OBJECTIVES: As a step towards the comprehensive evaluation of movement in patients with low back pain, the aim of this study is to design a marker set (three rigid segment spine, pelvic and lower limb model) and evaluate the reliability and minimal detectable change (MDC) of this marker set in healt...

Descripción completa

Detalles Bibliográficos
Autores principales: Deane, J. A., Papi, E., Phillips, A. T. M., McGregor, A. H.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7579883/
https://www.ncbi.nlm.nih.gov/pubmed/33092633
http://dx.doi.org/10.1186/s13104-020-05295-9
_version_ 1783598683202256896
author Deane, J. A.
Papi, E.
Phillips, A. T. M.
McGregor, A. H.
author_facet Deane, J. A.
Papi, E.
Phillips, A. T. M.
McGregor, A. H.
author_sort Deane, J. A.
collection PubMed
description OBJECTIVES: As a step towards the comprehensive evaluation of movement in patients with low back pain, the aim of this study is to design a marker set (three rigid segment spine, pelvic and lower limb model) and evaluate the reliability and minimal detectable change (MDC) of this marker set in healthy adults during gait and sit to stand (STS) tasks using three dimensional motion capture. RESULTS: The ‘Imperial Spine’ marker set was used to assess relative peak angles during gait and STS tasks using the minimum recommended sample size (n = 10) for reliability studies with minimum Intraclass Correlation Coefficient (ICC) of 0.70, optimum ICC 0.90 and 9 trials replicated per subject per task. Intra- and inter-tester reliability between an experienced and inexperienced user was examined. ICC, mean, standard error (SEM), Bland Altman 95% limits of agreement (LOA) and MDC were computed. ICC values demonstrated excellent intra- and inter-tester reliability in both tasks, particularly in the sagittal plane (majority ICCs > 0.80). SEM measurements were lower in gait (0.8–5.5°) than STS tasks (1°-12.6°) as were MDC values. LOA demonstrated good agreement. The ‘Imperial Spine’ marker set is reliable for use in healthy adults during functional tasks. Future evaluation in patients is required.
format Online
Article
Text
id pubmed-7579883
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-75798832020-10-22 Reliability and minimal detectable change of the ‘Imperial Spine’ marker set for the evaluation of spinal and lower limb kinematics in adults Deane, J. A. Papi, E. Phillips, A. T. M. McGregor, A. H. BMC Res Notes Research Note OBJECTIVES: As a step towards the comprehensive evaluation of movement in patients with low back pain, the aim of this study is to design a marker set (three rigid segment spine, pelvic and lower limb model) and evaluate the reliability and minimal detectable change (MDC) of this marker set in healthy adults during gait and sit to stand (STS) tasks using three dimensional motion capture. RESULTS: The ‘Imperial Spine’ marker set was used to assess relative peak angles during gait and STS tasks using the minimum recommended sample size (n = 10) for reliability studies with minimum Intraclass Correlation Coefficient (ICC) of 0.70, optimum ICC 0.90 and 9 trials replicated per subject per task. Intra- and inter-tester reliability between an experienced and inexperienced user was examined. ICC, mean, standard error (SEM), Bland Altman 95% limits of agreement (LOA) and MDC were computed. ICC values demonstrated excellent intra- and inter-tester reliability in both tasks, particularly in the sagittal plane (majority ICCs > 0.80). SEM measurements were lower in gait (0.8–5.5°) than STS tasks (1°-12.6°) as were MDC values. LOA demonstrated good agreement. The ‘Imperial Spine’ marker set is reliable for use in healthy adults during functional tasks. Future evaluation in patients is required. BioMed Central 2020-10-22 /pmc/articles/PMC7579883/ /pubmed/33092633 http://dx.doi.org/10.1186/s13104-020-05295-9 Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research Note
Deane, J. A.
Papi, E.
Phillips, A. T. M.
McGregor, A. H.
Reliability and minimal detectable change of the ‘Imperial Spine’ marker set for the evaluation of spinal and lower limb kinematics in adults
title Reliability and minimal detectable change of the ‘Imperial Spine’ marker set for the evaluation of spinal and lower limb kinematics in adults
title_full Reliability and minimal detectable change of the ‘Imperial Spine’ marker set for the evaluation of spinal and lower limb kinematics in adults
title_fullStr Reliability and minimal detectable change of the ‘Imperial Spine’ marker set for the evaluation of spinal and lower limb kinematics in adults
title_full_unstemmed Reliability and minimal detectable change of the ‘Imperial Spine’ marker set for the evaluation of spinal and lower limb kinematics in adults
title_short Reliability and minimal detectable change of the ‘Imperial Spine’ marker set for the evaluation of spinal and lower limb kinematics in adults
title_sort reliability and minimal detectable change of the ‘imperial spine’ marker set for the evaluation of spinal and lower limb kinematics in adults
topic Research Note
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7579883/
https://www.ncbi.nlm.nih.gov/pubmed/33092633
http://dx.doi.org/10.1186/s13104-020-05295-9
work_keys_str_mv AT deaneja reliabilityandminimaldetectablechangeoftheimperialspinemarkersetfortheevaluationofspinalandlowerlimbkinematicsinadults
AT papie reliabilityandminimaldetectablechangeoftheimperialspinemarkersetfortheevaluationofspinalandlowerlimbkinematicsinadults
AT phillipsatm reliabilityandminimaldetectablechangeoftheimperialspinemarkersetfortheevaluationofspinalandlowerlimbkinematicsinadults
AT mcgregorah reliabilityandminimaldetectablechangeoftheimperialspinemarkersetfortheevaluationofspinalandlowerlimbkinematicsinadults