Cargando…

Screening of serum protein biomarkers in hemorrhagic cerebral infarction by surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI-TOF-MS) technology

BACKGROUND: Serum samples of patients with hemorrhagic cerebral infarction (HCI), cerebral infarction (CI), and healthy controls (HCs) were used to screen statistically different protein peaks as potential biomarkers and to establish a decision tree classification model. METHODS: The serum samples f...

Descripción completa

Detalles Bibliográficos
Autores principales: Han, Zongqiang, Wen, Lina, Feng, Linlin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: AME Publishing Company 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7576047/
https://www.ncbi.nlm.nih.gov/pubmed/33241035
http://dx.doi.org/10.21037/atm-20-6071
_version_ 1783597934902771712
author Han, Zongqiang
Wen, Lina
Feng, Linlin
author_facet Han, Zongqiang
Wen, Lina
Feng, Linlin
author_sort Han, Zongqiang
collection PubMed
description BACKGROUND: Serum samples of patients with hemorrhagic cerebral infarction (HCI), cerebral infarction (CI), and healthy controls (HCs) were used to screen statistically different protein peaks as potential biomarkers and to establish a decision tree classification model. METHODS: The serum samples from clinically confirmed patients with HCI and CI from November 2018 to October 2019 were collected, along with those of HCs who visited our hospital during the same period. Surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI-TOF-MS) with CM10 ProteinChip was used to analyze the differences in serum protein expression profiles of 30 patients with HCI, 32 patients with CI, and 31 HCs in the training group, and a decision tree classification model was established. At the same time, the blind test group (18 patients with HCI, 21 patients with CI, and 17 HCs) was tested by a blind method. RESULTS: Model 1 was successfully established by software analysis with a mass-to-charge ratio of 3,495.2, 8,941.0, and 15,890.4 as a differential protein peak. The sensitivity, specificity, and accuracy of model 1 in distinguishing HCI from HCs were 86.8%, 87.1%, and 86.9%, respectively. After verification of model 1 by the blind test group, the results showed that the sensitivity, specificity, and accuracy were 88.9%, 94.1%, and 91.4%, respectively. The sensitivity, specificity, and accuracy of model 2 with a mass-to-charge ratio of 2,941.3 as a differential protein peak were 86.7%, 75.0%, and 80.6%, respectively. After verification of model 2 by the blind test group, the results showed that the sensitivity, specificity, and accuracy were 83.3%, 90.4%, and 87.2%, respectively. CONCLUSIONS: Surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI-TOF-MS) and CM10 ProteinChip can be used to screen serum protein markers in patients with HCI. Mass-to-charge ratio of 3,495.2, 8,941.0, 15,890.4, and 2,941.3 may be potential protein biomarkers of HCI and used to distinguish HCI patients from HCs and CI.
format Online
Article
Text
id pubmed-7576047
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher AME Publishing Company
record_format MEDLINE/PubMed
spelling pubmed-75760472020-11-24 Screening of serum protein biomarkers in hemorrhagic cerebral infarction by surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI-TOF-MS) technology Han, Zongqiang Wen, Lina Feng, Linlin Ann Transl Med Original Article BACKGROUND: Serum samples of patients with hemorrhagic cerebral infarction (HCI), cerebral infarction (CI), and healthy controls (HCs) were used to screen statistically different protein peaks as potential biomarkers and to establish a decision tree classification model. METHODS: The serum samples from clinically confirmed patients with HCI and CI from November 2018 to October 2019 were collected, along with those of HCs who visited our hospital during the same period. Surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI-TOF-MS) with CM10 ProteinChip was used to analyze the differences in serum protein expression profiles of 30 patients with HCI, 32 patients with CI, and 31 HCs in the training group, and a decision tree classification model was established. At the same time, the blind test group (18 patients with HCI, 21 patients with CI, and 17 HCs) was tested by a blind method. RESULTS: Model 1 was successfully established by software analysis with a mass-to-charge ratio of 3,495.2, 8,941.0, and 15,890.4 as a differential protein peak. The sensitivity, specificity, and accuracy of model 1 in distinguishing HCI from HCs were 86.8%, 87.1%, and 86.9%, respectively. After verification of model 1 by the blind test group, the results showed that the sensitivity, specificity, and accuracy were 88.9%, 94.1%, and 91.4%, respectively. The sensitivity, specificity, and accuracy of model 2 with a mass-to-charge ratio of 2,941.3 as a differential protein peak were 86.7%, 75.0%, and 80.6%, respectively. After verification of model 2 by the blind test group, the results showed that the sensitivity, specificity, and accuracy were 83.3%, 90.4%, and 87.2%, respectively. CONCLUSIONS: Surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI-TOF-MS) and CM10 ProteinChip can be used to screen serum protein markers in patients with HCI. Mass-to-charge ratio of 3,495.2, 8,941.0, 15,890.4, and 2,941.3 may be potential protein biomarkers of HCI and used to distinguish HCI patients from HCs and CI. AME Publishing Company 2020-09 /pmc/articles/PMC7576047/ /pubmed/33241035 http://dx.doi.org/10.21037/atm-20-6071 Text en 2020 Annals of Translational Medicine. All rights reserved. https://creativecommons.org/licenses/by-nc-nd/4.0/Open Access Statement: This is an Open Access article distributed in accordance with the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 International License (CC BY-NC-ND 4.0), which permits the non-commercial replication and distribution of the article with the strict proviso that no changes or edits are made and the original work is properly cited (including links to both the formal publication through the relevant DOI and the license). See: https://creativecommons.org/licenses/by-nc-nd/4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) .
spellingShingle Original Article
Han, Zongqiang
Wen, Lina
Feng, Linlin
Screening of serum protein biomarkers in hemorrhagic cerebral infarction by surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI-TOF-MS) technology
title Screening of serum protein biomarkers in hemorrhagic cerebral infarction by surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI-TOF-MS) technology
title_full Screening of serum protein biomarkers in hemorrhagic cerebral infarction by surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI-TOF-MS) technology
title_fullStr Screening of serum protein biomarkers in hemorrhagic cerebral infarction by surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI-TOF-MS) technology
title_full_unstemmed Screening of serum protein biomarkers in hemorrhagic cerebral infarction by surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI-TOF-MS) technology
title_short Screening of serum protein biomarkers in hemorrhagic cerebral infarction by surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI-TOF-MS) technology
title_sort screening of serum protein biomarkers in hemorrhagic cerebral infarction by surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (seldi-tof-ms) technology
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7576047/
https://www.ncbi.nlm.nih.gov/pubmed/33241035
http://dx.doi.org/10.21037/atm-20-6071
work_keys_str_mv AT hanzongqiang screeningofserumproteinbiomarkersinhemorrhagiccerebralinfarctionbysurfaceenhancedlaserdesorptionionizationtimeofflightmassspectrometryselditofmstechnology
AT wenlina screeningofserumproteinbiomarkersinhemorrhagiccerebralinfarctionbysurfaceenhancedlaserdesorptionionizationtimeofflightmassspectrometryselditofmstechnology
AT fenglinlin screeningofserumproteinbiomarkersinhemorrhagiccerebralinfarctionbysurfaceenhancedlaserdesorptionionizationtimeofflightmassspectrometryselditofmstechnology