Cargando…
Screening of serum protein biomarkers in hemorrhagic cerebral infarction by surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI-TOF-MS) technology
BACKGROUND: Serum samples of patients with hemorrhagic cerebral infarction (HCI), cerebral infarction (CI), and healthy controls (HCs) were used to screen statistically different protein peaks as potential biomarkers and to establish a decision tree classification model. METHODS: The serum samples f...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
AME Publishing Company
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7576047/ https://www.ncbi.nlm.nih.gov/pubmed/33241035 http://dx.doi.org/10.21037/atm-20-6071 |
_version_ | 1783597934902771712 |
---|---|
author | Han, Zongqiang Wen, Lina Feng, Linlin |
author_facet | Han, Zongqiang Wen, Lina Feng, Linlin |
author_sort | Han, Zongqiang |
collection | PubMed |
description | BACKGROUND: Serum samples of patients with hemorrhagic cerebral infarction (HCI), cerebral infarction (CI), and healthy controls (HCs) were used to screen statistically different protein peaks as potential biomarkers and to establish a decision tree classification model. METHODS: The serum samples from clinically confirmed patients with HCI and CI from November 2018 to October 2019 were collected, along with those of HCs who visited our hospital during the same period. Surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI-TOF-MS) with CM10 ProteinChip was used to analyze the differences in serum protein expression profiles of 30 patients with HCI, 32 patients with CI, and 31 HCs in the training group, and a decision tree classification model was established. At the same time, the blind test group (18 patients with HCI, 21 patients with CI, and 17 HCs) was tested by a blind method. RESULTS: Model 1 was successfully established by software analysis with a mass-to-charge ratio of 3,495.2, 8,941.0, and 15,890.4 as a differential protein peak. The sensitivity, specificity, and accuracy of model 1 in distinguishing HCI from HCs were 86.8%, 87.1%, and 86.9%, respectively. After verification of model 1 by the blind test group, the results showed that the sensitivity, specificity, and accuracy were 88.9%, 94.1%, and 91.4%, respectively. The sensitivity, specificity, and accuracy of model 2 with a mass-to-charge ratio of 2,941.3 as a differential protein peak were 86.7%, 75.0%, and 80.6%, respectively. After verification of model 2 by the blind test group, the results showed that the sensitivity, specificity, and accuracy were 83.3%, 90.4%, and 87.2%, respectively. CONCLUSIONS: Surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI-TOF-MS) and CM10 ProteinChip can be used to screen serum protein markers in patients with HCI. Mass-to-charge ratio of 3,495.2, 8,941.0, 15,890.4, and 2,941.3 may be potential protein biomarkers of HCI and used to distinguish HCI patients from HCs and CI. |
format | Online Article Text |
id | pubmed-7576047 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | AME Publishing Company |
record_format | MEDLINE/PubMed |
spelling | pubmed-75760472020-11-24 Screening of serum protein biomarkers in hemorrhagic cerebral infarction by surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI-TOF-MS) technology Han, Zongqiang Wen, Lina Feng, Linlin Ann Transl Med Original Article BACKGROUND: Serum samples of patients with hemorrhagic cerebral infarction (HCI), cerebral infarction (CI), and healthy controls (HCs) were used to screen statistically different protein peaks as potential biomarkers and to establish a decision tree classification model. METHODS: The serum samples from clinically confirmed patients with HCI and CI from November 2018 to October 2019 were collected, along with those of HCs who visited our hospital during the same period. Surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI-TOF-MS) with CM10 ProteinChip was used to analyze the differences in serum protein expression profiles of 30 patients with HCI, 32 patients with CI, and 31 HCs in the training group, and a decision tree classification model was established. At the same time, the blind test group (18 patients with HCI, 21 patients with CI, and 17 HCs) was tested by a blind method. RESULTS: Model 1 was successfully established by software analysis with a mass-to-charge ratio of 3,495.2, 8,941.0, and 15,890.4 as a differential protein peak. The sensitivity, specificity, and accuracy of model 1 in distinguishing HCI from HCs were 86.8%, 87.1%, and 86.9%, respectively. After verification of model 1 by the blind test group, the results showed that the sensitivity, specificity, and accuracy were 88.9%, 94.1%, and 91.4%, respectively. The sensitivity, specificity, and accuracy of model 2 with a mass-to-charge ratio of 2,941.3 as a differential protein peak were 86.7%, 75.0%, and 80.6%, respectively. After verification of model 2 by the blind test group, the results showed that the sensitivity, specificity, and accuracy were 83.3%, 90.4%, and 87.2%, respectively. CONCLUSIONS: Surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI-TOF-MS) and CM10 ProteinChip can be used to screen serum protein markers in patients with HCI. Mass-to-charge ratio of 3,495.2, 8,941.0, 15,890.4, and 2,941.3 may be potential protein biomarkers of HCI and used to distinguish HCI patients from HCs and CI. AME Publishing Company 2020-09 /pmc/articles/PMC7576047/ /pubmed/33241035 http://dx.doi.org/10.21037/atm-20-6071 Text en 2020 Annals of Translational Medicine. All rights reserved. https://creativecommons.org/licenses/by-nc-nd/4.0/Open Access Statement: This is an Open Access article distributed in accordance with the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 International License (CC BY-NC-ND 4.0), which permits the non-commercial replication and distribution of the article with the strict proviso that no changes or edits are made and the original work is properly cited (including links to both the formal publication through the relevant DOI and the license). See: https://creativecommons.org/licenses/by-nc-nd/4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) . |
spellingShingle | Original Article Han, Zongqiang Wen, Lina Feng, Linlin Screening of serum protein biomarkers in hemorrhagic cerebral infarction by surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI-TOF-MS) technology |
title | Screening of serum protein biomarkers in hemorrhagic cerebral infarction by surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI-TOF-MS) technology |
title_full | Screening of serum protein biomarkers in hemorrhagic cerebral infarction by surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI-TOF-MS) technology |
title_fullStr | Screening of serum protein biomarkers in hemorrhagic cerebral infarction by surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI-TOF-MS) technology |
title_full_unstemmed | Screening of serum protein biomarkers in hemorrhagic cerebral infarction by surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI-TOF-MS) technology |
title_short | Screening of serum protein biomarkers in hemorrhagic cerebral infarction by surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI-TOF-MS) technology |
title_sort | screening of serum protein biomarkers in hemorrhagic cerebral infarction by surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (seldi-tof-ms) technology |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7576047/ https://www.ncbi.nlm.nih.gov/pubmed/33241035 http://dx.doi.org/10.21037/atm-20-6071 |
work_keys_str_mv | AT hanzongqiang screeningofserumproteinbiomarkersinhemorrhagiccerebralinfarctionbysurfaceenhancedlaserdesorptionionizationtimeofflightmassspectrometryselditofmstechnology AT wenlina screeningofserumproteinbiomarkersinhemorrhagiccerebralinfarctionbysurfaceenhancedlaserdesorptionionizationtimeofflightmassspectrometryselditofmstechnology AT fenglinlin screeningofserumproteinbiomarkersinhemorrhagiccerebralinfarctionbysurfaceenhancedlaserdesorptionionizationtimeofflightmassspectrometryselditofmstechnology |