Comparison of the mechanical properties of biodegradable and titanium osteosynthesis systems used in oral and maxillofacial surgery
To guide the selection of osteosynthesis systems, this study compared the mechanical properties of biodegradable and titanium osteosynthesis systems. SonicPins Rx and xG were subjected to pull-out tests. Additionally, 15 biodegradable (Inion CPS 2.0 and 2.5 mm; LactoSorb 2.0 mm; Macropore 2.0 mm; Po...
Autores principales: | Gareb, Barzi, Roossien, Charlotte C., van Bakelen, Nico B., Verkerke, Gijsbertus J., Vissink, Arjan, Bos, Ruud R. M., van Minnen, Baucke |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7584639/ https://www.ncbi.nlm.nih.gov/pubmed/33097757 http://dx.doi.org/10.1038/s41598-020-75299-9 |
Ejemplares similares
-
Titanium or Biodegradable Osteosynthesis in Maxillofacial Surgery? In Vitro and In Vivo Performances
por: Gareb, Barzi, et al.
Publicado: (2022) -
Reliability and accuracy of the torque applied to osteosynthesis screws by maxillofacial surgeons and residents
por: Gareb, Barzi, et al.
Publicado: (2022) -
Biocompatibility and degradation comparisons of four biodegradable copolymeric osteosynthesis systems used in maxillofacial surgery: A goat model with four years follow-up
por: Gareb, Barzi, et al.
Publicado: (2022) -
Efficacy and morbidity of biodegradable versus titanium osteosyntheses in orthognathic surgery: A systematic review with meta‐analysis and trial sequential analysis
por: Gareb, Barzi, et al.
Publicado: (2021) -
Comparison of the long-term clinical performance of a biodegradable and a titanium fixation system in maxillofacial surgery: A multicenter randomized controlled trial
por: Gareb, B., et al.
Publicado: (2017)