleyemovementscannotbereliablymeasuredbyvideobasedpcreyetrackers |