Cargando…

The predictive value of the Pleth Variability Index on fluid responsiveness in spontaneously breathing anaesthetized children—A prospective observational study

BACKGROUND: In children, the preoperative hydration status is an important part of the overall clinical assessment. The assumed preoperative fluid deficit is often routinely replaced during induction without knowing the child's actual fluid status. AIM: We investigated the predictive value of t...

Descripción completa

Detalles Bibliográficos
Autores principales: Weber, Frank, Rashmi, Bharat K., Karaoz‐Bulut, Gülhan, Dogger, Jaap, de Heer, Iris J., Prasser, Christopher
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7589325/
https://www.ncbi.nlm.nih.gov/pubmed/32767812
http://dx.doi.org/10.1111/pan.13991
_version_ 1783600552857305088
author Weber, Frank
Rashmi, Bharat K.
Karaoz‐Bulut, Gülhan
Dogger, Jaap
de Heer, Iris J.
Prasser, Christopher
author_facet Weber, Frank
Rashmi, Bharat K.
Karaoz‐Bulut, Gülhan
Dogger, Jaap
de Heer, Iris J.
Prasser, Christopher
author_sort Weber, Frank
collection PubMed
description BACKGROUND: In children, the preoperative hydration status is an important part of the overall clinical assessment. The assumed preoperative fluid deficit is often routinely replaced during induction without knowing the child's actual fluid status. AIM: We investigated the predictive value of the Pleth Variability Index as a measure of fluid responsiveness in spontaneously breathing anesthetized children. METHODS: Pleth Variability Index, stroke volume and Cardiac Index, measured by electrovelocimetry, mean blood pressure, and heart rate were recorded during anesthesia induction in 50 pediatric patients <6 years. Baseline values were compared to values recorded after administration of 10 mL/kg of Ringer's lactate and during two passive leg raising tests (before and after fluid administration). Fluid responsiveness was defined as an increase of ≥10% in stroke volume. RESULTS: Only in fluid responsive patients, Pleth Variability Index values were higher before fluid administration than thereafter (21.4 ± 5.9% vs 15.0 ± 9.4%, 95% CI of difference 1.1 to 11.8%, P = .02). Pleth Variability Index values at baseline were higher in fluid responders (21.4 ± 5.9%) than in fluid nonresponders (15.3 ± 7.7%), 95% CI of difference 1.6 to 10.6%, P = .009. The area under the receiver operating curve indicating fluid responsiveness was 0.781 (95% CI 0.623 to 0.896, P = .0002), with the highest sensitivity (82%) and specificity (70%) at a Pleth Variability Index of >15% (Positive predictive value 2.71 (95% CI: 1.4 to 5.2)). Only in fluid responders, the Pleth Variability Index decreased during passive leg raising, while stroke volume increased. CONCLUSIONS: The Pleth Variability Index may be of additional value to predict fluid responsiveness in spontaneously breathing anesthetized children. A significant overlap in baseline Pleth Variability Index values between fluid responsive and nonfluid responsive patients does not allow a reliable recommendation as to a cut off value.
format Online
Article
Text
id pubmed-7589325
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-75893252020-10-30 The predictive value of the Pleth Variability Index on fluid responsiveness in spontaneously breathing anaesthetized children—A prospective observational study Weber, Frank Rashmi, Bharat K. Karaoz‐Bulut, Gülhan Dogger, Jaap de Heer, Iris J. Prasser, Christopher Paediatr Anaesth Research Reports BACKGROUND: In children, the preoperative hydration status is an important part of the overall clinical assessment. The assumed preoperative fluid deficit is often routinely replaced during induction without knowing the child's actual fluid status. AIM: We investigated the predictive value of the Pleth Variability Index as a measure of fluid responsiveness in spontaneously breathing anesthetized children. METHODS: Pleth Variability Index, stroke volume and Cardiac Index, measured by electrovelocimetry, mean blood pressure, and heart rate were recorded during anesthesia induction in 50 pediatric patients <6 years. Baseline values were compared to values recorded after administration of 10 mL/kg of Ringer's lactate and during two passive leg raising tests (before and after fluid administration). Fluid responsiveness was defined as an increase of ≥10% in stroke volume. RESULTS: Only in fluid responsive patients, Pleth Variability Index values were higher before fluid administration than thereafter (21.4 ± 5.9% vs 15.0 ± 9.4%, 95% CI of difference 1.1 to 11.8%, P = .02). Pleth Variability Index values at baseline were higher in fluid responders (21.4 ± 5.9%) than in fluid nonresponders (15.3 ± 7.7%), 95% CI of difference 1.6 to 10.6%, P = .009. The area under the receiver operating curve indicating fluid responsiveness was 0.781 (95% CI 0.623 to 0.896, P = .0002), with the highest sensitivity (82%) and specificity (70%) at a Pleth Variability Index of >15% (Positive predictive value 2.71 (95% CI: 1.4 to 5.2)). Only in fluid responders, the Pleth Variability Index decreased during passive leg raising, while stroke volume increased. CONCLUSIONS: The Pleth Variability Index may be of additional value to predict fluid responsiveness in spontaneously breathing anesthetized children. A significant overlap in baseline Pleth Variability Index values between fluid responsive and nonfluid responsive patients does not allow a reliable recommendation as to a cut off value. John Wiley and Sons Inc. 2020-08-29 2020-10 /pmc/articles/PMC7589325/ /pubmed/32767812 http://dx.doi.org/10.1111/pan.13991 Text en © 2020 The Authors. Pediatric Anesthesia published by John Wiley & Sons Ltd. This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made.
spellingShingle Research Reports
Weber, Frank
Rashmi, Bharat K.
Karaoz‐Bulut, Gülhan
Dogger, Jaap
de Heer, Iris J.
Prasser, Christopher
The predictive value of the Pleth Variability Index on fluid responsiveness in spontaneously breathing anaesthetized children—A prospective observational study
title The predictive value of the Pleth Variability Index on fluid responsiveness in spontaneously breathing anaesthetized children—A prospective observational study
title_full The predictive value of the Pleth Variability Index on fluid responsiveness in spontaneously breathing anaesthetized children—A prospective observational study
title_fullStr The predictive value of the Pleth Variability Index on fluid responsiveness in spontaneously breathing anaesthetized children—A prospective observational study
title_full_unstemmed The predictive value of the Pleth Variability Index on fluid responsiveness in spontaneously breathing anaesthetized children—A prospective observational study
title_short The predictive value of the Pleth Variability Index on fluid responsiveness in spontaneously breathing anaesthetized children—A prospective observational study
title_sort predictive value of the pleth variability index on fluid responsiveness in spontaneously breathing anaesthetized children—a prospective observational study
topic Research Reports
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7589325/
https://www.ncbi.nlm.nih.gov/pubmed/32767812
http://dx.doi.org/10.1111/pan.13991
work_keys_str_mv AT weberfrank thepredictivevalueoftheplethvariabilityindexonfluidresponsivenessinspontaneouslybreathinganaesthetizedchildrenaprospectiveobservationalstudy
AT rashmibharatk thepredictivevalueoftheplethvariabilityindexonfluidresponsivenessinspontaneouslybreathinganaesthetizedchildrenaprospectiveobservationalstudy
AT karaozbulutgulhan thepredictivevalueoftheplethvariabilityindexonfluidresponsivenessinspontaneouslybreathinganaesthetizedchildrenaprospectiveobservationalstudy
AT doggerjaap thepredictivevalueoftheplethvariabilityindexonfluidresponsivenessinspontaneouslybreathinganaesthetizedchildrenaprospectiveobservationalstudy
AT deheeririsj thepredictivevalueoftheplethvariabilityindexonfluidresponsivenessinspontaneouslybreathinganaesthetizedchildrenaprospectiveobservationalstudy
AT prasserchristopher thepredictivevalueoftheplethvariabilityindexonfluidresponsivenessinspontaneouslybreathinganaesthetizedchildrenaprospectiveobservationalstudy
AT weberfrank predictivevalueoftheplethvariabilityindexonfluidresponsivenessinspontaneouslybreathinganaesthetizedchildrenaprospectiveobservationalstudy
AT rashmibharatk predictivevalueoftheplethvariabilityindexonfluidresponsivenessinspontaneouslybreathinganaesthetizedchildrenaprospectiveobservationalstudy
AT karaozbulutgulhan predictivevalueoftheplethvariabilityindexonfluidresponsivenessinspontaneouslybreathinganaesthetizedchildrenaprospectiveobservationalstudy
AT doggerjaap predictivevalueoftheplethvariabilityindexonfluidresponsivenessinspontaneouslybreathinganaesthetizedchildrenaprospectiveobservationalstudy
AT deheeririsj predictivevalueoftheplethvariabilityindexonfluidresponsivenessinspontaneouslybreathinganaesthetizedchildrenaprospectiveobservationalstudy
AT prasserchristopher predictivevalueoftheplethvariabilityindexonfluidresponsivenessinspontaneouslybreathinganaesthetizedchildrenaprospectiveobservationalstudy