Repeatability and Reproducibility of Axial and Lateral Measurements on Handheld Optical Coherence Tomography Systems Compared with Tabletop System
PURPOSE: To compare the repeatability and reproducibility of axial and lateral retinal measurements using handheld optical coherence tomography (OCT) systems and a tabletop OCT system. METHODS: Graders measured central foveal thickness (CFT), optic nerve-to-fovea distance (OFD), and retinal nerve fi...
Autores principales: | Chen, Xi, Tai, Vincent, McGeehan, Brendan, Ying, Gui-Shuang, Viehland, Christian, Imperio, Ryan, Winter, Katrina P., Raynor, William, Tran-Viet, Du, Mangalesh, Shwetha, Maguire, Maureen G., Toth, Cynthia A. |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Association for Research in Vision and Ophthalmology
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7585396/ https://www.ncbi.nlm.nih.gov/pubmed/33150050 http://dx.doi.org/10.1167/tvst.9.11.25 |
Ejemplares similares
-
Systemic Factors Associated with a Thinner Choroid in Preterm Infants
por: Michalak, Suzanne M., et al.
Publicado: (2021) -
4431 Utilization of swept source optical coherence tomography to optimize characterization of cystoid macular edema in preterm infants
por: Seely, Kai, et al.
Publicado: (2020) -
Depth-Resolved Visualization of Perifoveal Retinal Vasculature in Preterm Infants Using Handheld Optical Coherence Tomography Angiography
por: Patel, Pujan R., et al.
Publicado: (2021) -
70740 Impact of fundus pigmentation on retinal layer visibility on investigational bedside optical coherence tomography in preterm infants
por: Seely, Kai R., et al.
Publicado: (2021) -
Coherent Tabletop EUV Ptychography of Nanopatterns
por: Truong, Nguyen Xuan, et al.
Publicado: (2018)