Cargando…
Method for Translation and Rotation Decoupling of Test Mass in Full-Maglev Vertical Superconducting Gravity Instruments
For full-maglev vertical superconducting gravity instruments, displacement control in the non-sensitive axis is a key technique to suppress cross-coupling noise in a dynamic environment. Motion decoupling of the test mass is crucial for the control design. In practice, when levitated, the test mass...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7582312/ https://www.ncbi.nlm.nih.gov/pubmed/32992482 http://dx.doi.org/10.3390/s20195527 |
_version_ | 1783599162112081920 |
---|---|
author | Wang, Lulu Chen, Daiyong Liu, Xikai Chen, Liang Liu, Xiangdong |
author_facet | Wang, Lulu Chen, Daiyong Liu, Xikai Chen, Liang Liu, Xiangdong |
author_sort | Wang, Lulu |
collection | PubMed |
description | For full-maglev vertical superconducting gravity instruments, displacement control in the non-sensitive axis is a key technique to suppress cross-coupling noise in a dynamic environment. Motion decoupling of the test mass is crucial for the control design. In practice, when levitated, the test mass is always in tilt, and unknown parameters will be introduced to the scale factors of displacement detection, which makes motion decoupling work extremely difficult. This paper proposes a method for decoupling the translation and rotation of the test mass in the non-sensitive axis for full-maglev vertical superconducting gravity instruments. In the method, superconducting circuits at low temperature and adjustable gain amplifiers at room temperature are combined to measure the difference between the scale factors caused by the tilt of the test mass. With the measured difference of the scale factors, the translation and rotation are decoupled according to the theoretical model. This method was verified with a test of a home-made full-maglev vertical superconducting accelerometer in which the translation and rotation were decoupled. |
format | Online Article Text |
id | pubmed-7582312 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-75823122020-10-28 Method for Translation and Rotation Decoupling of Test Mass in Full-Maglev Vertical Superconducting Gravity Instruments Wang, Lulu Chen, Daiyong Liu, Xikai Chen, Liang Liu, Xiangdong Sensors (Basel) Letter For full-maglev vertical superconducting gravity instruments, displacement control in the non-sensitive axis is a key technique to suppress cross-coupling noise in a dynamic environment. Motion decoupling of the test mass is crucial for the control design. In practice, when levitated, the test mass is always in tilt, and unknown parameters will be introduced to the scale factors of displacement detection, which makes motion decoupling work extremely difficult. This paper proposes a method for decoupling the translation and rotation of the test mass in the non-sensitive axis for full-maglev vertical superconducting gravity instruments. In the method, superconducting circuits at low temperature and adjustable gain amplifiers at room temperature are combined to measure the difference between the scale factors caused by the tilt of the test mass. With the measured difference of the scale factors, the translation and rotation are decoupled according to the theoretical model. This method was verified with a test of a home-made full-maglev vertical superconducting accelerometer in which the translation and rotation were decoupled. MDPI 2020-09-27 /pmc/articles/PMC7582312/ /pubmed/32992482 http://dx.doi.org/10.3390/s20195527 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Letter Wang, Lulu Chen, Daiyong Liu, Xikai Chen, Liang Liu, Xiangdong Method for Translation and Rotation Decoupling of Test Mass in Full-Maglev Vertical Superconducting Gravity Instruments |
title | Method for Translation and Rotation Decoupling of Test Mass in Full-Maglev Vertical Superconducting Gravity Instruments |
title_full | Method for Translation and Rotation Decoupling of Test Mass in Full-Maglev Vertical Superconducting Gravity Instruments |
title_fullStr | Method for Translation and Rotation Decoupling of Test Mass in Full-Maglev Vertical Superconducting Gravity Instruments |
title_full_unstemmed | Method for Translation and Rotation Decoupling of Test Mass in Full-Maglev Vertical Superconducting Gravity Instruments |
title_short | Method for Translation and Rotation Decoupling of Test Mass in Full-Maglev Vertical Superconducting Gravity Instruments |
title_sort | method for translation and rotation decoupling of test mass in full-maglev vertical superconducting gravity instruments |
topic | Letter |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7582312/ https://www.ncbi.nlm.nih.gov/pubmed/32992482 http://dx.doi.org/10.3390/s20195527 |
work_keys_str_mv | AT wanglulu methodfortranslationandrotationdecouplingoftestmassinfullmaglevverticalsuperconductinggravityinstruments AT chendaiyong methodfortranslationandrotationdecouplingoftestmassinfullmaglevverticalsuperconductinggravityinstruments AT liuxikai methodfortranslationandrotationdecouplingoftestmassinfullmaglevverticalsuperconductinggravityinstruments AT chenliang methodfortranslationandrotationdecouplingoftestmassinfullmaglevverticalsuperconductinggravityinstruments AT liuxiangdong methodfortranslationandrotationdecouplingoftestmassinfullmaglevverticalsuperconductinggravityinstruments |