Cargando…

A comparison of the delivery of inhaled drugs by jet nebulizer and vibrating mesh nebulizer using dual-source dual-energy computed tomography in rabbits: a preliminary in vivo study

BACKGROUND: Radionuclide imaging is the primary method of visually evaluating drug deposition in the lungs. Here, we used a new imaging technique, dual-source dual-energy computed tomography (DSDECT), to compare the ability of two nebulizers commonly used in clinical practice to deposit drugs in the...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Qixing, Liu, Yuhao, Zhu, Zhengfang, Hu, Jian, Li, Li, Wang, Sheng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: AME Publishing Company 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7575981/
https://www.ncbi.nlm.nih.gov/pubmed/33145291
http://dx.doi.org/10.21037/atm-20-1584
_version_ 1783597919392235520
author Wang, Qixing
Liu, Yuhao
Zhu, Zhengfang
Hu, Jian
Li, Li
Wang, Sheng
author_facet Wang, Qixing
Liu, Yuhao
Zhu, Zhengfang
Hu, Jian
Li, Li
Wang, Sheng
author_sort Wang, Qixing
collection PubMed
description BACKGROUND: Radionuclide imaging is the primary method of visually evaluating drug deposition in the lungs. Here, we used a new imaging technique, dual-source dual-energy computed tomography (DSDECT), to compare the ability of two nebulizers commonly used in clinical practice to deposit drugs in the lungs. METHODS: Male New Zealand White rabbits were randomly divided into a vibrating mesh nebulizer group and a small volume jet nebulizer group. First, two rabbits received methylene blue-iohexol-normal saline by inhalation to confirm that DSDECT was a feasible method of assessing aerosol inhalation. Then, 10 rabbits were subjected to DSDECT scan before and after receiving a iohexol-normal saline mixture by inhalation. All images were transferred and reconstructed on a workstation computer equipped with dedicated software. RESULTS: DSDECT revealed the same iodine distribution as tracheobronchial methylene blue staining on dissection. Significant differences between the groups in average CT value and iodine concentration were noted in the right upper lobe (P<0.05), but no other lobes showed statistically significant differences. The regional distribution of drugs in different lobes of the lung varied by nebulizer. CONCLUSIONS: DSDECT is a useful method of evaluating drug deposition in the lungs, and vibrating mesh nebulizers deposit more drugs than small volume jet nebulizers.
format Online
Article
Text
id pubmed-7575981
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher AME Publishing Company
record_format MEDLINE/PubMed
spelling pubmed-75759812020-11-02 A comparison of the delivery of inhaled drugs by jet nebulizer and vibrating mesh nebulizer using dual-source dual-energy computed tomography in rabbits: a preliminary in vivo study Wang, Qixing Liu, Yuhao Zhu, Zhengfang Hu, Jian Li, Li Wang, Sheng Ann Transl Med Original Article BACKGROUND: Radionuclide imaging is the primary method of visually evaluating drug deposition in the lungs. Here, we used a new imaging technique, dual-source dual-energy computed tomography (DSDECT), to compare the ability of two nebulizers commonly used in clinical practice to deposit drugs in the lungs. METHODS: Male New Zealand White rabbits were randomly divided into a vibrating mesh nebulizer group and a small volume jet nebulizer group. First, two rabbits received methylene blue-iohexol-normal saline by inhalation to confirm that DSDECT was a feasible method of assessing aerosol inhalation. Then, 10 rabbits were subjected to DSDECT scan before and after receiving a iohexol-normal saline mixture by inhalation. All images were transferred and reconstructed on a workstation computer equipped with dedicated software. RESULTS: DSDECT revealed the same iodine distribution as tracheobronchial methylene blue staining on dissection. Significant differences between the groups in average CT value and iodine concentration were noted in the right upper lobe (P<0.05), but no other lobes showed statistically significant differences. The regional distribution of drugs in different lobes of the lung varied by nebulizer. CONCLUSIONS: DSDECT is a useful method of evaluating drug deposition in the lungs, and vibrating mesh nebulizers deposit more drugs than small volume jet nebulizers. AME Publishing Company 2020-09 /pmc/articles/PMC7575981/ /pubmed/33145291 http://dx.doi.org/10.21037/atm-20-1584 Text en 2020 Annals of Translational Medicine. All rights reserved. https://creativecommons.org/licenses/by-nc-nd/4.0/Open Access Statement: This is an Open Access article distributed in accordance with the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 International License (CC BY-NC-ND 4.0), which permits the non-commercial replication and distribution of the article with the strict proviso that no changes or edits are made and the original work is properly cited (including links to both the formal publication through the relevant DOI and the license). See: https://creativecommons.org/licenses/by-nc-nd/4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) .
spellingShingle Original Article
Wang, Qixing
Liu, Yuhao
Zhu, Zhengfang
Hu, Jian
Li, Li
Wang, Sheng
A comparison of the delivery of inhaled drugs by jet nebulizer and vibrating mesh nebulizer using dual-source dual-energy computed tomography in rabbits: a preliminary in vivo study
title A comparison of the delivery of inhaled drugs by jet nebulizer and vibrating mesh nebulizer using dual-source dual-energy computed tomography in rabbits: a preliminary in vivo study
title_full A comparison of the delivery of inhaled drugs by jet nebulizer and vibrating mesh nebulizer using dual-source dual-energy computed tomography in rabbits: a preliminary in vivo study
title_fullStr A comparison of the delivery of inhaled drugs by jet nebulizer and vibrating mesh nebulizer using dual-source dual-energy computed tomography in rabbits: a preliminary in vivo study
title_full_unstemmed A comparison of the delivery of inhaled drugs by jet nebulizer and vibrating mesh nebulizer using dual-source dual-energy computed tomography in rabbits: a preliminary in vivo study
title_short A comparison of the delivery of inhaled drugs by jet nebulizer and vibrating mesh nebulizer using dual-source dual-energy computed tomography in rabbits: a preliminary in vivo study
title_sort comparison of the delivery of inhaled drugs by jet nebulizer and vibrating mesh nebulizer using dual-source dual-energy computed tomography in rabbits: a preliminary in vivo study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7575981/
https://www.ncbi.nlm.nih.gov/pubmed/33145291
http://dx.doi.org/10.21037/atm-20-1584
work_keys_str_mv AT wangqixing acomparisonofthedeliveryofinhaleddrugsbyjetnebulizerandvibratingmeshnebulizerusingdualsourcedualenergycomputedtomographyinrabbitsapreliminaryinvivostudy
AT liuyuhao acomparisonofthedeliveryofinhaleddrugsbyjetnebulizerandvibratingmeshnebulizerusingdualsourcedualenergycomputedtomographyinrabbitsapreliminaryinvivostudy
AT zhuzhengfang acomparisonofthedeliveryofinhaleddrugsbyjetnebulizerandvibratingmeshnebulizerusingdualsourcedualenergycomputedtomographyinrabbitsapreliminaryinvivostudy
AT hujian acomparisonofthedeliveryofinhaleddrugsbyjetnebulizerandvibratingmeshnebulizerusingdualsourcedualenergycomputedtomographyinrabbitsapreliminaryinvivostudy
AT lili acomparisonofthedeliveryofinhaleddrugsbyjetnebulizerandvibratingmeshnebulizerusingdualsourcedualenergycomputedtomographyinrabbitsapreliminaryinvivostudy
AT wangsheng acomparisonofthedeliveryofinhaleddrugsbyjetnebulizerandvibratingmeshnebulizerusingdualsourcedualenergycomputedtomographyinrabbitsapreliminaryinvivostudy
AT wangqixing comparisonofthedeliveryofinhaleddrugsbyjetnebulizerandvibratingmeshnebulizerusingdualsourcedualenergycomputedtomographyinrabbitsapreliminaryinvivostudy
AT liuyuhao comparisonofthedeliveryofinhaleddrugsbyjetnebulizerandvibratingmeshnebulizerusingdualsourcedualenergycomputedtomographyinrabbitsapreliminaryinvivostudy
AT zhuzhengfang comparisonofthedeliveryofinhaleddrugsbyjetnebulizerandvibratingmeshnebulizerusingdualsourcedualenergycomputedtomographyinrabbitsapreliminaryinvivostudy
AT hujian comparisonofthedeliveryofinhaleddrugsbyjetnebulizerandvibratingmeshnebulizerusingdualsourcedualenergycomputedtomographyinrabbitsapreliminaryinvivostudy
AT lili comparisonofthedeliveryofinhaleddrugsbyjetnebulizerandvibratingmeshnebulizerusingdualsourcedualenergycomputedtomographyinrabbitsapreliminaryinvivostudy
AT wangsheng comparisonofthedeliveryofinhaleddrugsbyjetnebulizerandvibratingmeshnebulizerusingdualsourcedualenergycomputedtomographyinrabbitsapreliminaryinvivostudy