Cargando…
Frequency and Duration of SARS-CoV-2 Shedding in Oral Fluid Samples Assessed by a Modified Commercial Rapid Molecular Assay
Background: RT-PCR on nasopharyngeal (NPS)/oropharyngeal swabs is the gold standard for diagnosis of SARS-CoV-2 infection and viral load monitoring. Oral fluid (OF) is an alternate clinical sample, easy and safer to collect and could be useful for COVID-19 diagnosis, monitoring viral load and sheddi...
Autores principales: | , , , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7589602/ https://www.ncbi.nlm.nih.gov/pubmed/33092065 http://dx.doi.org/10.3390/v12101184 |
_version_ | 1783600616363261952 |
---|---|
author | Bordi, Licia Sberna, Giuseppe Lalle, Eleonora Piselli, Pierluca Colavita, Francesca Nicastri, Emanuele Antinori, Andrea Boumis, Evangelo Petrosillo, Nicola Marchioni, Luisa Minnucci, Giulia D’Agostini, Elena Castilletti, Concetta Locatelli, Franco Zumla, Alimuddin Ippolito, Giuseppe Capobianchi, Maria Rosaria |
author_facet | Bordi, Licia Sberna, Giuseppe Lalle, Eleonora Piselli, Pierluca Colavita, Francesca Nicastri, Emanuele Antinori, Andrea Boumis, Evangelo Petrosillo, Nicola Marchioni, Luisa Minnucci, Giulia D’Agostini, Elena Castilletti, Concetta Locatelli, Franco Zumla, Alimuddin Ippolito, Giuseppe Capobianchi, Maria Rosaria |
author_sort | Bordi, Licia |
collection | PubMed |
description | Background: RT-PCR on nasopharyngeal (NPS)/oropharyngeal swabs is the gold standard for diagnosis of SARS-CoV-2 infection and viral load monitoring. Oral fluid (OF) is an alternate clinical sample, easy and safer to collect and could be useful for COVID-19 diagnosis, monitoring viral load and shedding. Methods: Optimal assay conditions and analytical sensitivity were established for the commercial Simplexa™ COVID-19 Direct assay adapted to OF matrix. The assay was used to test 337 OF and NPS specimens collected in parallel from 164 hospitalized patients; 50 bronchoalveolar lavage (BAL) specimens from a subgroup of severe COVID-19 cases were also analysed. Results: Using Simplexa™ COVID-19 Direct on OF matrix, 100% analytical detection down to 1 TCID50/mL (corresponding to 4 × 10(3) copies (cp)/mL) was observed. No crossreaction with other viruses transmitted through the respiratory toute was observed. Parallel testing of 337 OF and NPS samples showed highly concordant results (κ = 0.831; 95 % CI = 0.771–0.891), and high correlation of Ct values (r = 0.921; p < 0.0001). High concordance and elevated correlation was observed also between OF and BAL. Prolonged viral RNA shedding was observed up to 100 days from symptoms onset (DSO), with 32% and 29% positivity observed in OF and NPS samples, respectively, collected between 60 and 100 DSO. Conclusions: Simplexa™ COVID-19 Direct assays on OF have high sensitivity and specificity to detect SARS-CoV-2 RNA and provide an alternative to NPS for diagnosis and monitoring SARS-CoV-2 shedding. |
format | Online Article Text |
id | pubmed-7589602 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-75896022020-10-29 Frequency and Duration of SARS-CoV-2 Shedding in Oral Fluid Samples Assessed by a Modified Commercial Rapid Molecular Assay Bordi, Licia Sberna, Giuseppe Lalle, Eleonora Piselli, Pierluca Colavita, Francesca Nicastri, Emanuele Antinori, Andrea Boumis, Evangelo Petrosillo, Nicola Marchioni, Luisa Minnucci, Giulia D’Agostini, Elena Castilletti, Concetta Locatelli, Franco Zumla, Alimuddin Ippolito, Giuseppe Capobianchi, Maria Rosaria Viruses Article Background: RT-PCR on nasopharyngeal (NPS)/oropharyngeal swabs is the gold standard for diagnosis of SARS-CoV-2 infection and viral load monitoring. Oral fluid (OF) is an alternate clinical sample, easy and safer to collect and could be useful for COVID-19 diagnosis, monitoring viral load and shedding. Methods: Optimal assay conditions and analytical sensitivity were established for the commercial Simplexa™ COVID-19 Direct assay adapted to OF matrix. The assay was used to test 337 OF and NPS specimens collected in parallel from 164 hospitalized patients; 50 bronchoalveolar lavage (BAL) specimens from a subgroup of severe COVID-19 cases were also analysed. Results: Using Simplexa™ COVID-19 Direct on OF matrix, 100% analytical detection down to 1 TCID50/mL (corresponding to 4 × 10(3) copies (cp)/mL) was observed. No crossreaction with other viruses transmitted through the respiratory toute was observed. Parallel testing of 337 OF and NPS samples showed highly concordant results (κ = 0.831; 95 % CI = 0.771–0.891), and high correlation of Ct values (r = 0.921; p < 0.0001). High concordance and elevated correlation was observed also between OF and BAL. Prolonged viral RNA shedding was observed up to 100 days from symptoms onset (DSO), with 32% and 29% positivity observed in OF and NPS samples, respectively, collected between 60 and 100 DSO. Conclusions: Simplexa™ COVID-19 Direct assays on OF have high sensitivity and specificity to detect SARS-CoV-2 RNA and provide an alternative to NPS for diagnosis and monitoring SARS-CoV-2 shedding. MDPI 2020-10-20 /pmc/articles/PMC7589602/ /pubmed/33092065 http://dx.doi.org/10.3390/v12101184 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Bordi, Licia Sberna, Giuseppe Lalle, Eleonora Piselli, Pierluca Colavita, Francesca Nicastri, Emanuele Antinori, Andrea Boumis, Evangelo Petrosillo, Nicola Marchioni, Luisa Minnucci, Giulia D’Agostini, Elena Castilletti, Concetta Locatelli, Franco Zumla, Alimuddin Ippolito, Giuseppe Capobianchi, Maria Rosaria Frequency and Duration of SARS-CoV-2 Shedding in Oral Fluid Samples Assessed by a Modified Commercial Rapid Molecular Assay |
title | Frequency and Duration of SARS-CoV-2 Shedding in Oral Fluid Samples Assessed by a Modified Commercial Rapid Molecular Assay |
title_full | Frequency and Duration of SARS-CoV-2 Shedding in Oral Fluid Samples Assessed by a Modified Commercial Rapid Molecular Assay |
title_fullStr | Frequency and Duration of SARS-CoV-2 Shedding in Oral Fluid Samples Assessed by a Modified Commercial Rapid Molecular Assay |
title_full_unstemmed | Frequency and Duration of SARS-CoV-2 Shedding in Oral Fluid Samples Assessed by a Modified Commercial Rapid Molecular Assay |
title_short | Frequency and Duration of SARS-CoV-2 Shedding in Oral Fluid Samples Assessed by a Modified Commercial Rapid Molecular Assay |
title_sort | frequency and duration of sars-cov-2 shedding in oral fluid samples assessed by a modified commercial rapid molecular assay |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7589602/ https://www.ncbi.nlm.nih.gov/pubmed/33092065 http://dx.doi.org/10.3390/v12101184 |
work_keys_str_mv | AT bordilicia frequencyanddurationofsarscov2sheddinginoralfluidsamplesassessedbyamodifiedcommercialrapidmolecularassay AT sbernagiuseppe frequencyanddurationofsarscov2sheddinginoralfluidsamplesassessedbyamodifiedcommercialrapidmolecularassay AT lalleeleonora frequencyanddurationofsarscov2sheddinginoralfluidsamplesassessedbyamodifiedcommercialrapidmolecularassay AT pisellipierluca frequencyanddurationofsarscov2sheddinginoralfluidsamplesassessedbyamodifiedcommercialrapidmolecularassay AT colavitafrancesca frequencyanddurationofsarscov2sheddinginoralfluidsamplesassessedbyamodifiedcommercialrapidmolecularassay AT nicastriemanuele frequencyanddurationofsarscov2sheddinginoralfluidsamplesassessedbyamodifiedcommercialrapidmolecularassay AT antinoriandrea frequencyanddurationofsarscov2sheddinginoralfluidsamplesassessedbyamodifiedcommercialrapidmolecularassay AT boumisevangelo frequencyanddurationofsarscov2sheddinginoralfluidsamplesassessedbyamodifiedcommercialrapidmolecularassay AT petrosillonicola frequencyanddurationofsarscov2sheddinginoralfluidsamplesassessedbyamodifiedcommercialrapidmolecularassay AT marchioniluisa frequencyanddurationofsarscov2sheddinginoralfluidsamplesassessedbyamodifiedcommercialrapidmolecularassay AT minnuccigiulia frequencyanddurationofsarscov2sheddinginoralfluidsamplesassessedbyamodifiedcommercialrapidmolecularassay AT dagostinielena frequencyanddurationofsarscov2sheddinginoralfluidsamplesassessedbyamodifiedcommercialrapidmolecularassay AT castilletticoncetta frequencyanddurationofsarscov2sheddinginoralfluidsamplesassessedbyamodifiedcommercialrapidmolecularassay AT locatellifranco frequencyanddurationofsarscov2sheddinginoralfluidsamplesassessedbyamodifiedcommercialrapidmolecularassay AT zumlaalimuddin frequencyanddurationofsarscov2sheddinginoralfluidsamplesassessedbyamodifiedcommercialrapidmolecularassay AT ippolitogiuseppe frequencyanddurationofsarscov2sheddinginoralfluidsamplesassessedbyamodifiedcommercialrapidmolecularassay AT capobianchimariarosaria frequencyanddurationofsarscov2sheddinginoralfluidsamplesassessedbyamodifiedcommercialrapidmolecularassay AT frequencyanddurationofsarscov2sheddinginoralfluidsamplesassessedbyamodifiedcommercialrapidmolecularassay |