Cargando…
Effect of anticoagulant adjustment on prothrombin time test using two different PT reagents in patients with elevated hematocrit
The recommendations for adjustment of citrate volume in sample tubes with high hematocrit (Ht) are based on indirect studies of underfilled tubes or artificially constructed Ht values. The aim of this study was to evaluate the effect of citrate volume adjustment in sample tubes from patients with he...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7585133/ https://www.ncbi.nlm.nih.gov/pubmed/33134464 http://dx.doi.org/10.1016/j.plabm.2020.e00177 |
_version_ | 1783599721827270656 |
---|---|
author | Silva, Vanessa M. Rezende, Denise C. Garcia, Edna S. Cavalheiro, Cyrillo Strunz, Celia C. |
author_facet | Silva, Vanessa M. Rezende, Denise C. Garcia, Edna S. Cavalheiro, Cyrillo Strunz, Celia C. |
author_sort | Silva, Vanessa M. |
collection | PubMed |
description | The recommendations for adjustment of citrate volume in sample tubes with high hematocrit (Ht) are based on indirect studies of underfilled tubes or artificially constructed Ht values. The aim of this study was to evaluate the effect of citrate volume adjustment in sample tubes from patients with hematocrit >55% using two different prothrombin time (PT) tests. METHODS: Paired citrate-adjusted and unadjusted blood specimens were obtained from 181 patients from the pulmonary hypertension ambulatory with high Ht values and on warfarin therapy. The samples were tested using recombinant human tissue factor (RTF) and reagents extracted from rabbit brain (HS Plus). The results are expressed as the international normalized ratio (INR). The correlation and percent change (% change) between sample pairs were calculated. RESULTS: INR-RTF results from adjusted and unadjusted citrate blood specimens showed a strong correlation (R2 = 0.8226, p < 0.0001). The INR median was 2.25 (95% CI 2.10 to 2.41) for citrate-adjusted samples and was 2.22 (95% CI 2.06 to 2.38) for citrate-unadjusted samples. For samples with Ht >62%, the % change between sample pairs was >10%. Results using HS Plus showed a moderate correlation between citrate-adjusted and unadjusted samples (R2 = 0.4267, p < 0.0001). The INR median was 2.51 (95% CI 2.35 to 2.68) for citrate-adjusted samples and 3.45 (95% CI 3.11 to 3.80) for citrate-unadjusted samples. For samples with Ht>55%, the % change between sample pairs was higher than 10%. CONCLUSION: Our data demonstrate that in patients with polycythemia on warfarin therapy, INR-RTF does not require anticoagulant adjustment for assessment of samples with Ht <62%. |
format | Online Article Text |
id | pubmed-7585133 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-75851332020-10-30 Effect of anticoagulant adjustment on prothrombin time test using two different PT reagents in patients with elevated hematocrit Silva, Vanessa M. Rezende, Denise C. Garcia, Edna S. Cavalheiro, Cyrillo Strunz, Celia C. Pract Lab Med Article The recommendations for adjustment of citrate volume in sample tubes with high hematocrit (Ht) are based on indirect studies of underfilled tubes or artificially constructed Ht values. The aim of this study was to evaluate the effect of citrate volume adjustment in sample tubes from patients with hematocrit >55% using two different prothrombin time (PT) tests. METHODS: Paired citrate-adjusted and unadjusted blood specimens were obtained from 181 patients from the pulmonary hypertension ambulatory with high Ht values and on warfarin therapy. The samples were tested using recombinant human tissue factor (RTF) and reagents extracted from rabbit brain (HS Plus). The results are expressed as the international normalized ratio (INR). The correlation and percent change (% change) between sample pairs were calculated. RESULTS: INR-RTF results from adjusted and unadjusted citrate blood specimens showed a strong correlation (R2 = 0.8226, p < 0.0001). The INR median was 2.25 (95% CI 2.10 to 2.41) for citrate-adjusted samples and was 2.22 (95% CI 2.06 to 2.38) for citrate-unadjusted samples. For samples with Ht >62%, the % change between sample pairs was >10%. Results using HS Plus showed a moderate correlation between citrate-adjusted and unadjusted samples (R2 = 0.4267, p < 0.0001). The INR median was 2.51 (95% CI 2.35 to 2.68) for citrate-adjusted samples and 3.45 (95% CI 3.11 to 3.80) for citrate-unadjusted samples. For samples with Ht>55%, the % change between sample pairs was higher than 10%. CONCLUSION: Our data demonstrate that in patients with polycythemia on warfarin therapy, INR-RTF does not require anticoagulant adjustment for assessment of samples with Ht <62%. Elsevier 2020-10-17 /pmc/articles/PMC7585133/ /pubmed/33134464 http://dx.doi.org/10.1016/j.plabm.2020.e00177 Text en © 2020 The Author(s) http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Article Silva, Vanessa M. Rezende, Denise C. Garcia, Edna S. Cavalheiro, Cyrillo Strunz, Celia C. Effect of anticoagulant adjustment on prothrombin time test using two different PT reagents in patients with elevated hematocrit |
title | Effect of anticoagulant adjustment on prothrombin time test using two different PT reagents in patients with elevated hematocrit |
title_full | Effect of anticoagulant adjustment on prothrombin time test using two different PT reagents in patients with elevated hematocrit |
title_fullStr | Effect of anticoagulant adjustment on prothrombin time test using two different PT reagents in patients with elevated hematocrit |
title_full_unstemmed | Effect of anticoagulant adjustment on prothrombin time test using two different PT reagents in patients with elevated hematocrit |
title_short | Effect of anticoagulant adjustment on prothrombin time test using two different PT reagents in patients with elevated hematocrit |
title_sort | effect of anticoagulant adjustment on prothrombin time test using two different pt reagents in patients with elevated hematocrit |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7585133/ https://www.ncbi.nlm.nih.gov/pubmed/33134464 http://dx.doi.org/10.1016/j.plabm.2020.e00177 |
work_keys_str_mv | AT silvavanessam effectofanticoagulantadjustmentonprothrombintimetestusingtwodifferentptreagentsinpatientswithelevatedhematocrit AT rezendedenisec effectofanticoagulantadjustmentonprothrombintimetestusingtwodifferentptreagentsinpatientswithelevatedhematocrit AT garciaednas effectofanticoagulantadjustmentonprothrombintimetestusingtwodifferentptreagentsinpatientswithelevatedhematocrit AT cavalheirocyrillo effectofanticoagulantadjustmentonprothrombintimetestusingtwodifferentptreagentsinpatientswithelevatedhematocrit AT strunzceliac effectofanticoagulantadjustmentonprothrombintimetestusingtwodifferentptreagentsinpatientswithelevatedhematocrit |