Dynamic tracking of microvascular hemoglobin content for continuous perfusion monitoring in the intensive care unit: pilot feasibility study

Purpose: There is a need for bedside methods to monitor oxygen delivery in the microcirculation. Near-infrared spectroscopy commonly measures tissue oxygen saturation, but does not reflect the time-dependent variability of microvascular hemoglobin content (MHC) that attempts to match oxygen supply w...

Descripción completa

Detalles Bibliográficos
Autores principales: Mendelson, Asher A., Rajaram, Ajay, Bainbridge, Daniel, Lawrence, Keith St., Bentall, Tracey, Sharpe, Michael, Diop, Mamadou, Ellis, Christopher G.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Netherlands 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7586414/
https://www.ncbi.nlm.nih.gov/pubmed/33104968
http://dx.doi.org/10.1007/s10877-020-00611-x
_version_ 1783599992210980864
author Mendelson, Asher A.
Rajaram, Ajay
Bainbridge, Daniel
Lawrence, Keith St.
Bentall, Tracey
Sharpe, Michael
Diop, Mamadou
Ellis, Christopher G.
author_facet Mendelson, Asher A.
Rajaram, Ajay
Bainbridge, Daniel
Lawrence, Keith St.
Bentall, Tracey
Sharpe, Michael
Diop, Mamadou
Ellis, Christopher G.
author_sort Mendelson, Asher A.
collection PubMed
description Purpose: There is a need for bedside methods to monitor oxygen delivery in the microcirculation. Near-infrared spectroscopy commonly measures tissue oxygen saturation, but does not reflect the time-dependent variability of microvascular hemoglobin content (MHC) that attempts to match oxygen supply with demand. The objective of this study is to determine the feasibility of MHC monitoring in critically ill patients using high-resolution near-infrared spectroscopy to assess perfusion in the peripheral microcirculation. Methods: Prospective observational cohort of 36 patients admitted within 48 h at a tertiary intensive care unit. Perfusion was measured on the quadriceps, biceps, and/or deltoid, using the temporal change in optical density at the isosbestic wavelength of hemoglobin (798 nm). Continuous wavelet transform was applied to the hemoglobin signal to delineate frequency ranges corresponding to physiological oscillations in the cardiovascular system. Results: 31/36 patients had adequate signal quality for analysis, most commonly affected by motion artifacts. MHC signal demonstrates inter-subject heterogeneity in the cohort, indicated by different patterns of variability and frequency composition. Signal characteristics were concordant between muscle groups in the same patient, and correlated with systemic hemoglobin levels and oxygen saturation. Signal power was lower for patients receiving vasopressors, but not correlated with mean arterial pressure. Mechanical ventilation directly impacts MHC in peripheral tissue. Conclusion: MHC can be measured continuously in the ICU with high-resolution near-infrared spectroscopy, and reflects the dynamic variability of hemoglobin distribution in the microcirculation. Results suggest this novel hemodynamic metric should be further evaluated for diagnosing microvascular dysfunction and monitoring peripheral perfusion. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s10877-020-00611-x) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-7586414
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Springer Netherlands
record_format MEDLINE/PubMed
spelling pubmed-75864142020-10-26 Dynamic tracking of microvascular hemoglobin content for continuous perfusion monitoring in the intensive care unit: pilot feasibility study Mendelson, Asher A. Rajaram, Ajay Bainbridge, Daniel Lawrence, Keith St. Bentall, Tracey Sharpe, Michael Diop, Mamadou Ellis, Christopher G. J Clin Monit Comput Original Research Purpose: There is a need for bedside methods to monitor oxygen delivery in the microcirculation. Near-infrared spectroscopy commonly measures tissue oxygen saturation, but does not reflect the time-dependent variability of microvascular hemoglobin content (MHC) that attempts to match oxygen supply with demand. The objective of this study is to determine the feasibility of MHC monitoring in critically ill patients using high-resolution near-infrared spectroscopy to assess perfusion in the peripheral microcirculation. Methods: Prospective observational cohort of 36 patients admitted within 48 h at a tertiary intensive care unit. Perfusion was measured on the quadriceps, biceps, and/or deltoid, using the temporal change in optical density at the isosbestic wavelength of hemoglobin (798 nm). Continuous wavelet transform was applied to the hemoglobin signal to delineate frequency ranges corresponding to physiological oscillations in the cardiovascular system. Results: 31/36 patients had adequate signal quality for analysis, most commonly affected by motion artifacts. MHC signal demonstrates inter-subject heterogeneity in the cohort, indicated by different patterns of variability and frequency composition. Signal characteristics were concordant between muscle groups in the same patient, and correlated with systemic hemoglobin levels and oxygen saturation. Signal power was lower for patients receiving vasopressors, but not correlated with mean arterial pressure. Mechanical ventilation directly impacts MHC in peripheral tissue. Conclusion: MHC can be measured continuously in the ICU with high-resolution near-infrared spectroscopy, and reflects the dynamic variability of hemoglobin distribution in the microcirculation. Results suggest this novel hemodynamic metric should be further evaluated for diagnosing microvascular dysfunction and monitoring peripheral perfusion. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s10877-020-00611-x) contains supplementary material, which is available to authorized users. Springer Netherlands 2020-10-26 2021 /pmc/articles/PMC7586414/ /pubmed/33104968 http://dx.doi.org/10.1007/s10877-020-00611-x Text en © Springer Nature B.V. 2020 This article is made available via the PMC Open Access Subset for unrestricted research re-use and secondary analysis in any form or by any means with acknowledgement of the original source. These permissions are granted for the duration of the World Health Organization (WHO) declaration of COVID-19 as a global pandemic.
spellingShingle Original Research
Mendelson, Asher A.
Rajaram, Ajay
Bainbridge, Daniel
Lawrence, Keith St.
Bentall, Tracey
Sharpe, Michael
Diop, Mamadou
Ellis, Christopher G.
Dynamic tracking of microvascular hemoglobin content for continuous perfusion monitoring in the intensive care unit: pilot feasibility study
title Dynamic tracking of microvascular hemoglobin content for continuous perfusion monitoring in the intensive care unit: pilot feasibility study
title_full Dynamic tracking of microvascular hemoglobin content for continuous perfusion monitoring in the intensive care unit: pilot feasibility study
title_fullStr Dynamic tracking of microvascular hemoglobin content for continuous perfusion monitoring in the intensive care unit: pilot feasibility study
title_full_unstemmed Dynamic tracking of microvascular hemoglobin content for continuous perfusion monitoring in the intensive care unit: pilot feasibility study
title_short Dynamic tracking of microvascular hemoglobin content for continuous perfusion monitoring in the intensive care unit: pilot feasibility study
title_sort dynamic tracking of microvascular hemoglobin content for continuous perfusion monitoring in the intensive care unit: pilot feasibility study
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7586414/
https://www.ncbi.nlm.nih.gov/pubmed/33104968
http://dx.doi.org/10.1007/s10877-020-00611-x
work_keys_str_mv AT mendelsonashera dynamictrackingofmicrovascularhemoglobincontentforcontinuousperfusionmonitoringintheintensivecareunitpilotfeasibilitystudy
AT rajaramajay dynamictrackingofmicrovascularhemoglobincontentforcontinuousperfusionmonitoringintheintensivecareunitpilotfeasibilitystudy
AT bainbridgedaniel dynamictrackingofmicrovascularhemoglobincontentforcontinuousperfusionmonitoringintheintensivecareunitpilotfeasibilitystudy
AT lawrencekeithst dynamictrackingofmicrovascularhemoglobincontentforcontinuousperfusionmonitoringintheintensivecareunitpilotfeasibilitystudy
AT bentalltracey dynamictrackingofmicrovascularhemoglobincontentforcontinuousperfusionmonitoringintheintensivecareunitpilotfeasibilitystudy
AT sharpemichael dynamictrackingofmicrovascularhemoglobincontentforcontinuousperfusionmonitoringintheintensivecareunitpilotfeasibilitystudy
AT diopmamadou dynamictrackingofmicrovascularhemoglobincontentforcontinuousperfusionmonitoringintheintensivecareunitpilotfeasibilitystudy
AT ellischristopherg dynamictrackingofmicrovascularhemoglobincontentforcontinuousperfusionmonitoringintheintensivecareunitpilotfeasibilitystudy
AT dynamictrackingofmicrovascularhemoglobincontentforcontinuousperfusionmonitoringintheintensivecareunitpilotfeasibilitystudy