Cargando…

Effect of anticoagulant adjustment on prothrombin time test using two different PT reagents in patients with elevated hematocrit

The recommendations for adjustment of citrate volume in sample tubes with high hematocrit (Ht) are based on indirect studies of underfilled tubes or artificially constructed Ht values. The aim of this study was to evaluate the effect of citrate volume adjustment in sample tubes from patients with he...

Descripción completa

Detalles Bibliográficos
Autores principales: Silva, Vanessa M., Rezende, Denise C., Garcia, Edna S., Cavalheiro, Cyrillo, Strunz, Celia C.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7585133/
https://www.ncbi.nlm.nih.gov/pubmed/33134464
http://dx.doi.org/10.1016/j.plabm.2020.e00177
_version_ 1783599721827270656
author Silva, Vanessa M.
Rezende, Denise C.
Garcia, Edna S.
Cavalheiro, Cyrillo
Strunz, Celia C.
author_facet Silva, Vanessa M.
Rezende, Denise C.
Garcia, Edna S.
Cavalheiro, Cyrillo
Strunz, Celia C.
author_sort Silva, Vanessa M.
collection PubMed
description The recommendations for adjustment of citrate volume in sample tubes with high hematocrit (Ht) are based on indirect studies of underfilled tubes or artificially constructed Ht values. The aim of this study was to evaluate the effect of citrate volume adjustment in sample tubes from patients with hematocrit >55% using two different prothrombin time (PT) tests. METHODS: Paired citrate-adjusted and unadjusted blood specimens were obtained from 181 patients from the pulmonary hypertension ambulatory with high Ht values and on warfarin therapy. The samples were tested using recombinant human tissue factor (RTF) and reagents extracted from rabbit brain (HS Plus). The results are expressed as the international normalized ratio (INR). The correlation and percent change (% change) between sample pairs were calculated. RESULTS: INR-RTF results from adjusted and unadjusted citrate blood specimens showed a strong correlation (R2 ​= ​0.8226, p ​< ​0.0001). The INR median was 2.25 (95% CI 2.10 to 2.41) for citrate-adjusted samples and was 2.22 (95% CI 2.06 to 2.38) for citrate-unadjusted samples. For samples with Ht >62%, the % change between sample pairs was >10%. Results using HS Plus showed a moderate correlation between citrate-adjusted and unadjusted samples (R2 ​= ​0.4267, p ​< ​0.0001). The INR median was 2.51 (95% CI 2.35 to 2.68) for citrate-adjusted samples and 3.45 (95% CI 3.11 to 3.80) for citrate-unadjusted samples. For samples with Ht>55%, the % change between sample pairs was higher than 10%. CONCLUSION: Our data demonstrate that in patients with polycythemia on warfarin therapy, INR-RTF does not require anticoagulant adjustment for assessment of samples with Ht <62%.
format Online
Article
Text
id pubmed-7585133
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-75851332020-10-30 Effect of anticoagulant adjustment on prothrombin time test using two different PT reagents in patients with elevated hematocrit Silva, Vanessa M. Rezende, Denise C. Garcia, Edna S. Cavalheiro, Cyrillo Strunz, Celia C. Pract Lab Med Article The recommendations for adjustment of citrate volume in sample tubes with high hematocrit (Ht) are based on indirect studies of underfilled tubes or artificially constructed Ht values. The aim of this study was to evaluate the effect of citrate volume adjustment in sample tubes from patients with hematocrit >55% using two different prothrombin time (PT) tests. METHODS: Paired citrate-adjusted and unadjusted blood specimens were obtained from 181 patients from the pulmonary hypertension ambulatory with high Ht values and on warfarin therapy. The samples were tested using recombinant human tissue factor (RTF) and reagents extracted from rabbit brain (HS Plus). The results are expressed as the international normalized ratio (INR). The correlation and percent change (% change) between sample pairs were calculated. RESULTS: INR-RTF results from adjusted and unadjusted citrate blood specimens showed a strong correlation (R2 ​= ​0.8226, p ​< ​0.0001). The INR median was 2.25 (95% CI 2.10 to 2.41) for citrate-adjusted samples and was 2.22 (95% CI 2.06 to 2.38) for citrate-unadjusted samples. For samples with Ht >62%, the % change between sample pairs was >10%. Results using HS Plus showed a moderate correlation between citrate-adjusted and unadjusted samples (R2 ​= ​0.4267, p ​< ​0.0001). The INR median was 2.51 (95% CI 2.35 to 2.68) for citrate-adjusted samples and 3.45 (95% CI 3.11 to 3.80) for citrate-unadjusted samples. For samples with Ht>55%, the % change between sample pairs was higher than 10%. CONCLUSION: Our data demonstrate that in patients with polycythemia on warfarin therapy, INR-RTF does not require anticoagulant adjustment for assessment of samples with Ht <62%. Elsevier 2020-10-17 /pmc/articles/PMC7585133/ /pubmed/33134464 http://dx.doi.org/10.1016/j.plabm.2020.e00177 Text en © 2020 The Author(s) http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Article
Silva, Vanessa M.
Rezende, Denise C.
Garcia, Edna S.
Cavalheiro, Cyrillo
Strunz, Celia C.
Effect of anticoagulant adjustment on prothrombin time test using two different PT reagents in patients with elevated hematocrit
title Effect of anticoagulant adjustment on prothrombin time test using two different PT reagents in patients with elevated hematocrit
title_full Effect of anticoagulant adjustment on prothrombin time test using two different PT reagents in patients with elevated hematocrit
title_fullStr Effect of anticoagulant adjustment on prothrombin time test using two different PT reagents in patients with elevated hematocrit
title_full_unstemmed Effect of anticoagulant adjustment on prothrombin time test using two different PT reagents in patients with elevated hematocrit
title_short Effect of anticoagulant adjustment on prothrombin time test using two different PT reagents in patients with elevated hematocrit
title_sort effect of anticoagulant adjustment on prothrombin time test using two different pt reagents in patients with elevated hematocrit
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7585133/
https://www.ncbi.nlm.nih.gov/pubmed/33134464
http://dx.doi.org/10.1016/j.plabm.2020.e00177
work_keys_str_mv AT silvavanessam effectofanticoagulantadjustmentonprothrombintimetestusingtwodifferentptreagentsinpatientswithelevatedhematocrit
AT rezendedenisec effectofanticoagulantadjustmentonprothrombintimetestusingtwodifferentptreagentsinpatientswithelevatedhematocrit
AT garciaednas effectofanticoagulantadjustmentonprothrombintimetestusingtwodifferentptreagentsinpatientswithelevatedhematocrit
AT cavalheirocyrillo effectofanticoagulantadjustmentonprothrombintimetestusingtwodifferentptreagentsinpatientswithelevatedhematocrit
AT strunzceliac effectofanticoagulantadjustmentonprothrombintimetestusingtwodifferentptreagentsinpatientswithelevatedhematocrit