Cargando…

Calibration of In-Plane Center Alignment Errors in the Installation of a Circular Slide with Machine-Vision Sensor and a Reflective Marker

This paper describes a method for calibrating in-plane center alignment error (IPCA) that occurs when installing the circular motion slide (CMS). In this study, by combini ng the moving carriage of the CMS and the planar PKM (parallel kinematic mechanism) with the machine tool, the small workspace o...

Descripción completa

Detalles Bibliográficos
Autores principales: Jeong, Hyungjin, Yu, Jiwon, Lee, Donghun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7589117/
https://www.ncbi.nlm.nih.gov/pubmed/33092082
http://dx.doi.org/10.3390/s20205916
_version_ 1783600504790581248
author Jeong, Hyungjin
Yu, Jiwon
Lee, Donghun
author_facet Jeong, Hyungjin
Yu, Jiwon
Lee, Donghun
author_sort Jeong, Hyungjin
collection PubMed
description This paper describes a method for calibrating in-plane center alignment error (IPCA) that occurs when installing the circular motion slide (CMS). In this study, by combini ng the moving carriage of the CMS and the planar PKM (parallel kinematic mechanism) with the machine tool, the small workspace of the PKM is expanded, and the workpiece is placed on the table with the CMS installed is processed through the machine tool. However, to rigidly mount the CMS on the table, the preload between the guide and the support bearings must be adjusted with the eccentric bearing, and in this process, the IPCA occurs. After installing a reflective marker on the PKM, the PKM is slowly rotated along with the ring guide in the way of stop-and-go without the PKM’s own motion. Then, using a machine vision camera installed at the top of the CMS, the IPCA, which is the difference between the actual center position and the nominal center position of the CMS with respect to the camera, can be successfully calibrated through the circular fitting process. Consequently, it was confirmed that the IPCA of 0.37 mm can be successfully identified with the proposed method.
format Online
Article
Text
id pubmed-7589117
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-75891172020-10-29 Calibration of In-Plane Center Alignment Errors in the Installation of a Circular Slide with Machine-Vision Sensor and a Reflective Marker Jeong, Hyungjin Yu, Jiwon Lee, Donghun Sensors (Basel) Letter This paper describes a method for calibrating in-plane center alignment error (IPCA) that occurs when installing the circular motion slide (CMS). In this study, by combini ng the moving carriage of the CMS and the planar PKM (parallel kinematic mechanism) with the machine tool, the small workspace of the PKM is expanded, and the workpiece is placed on the table with the CMS installed is processed through the machine tool. However, to rigidly mount the CMS on the table, the preload between the guide and the support bearings must be adjusted with the eccentric bearing, and in this process, the IPCA occurs. After installing a reflective marker on the PKM, the PKM is slowly rotated along with the ring guide in the way of stop-and-go without the PKM’s own motion. Then, using a machine vision camera installed at the top of the CMS, the IPCA, which is the difference between the actual center position and the nominal center position of the CMS with respect to the camera, can be successfully calibrated through the circular fitting process. Consequently, it was confirmed that the IPCA of 0.37 mm can be successfully identified with the proposed method. MDPI 2020-10-20 /pmc/articles/PMC7589117/ /pubmed/33092082 http://dx.doi.org/10.3390/s20205916 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Letter
Jeong, Hyungjin
Yu, Jiwon
Lee, Donghun
Calibration of In-Plane Center Alignment Errors in the Installation of a Circular Slide with Machine-Vision Sensor and a Reflective Marker
title Calibration of In-Plane Center Alignment Errors in the Installation of a Circular Slide with Machine-Vision Sensor and a Reflective Marker
title_full Calibration of In-Plane Center Alignment Errors in the Installation of a Circular Slide with Machine-Vision Sensor and a Reflective Marker
title_fullStr Calibration of In-Plane Center Alignment Errors in the Installation of a Circular Slide with Machine-Vision Sensor and a Reflective Marker
title_full_unstemmed Calibration of In-Plane Center Alignment Errors in the Installation of a Circular Slide with Machine-Vision Sensor and a Reflective Marker
title_short Calibration of In-Plane Center Alignment Errors in the Installation of a Circular Slide with Machine-Vision Sensor and a Reflective Marker
title_sort calibration of in-plane center alignment errors in the installation of a circular slide with machine-vision sensor and a reflective marker
topic Letter
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7589117/
https://www.ncbi.nlm.nih.gov/pubmed/33092082
http://dx.doi.org/10.3390/s20205916
work_keys_str_mv AT jeonghyungjin calibrationofinplanecenteralignmenterrorsintheinstallationofacircularslidewithmachinevisionsensorandareflectivemarker
AT yujiwon calibrationofinplanecenteralignmenterrorsintheinstallationofacircularslidewithmachinevisionsensorandareflectivemarker
AT leedonghun calibrationofinplanecenteralignmenterrorsintheinstallationofacircularslidewithmachinevisionsensorandareflectivemarker