Cargando…

A comparison of the corneal biomechanics in pseudoexfoliation glaucoma, primary open-angle glaucoma and healthy controls using Corvis ST

PURPOSE: To compare the corneal biomechanical parameters between pseudoexfoliation glaucoma (PXG), primary open-angle glaucoma (POAG) and healthy controls using Corvis ST. METHODS: A prospective, cross-sectional study was conducted which included 132 treatment-naïve eyes which underwent Corvis ST. T...

Descripción completa

Detalles Bibliográficos
Autores principales: Pradhan, Zia Sultan, Deshmukh, Sujit, Dixit, Shivani, Sreenivasaiah, Shruthi, Shroff, Sujani, Devi, Sathi, Webers, Carroll A. B., Rao, Harsha Laxmana
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7588080/
https://www.ncbi.nlm.nih.gov/pubmed/33104764
http://dx.doi.org/10.1371/journal.pone.0241296
_version_ 1783600307792510976
author Pradhan, Zia Sultan
Deshmukh, Sujit
Dixit, Shivani
Sreenivasaiah, Shruthi
Shroff, Sujani
Devi, Sathi
Webers, Carroll A. B.
Rao, Harsha Laxmana
author_facet Pradhan, Zia Sultan
Deshmukh, Sujit
Dixit, Shivani
Sreenivasaiah, Shruthi
Shroff, Sujani
Devi, Sathi
Webers, Carroll A. B.
Rao, Harsha Laxmana
author_sort Pradhan, Zia Sultan
collection PubMed
description PURPOSE: To compare the corneal biomechanical parameters between pseudoexfoliation glaucoma (PXG), primary open-angle glaucoma (POAG) and healthy controls using Corvis ST. METHODS: A prospective, cross-sectional study was conducted which included 132 treatment-naïve eyes which underwent Corvis ST. The study cohort comprised of 44 eyes with PXG, 42 eyes with POAG and 46 healthy controls. Corneal biomechanical parameters, which included corneal velocities, length of corneal applanated surface, deformation amplitude (DA), peak distance and radius of curvature, were compared between the groups using analysis of variance models. RESULTS: The 3 groups were demographically similar. The mean IOP was 15.7 ±3 mmHg in the control group, 21.3 ±5 mmHg in the POAG group and 25.8 ±7 mmHg in the PXG group (p<0.0001). Corneal pachymetry was similar across the 3 groups. Mean DA was significantly lower (p<0.0001) in the PXG group (0.86 ±0.18 mm) compared to the POAG group (0.97 ±0.14mm) and the control group (1.10 ±0.15mm). Corneal velocities were also found to be statistically significantly different between the groups. However, after adjusting for IOP, there was no difference in any of the biomechanical parameters between the 3 groups. CONCLUSION: Corneal biomechanical parameters measured on Corvis ST are not different between eyes with PXG, POAG and healthy controls after adjusting for IOP.
format Online
Article
Text
id pubmed-7588080
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-75880802020-10-30 A comparison of the corneal biomechanics in pseudoexfoliation glaucoma, primary open-angle glaucoma and healthy controls using Corvis ST Pradhan, Zia Sultan Deshmukh, Sujit Dixit, Shivani Sreenivasaiah, Shruthi Shroff, Sujani Devi, Sathi Webers, Carroll A. B. Rao, Harsha Laxmana PLoS One Research Article PURPOSE: To compare the corneal biomechanical parameters between pseudoexfoliation glaucoma (PXG), primary open-angle glaucoma (POAG) and healthy controls using Corvis ST. METHODS: A prospective, cross-sectional study was conducted which included 132 treatment-naïve eyes which underwent Corvis ST. The study cohort comprised of 44 eyes with PXG, 42 eyes with POAG and 46 healthy controls. Corneal biomechanical parameters, which included corneal velocities, length of corneal applanated surface, deformation amplitude (DA), peak distance and radius of curvature, were compared between the groups using analysis of variance models. RESULTS: The 3 groups were demographically similar. The mean IOP was 15.7 ±3 mmHg in the control group, 21.3 ±5 mmHg in the POAG group and 25.8 ±7 mmHg in the PXG group (p<0.0001). Corneal pachymetry was similar across the 3 groups. Mean DA was significantly lower (p<0.0001) in the PXG group (0.86 ±0.18 mm) compared to the POAG group (0.97 ±0.14mm) and the control group (1.10 ±0.15mm). Corneal velocities were also found to be statistically significantly different between the groups. However, after adjusting for IOP, there was no difference in any of the biomechanical parameters between the 3 groups. CONCLUSION: Corneal biomechanical parameters measured on Corvis ST are not different between eyes with PXG, POAG and healthy controls after adjusting for IOP. Public Library of Science 2020-10-26 /pmc/articles/PMC7588080/ /pubmed/33104764 http://dx.doi.org/10.1371/journal.pone.0241296 Text en © 2020 Pradhan et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Pradhan, Zia Sultan
Deshmukh, Sujit
Dixit, Shivani
Sreenivasaiah, Shruthi
Shroff, Sujani
Devi, Sathi
Webers, Carroll A. B.
Rao, Harsha Laxmana
A comparison of the corneal biomechanics in pseudoexfoliation glaucoma, primary open-angle glaucoma and healthy controls using Corvis ST
title A comparison of the corneal biomechanics in pseudoexfoliation glaucoma, primary open-angle glaucoma and healthy controls using Corvis ST
title_full A comparison of the corneal biomechanics in pseudoexfoliation glaucoma, primary open-angle glaucoma and healthy controls using Corvis ST
title_fullStr A comparison of the corneal biomechanics in pseudoexfoliation glaucoma, primary open-angle glaucoma and healthy controls using Corvis ST
title_full_unstemmed A comparison of the corneal biomechanics in pseudoexfoliation glaucoma, primary open-angle glaucoma and healthy controls using Corvis ST
title_short A comparison of the corneal biomechanics in pseudoexfoliation glaucoma, primary open-angle glaucoma and healthy controls using Corvis ST
title_sort comparison of the corneal biomechanics in pseudoexfoliation glaucoma, primary open-angle glaucoma and healthy controls using corvis st
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7588080/
https://www.ncbi.nlm.nih.gov/pubmed/33104764
http://dx.doi.org/10.1371/journal.pone.0241296
work_keys_str_mv AT pradhanziasultan acomparisonofthecornealbiomechanicsinpseudoexfoliationglaucomaprimaryopenangleglaucomaandhealthycontrolsusingcorvisst
AT deshmukhsujit acomparisonofthecornealbiomechanicsinpseudoexfoliationglaucomaprimaryopenangleglaucomaandhealthycontrolsusingcorvisst
AT dixitshivani acomparisonofthecornealbiomechanicsinpseudoexfoliationglaucomaprimaryopenangleglaucomaandhealthycontrolsusingcorvisst
AT sreenivasaiahshruthi acomparisonofthecornealbiomechanicsinpseudoexfoliationglaucomaprimaryopenangleglaucomaandhealthycontrolsusingcorvisst
AT shroffsujani acomparisonofthecornealbiomechanicsinpseudoexfoliationglaucomaprimaryopenangleglaucomaandhealthycontrolsusingcorvisst
AT devisathi acomparisonofthecornealbiomechanicsinpseudoexfoliationglaucomaprimaryopenangleglaucomaandhealthycontrolsusingcorvisst
AT weberscarrollab acomparisonofthecornealbiomechanicsinpseudoexfoliationglaucomaprimaryopenangleglaucomaandhealthycontrolsusingcorvisst
AT raoharshalaxmana acomparisonofthecornealbiomechanicsinpseudoexfoliationglaucomaprimaryopenangleglaucomaandhealthycontrolsusingcorvisst
AT pradhanziasultan comparisonofthecornealbiomechanicsinpseudoexfoliationglaucomaprimaryopenangleglaucomaandhealthycontrolsusingcorvisst
AT deshmukhsujit comparisonofthecornealbiomechanicsinpseudoexfoliationglaucomaprimaryopenangleglaucomaandhealthycontrolsusingcorvisst
AT dixitshivani comparisonofthecornealbiomechanicsinpseudoexfoliationglaucomaprimaryopenangleglaucomaandhealthycontrolsusingcorvisst
AT sreenivasaiahshruthi comparisonofthecornealbiomechanicsinpseudoexfoliationglaucomaprimaryopenangleglaucomaandhealthycontrolsusingcorvisst
AT shroffsujani comparisonofthecornealbiomechanicsinpseudoexfoliationglaucomaprimaryopenangleglaucomaandhealthycontrolsusingcorvisst
AT devisathi comparisonofthecornealbiomechanicsinpseudoexfoliationglaucomaprimaryopenangleglaucomaandhealthycontrolsusingcorvisst
AT weberscarrollab comparisonofthecornealbiomechanicsinpseudoexfoliationglaucomaprimaryopenangleglaucomaandhealthycontrolsusingcorvisst
AT raoharshalaxmana comparisonofthecornealbiomechanicsinpseudoexfoliationglaucomaprimaryopenangleglaucomaandhealthycontrolsusingcorvisst