Measuring beta‐galactose exposure on platelets: Standardization and healthy reference values
BACKGROUND: Correct diagnosis of the cause of thrombocytopenia is crucial for the appropriate management of patients. Hyposialylation/desialylation (characterized by abnormally high β‐galactose exposure) accelerates platelet clearance and can lead to thrombocytopenia. However, the reference range fo...
Autores principales: | , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7586713/ https://www.ncbi.nlm.nih.gov/pubmed/33134771 http://dx.doi.org/10.1002/rth2.12369 |
_version_ | 1783600053532753920 |
---|---|
author | Lasne, Dominique Pascreau, Tiffany Darame, Sadyo Bourrienne, Marie‐Charlotte Tournoux, Peggy Philippe, Aurélien Ziachahabi, Sara Suarez, Felipe Marcais, Ambroise Dupont, Annabelle Denis, Cécile V. Kauskot, Alexandre Borgel, Delphine |
author_facet | Lasne, Dominique Pascreau, Tiffany Darame, Sadyo Bourrienne, Marie‐Charlotte Tournoux, Peggy Philippe, Aurélien Ziachahabi, Sara Suarez, Felipe Marcais, Ambroise Dupont, Annabelle Denis, Cécile V. Kauskot, Alexandre Borgel, Delphine |
author_sort | Lasne, Dominique |
collection | PubMed |
description | BACKGROUND: Correct diagnosis of the cause of thrombocytopenia is crucial for the appropriate management of patients. Hyposialylation/desialylation (characterized by abnormally high β‐galactose exposure) accelerates platelet clearance and can lead to thrombocytopenia. However, the reference range for β‐galactose exposure in healthy individuals has not been defined previously. OBJECTIVE: The objective of the present study was to develop a standardized assay of platelet β‐galactose exposure for implementation in a clinical laboratory. METHODS: β‐Galactose exposure was measured in platelet‐rich plasma by using flow cytometry and Ricinus communis agglutinin (RCA). A population of 120 healthy adults was recruited to study variability. RESULTS: We determined an optimal RCA concentration of 12.5 μg/mL. The measure was stable for up to 4 hours (mean fluorescence intensity [MFI]‐RCA: 1233 ± 329 at 0 hour and 1480 ± 410 at 4 hours). The platelet count did not induce a variation of RCA and the measure of RCA was stable when tested up to 24 hours after blood collection (MFI‐RCA: 1252 ± 434 at day 0 and 1140 ± 297 24 hours after blood sampling). To take into account the platelet size, results should be expressed as RCA/forward scatter ratio. We used the assay to study variability in 120 healthy adults, and we found that the ratio is independent of sex and blood group. CONCLUSION: We defined a normal range in a healthy population and several preanalytical and analytical variables were evaluated, together with positive and negative controls. This assay may assist in the diagnosis of thrombocytopenic diseases linked to changes in β‐galactose exposure. |
format | Online Article Text |
id | pubmed-7586713 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-75867132020-10-30 Measuring beta‐galactose exposure on platelets: Standardization and healthy reference values Lasne, Dominique Pascreau, Tiffany Darame, Sadyo Bourrienne, Marie‐Charlotte Tournoux, Peggy Philippe, Aurélien Ziachahabi, Sara Suarez, Felipe Marcais, Ambroise Dupont, Annabelle Denis, Cécile V. Kauskot, Alexandre Borgel, Delphine Res Pract Thromb Haemost Original Articles: Hemostasis BACKGROUND: Correct diagnosis of the cause of thrombocytopenia is crucial for the appropriate management of patients. Hyposialylation/desialylation (characterized by abnormally high β‐galactose exposure) accelerates platelet clearance and can lead to thrombocytopenia. However, the reference range for β‐galactose exposure in healthy individuals has not been defined previously. OBJECTIVE: The objective of the present study was to develop a standardized assay of platelet β‐galactose exposure for implementation in a clinical laboratory. METHODS: β‐Galactose exposure was measured in platelet‐rich plasma by using flow cytometry and Ricinus communis agglutinin (RCA). A population of 120 healthy adults was recruited to study variability. RESULTS: We determined an optimal RCA concentration of 12.5 μg/mL. The measure was stable for up to 4 hours (mean fluorescence intensity [MFI]‐RCA: 1233 ± 329 at 0 hour and 1480 ± 410 at 4 hours). The platelet count did not induce a variation of RCA and the measure of RCA was stable when tested up to 24 hours after blood collection (MFI‐RCA: 1252 ± 434 at day 0 and 1140 ± 297 24 hours after blood sampling). To take into account the platelet size, results should be expressed as RCA/forward scatter ratio. We used the assay to study variability in 120 healthy adults, and we found that the ratio is independent of sex and blood group. CONCLUSION: We defined a normal range in a healthy population and several preanalytical and analytical variables were evaluated, together with positive and negative controls. This assay may assist in the diagnosis of thrombocytopenic diseases linked to changes in β‐galactose exposure. John Wiley and Sons Inc. 2020-06-02 /pmc/articles/PMC7586713/ /pubmed/33134771 http://dx.doi.org/10.1002/rth2.12369 Text en © 2020 The Authors. Research and Practice in Thrombosis and Haemostasis published by Wiley Periodicals LLC on behalf of International Society on Thrombosis and Haemostasis This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made. |
spellingShingle | Original Articles: Hemostasis Lasne, Dominique Pascreau, Tiffany Darame, Sadyo Bourrienne, Marie‐Charlotte Tournoux, Peggy Philippe, Aurélien Ziachahabi, Sara Suarez, Felipe Marcais, Ambroise Dupont, Annabelle Denis, Cécile V. Kauskot, Alexandre Borgel, Delphine Measuring beta‐galactose exposure on platelets: Standardization and healthy reference values |
title | Measuring beta‐galactose exposure on platelets: Standardization and healthy reference values |
title_full | Measuring beta‐galactose exposure on platelets: Standardization and healthy reference values |
title_fullStr | Measuring beta‐galactose exposure on platelets: Standardization and healthy reference values |
title_full_unstemmed | Measuring beta‐galactose exposure on platelets: Standardization and healthy reference values |
title_short | Measuring beta‐galactose exposure on platelets: Standardization and healthy reference values |
title_sort | measuring beta‐galactose exposure on platelets: standardization and healthy reference values |
topic | Original Articles: Hemostasis |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7586713/ https://www.ncbi.nlm.nih.gov/pubmed/33134771 http://dx.doi.org/10.1002/rth2.12369 |
work_keys_str_mv | AT lasnedominique measuringbetagalactoseexposureonplateletsstandardizationandhealthyreferencevalues AT pascreautiffany measuringbetagalactoseexposureonplateletsstandardizationandhealthyreferencevalues AT daramesadyo measuringbetagalactoseexposureonplateletsstandardizationandhealthyreferencevalues AT bourriennemariecharlotte measuringbetagalactoseexposureonplateletsstandardizationandhealthyreferencevalues AT tournouxpeggy measuringbetagalactoseexposureonplateletsstandardizationandhealthyreferencevalues AT philippeaurelien measuringbetagalactoseexposureonplateletsstandardizationandhealthyreferencevalues AT ziachahabisara measuringbetagalactoseexposureonplateletsstandardizationandhealthyreferencevalues AT suarezfelipe measuringbetagalactoseexposureonplateletsstandardizationandhealthyreferencevalues AT marcaisambroise measuringbetagalactoseexposureonplateletsstandardizationandhealthyreferencevalues AT dupontannabelle measuringbetagalactoseexposureonplateletsstandardizationandhealthyreferencevalues AT deniscecilev measuringbetagalactoseexposureonplateletsstandardizationandhealthyreferencevalues AT kauskotalexandre measuringbetagalactoseexposureonplateletsstandardizationandhealthyreferencevalues AT borgeldelphine measuringbetagalactoseexposureonplateletsstandardizationandhealthyreferencevalues |