Cargando…

Consistency and objectivity of automated embryo assessments using deep neural networks

OBJECTIVE: To evaluate the consistency and objectivity of deep neural networks in embryo scoring and making disposition decisions for biopsy and cryopreservation in comparison to grading by highly trained embryologists. DESIGN: Prospective double-blind study using retrospective data. SETTING: U.S.-b...

Descripción completa

Detalles Bibliográficos
Autores principales: Bormann, Charles L., Thirumalaraju, Prudhvi, Kanakasabapathy, Manoj Kumar, Kandula, Hemanth, Souter, Irene, Dimitriadis, Irene, Gupta, Raghav, Pooniwala, Rohan, Shafiee, Hadi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7583085/
https://www.ncbi.nlm.nih.gov/pubmed/32228880
http://dx.doi.org/10.1016/j.fertnstert.2019.12.004
_version_ 1783599339012096000
author Bormann, Charles L.
Thirumalaraju, Prudhvi
Kanakasabapathy, Manoj Kumar
Kandula, Hemanth
Souter, Irene
Dimitriadis, Irene
Gupta, Raghav
Pooniwala, Rohan
Shafiee, Hadi
author_facet Bormann, Charles L.
Thirumalaraju, Prudhvi
Kanakasabapathy, Manoj Kumar
Kandula, Hemanth
Souter, Irene
Dimitriadis, Irene
Gupta, Raghav
Pooniwala, Rohan
Shafiee, Hadi
author_sort Bormann, Charles L.
collection PubMed
description OBJECTIVE: To evaluate the consistency and objectivity of deep neural networks in embryo scoring and making disposition decisions for biopsy and cryopreservation in comparison to grading by highly trained embryologists. DESIGN: Prospective double-blind study using retrospective data. SETTING: U.S.-based large academic fertility center. PATIENTS: Not applicable. INTERVENTION(S): Embryo images (748 recorded at 70 hours postinsemination [hpi]) and 742 at 113 hpi) were used to evaluate embryologists and neural networks in embryo grading. The performance of 10 embryologists and a neural network were also evaluated in disposition decision making using 56 embryos. MAIN OUTCOME MEASURES: Coefficients of variation (%CV) and measures of consistencies were compared. RESULTS: Embryologists exhibited a high degree of variability (%CV averages: 82.84% for 70 hpi and 44.98% for 113 hpi) in grading embryo. When selecting blastocysts for biopsy or cryopreservation, embryologists had an average consistency of 52.14% and 57.68%, respectively. The neural network outperformed the embryologists in selecting blastocysts for biopsy and cryopreservation with a consistency of 83.92%. Cronbach’s α analysis revealed an α coefficient of 0.60 for the embryologists and 1.00 for the network. CONCLUSIONS: The results of our study show a high degree of interembryologist and intraembryologist variability in scoring embryos, likely due to the subjective nature of traditional morphology grading. This may ultimately lead to less precise disposition decisions and discarding of viable embryos. The application of a deep neural network, as shown in our study, can introduce improved reliability and high consistency during the process of embryo selection and disposition, potentially improving outcomes in an embryology laboratory.
format Online
Article
Text
id pubmed-7583085
institution National Center for Biotechnology Information
language English
publishDate 2020
record_format MEDLINE/PubMed
spelling pubmed-75830852020-10-23 Consistency and objectivity of automated embryo assessments using deep neural networks Bormann, Charles L. Thirumalaraju, Prudhvi Kanakasabapathy, Manoj Kumar Kandula, Hemanth Souter, Irene Dimitriadis, Irene Gupta, Raghav Pooniwala, Rohan Shafiee, Hadi Fertil Steril Article OBJECTIVE: To evaluate the consistency and objectivity of deep neural networks in embryo scoring and making disposition decisions for biopsy and cryopreservation in comparison to grading by highly trained embryologists. DESIGN: Prospective double-blind study using retrospective data. SETTING: U.S.-based large academic fertility center. PATIENTS: Not applicable. INTERVENTION(S): Embryo images (748 recorded at 70 hours postinsemination [hpi]) and 742 at 113 hpi) were used to evaluate embryologists and neural networks in embryo grading. The performance of 10 embryologists and a neural network were also evaluated in disposition decision making using 56 embryos. MAIN OUTCOME MEASURES: Coefficients of variation (%CV) and measures of consistencies were compared. RESULTS: Embryologists exhibited a high degree of variability (%CV averages: 82.84% for 70 hpi and 44.98% for 113 hpi) in grading embryo. When selecting blastocysts for biopsy or cryopreservation, embryologists had an average consistency of 52.14% and 57.68%, respectively. The neural network outperformed the embryologists in selecting blastocysts for biopsy and cryopreservation with a consistency of 83.92%. Cronbach’s α analysis revealed an α coefficient of 0.60 for the embryologists and 1.00 for the network. CONCLUSIONS: The results of our study show a high degree of interembryologist and intraembryologist variability in scoring embryos, likely due to the subjective nature of traditional morphology grading. This may ultimately lead to less precise disposition decisions and discarding of viable embryos. The application of a deep neural network, as shown in our study, can introduce improved reliability and high consistency during the process of embryo selection and disposition, potentially improving outcomes in an embryology laboratory. 2020-04 /pmc/articles/PMC7583085/ /pubmed/32228880 http://dx.doi.org/10.1016/j.fertnstert.2019.12.004 Text en This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).)
spellingShingle Article
Bormann, Charles L.
Thirumalaraju, Prudhvi
Kanakasabapathy, Manoj Kumar
Kandula, Hemanth
Souter, Irene
Dimitriadis, Irene
Gupta, Raghav
Pooniwala, Rohan
Shafiee, Hadi
Consistency and objectivity of automated embryo assessments using deep neural networks
title Consistency and objectivity of automated embryo assessments using deep neural networks
title_full Consistency and objectivity of automated embryo assessments using deep neural networks
title_fullStr Consistency and objectivity of automated embryo assessments using deep neural networks
title_full_unstemmed Consistency and objectivity of automated embryo assessments using deep neural networks
title_short Consistency and objectivity of automated embryo assessments using deep neural networks
title_sort consistency and objectivity of automated embryo assessments using deep neural networks
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7583085/
https://www.ncbi.nlm.nih.gov/pubmed/32228880
http://dx.doi.org/10.1016/j.fertnstert.2019.12.004
work_keys_str_mv AT bormanncharlesl consistencyandobjectivityofautomatedembryoassessmentsusingdeepneuralnetworks
AT thirumalarajuprudhvi consistencyandobjectivityofautomatedembryoassessmentsusingdeepneuralnetworks
AT kanakasabapathymanojkumar consistencyandobjectivityofautomatedembryoassessmentsusingdeepneuralnetworks
AT kandulahemanth consistencyandobjectivityofautomatedembryoassessmentsusingdeepneuralnetworks
AT souterirene consistencyandobjectivityofautomatedembryoassessmentsusingdeepneuralnetworks
AT dimitriadisirene consistencyandobjectivityofautomatedembryoassessmentsusingdeepneuralnetworks
AT guptaraghav consistencyandobjectivityofautomatedembryoassessmentsusingdeepneuralnetworks
AT pooniwalarohan consistencyandobjectivityofautomatedembryoassessmentsusingdeepneuralnetworks
AT shafieehadi consistencyandobjectivityofautomatedembryoassessmentsusingdeepneuralnetworks