Cargando…
Evaluation of the Milling Accuracy of Zirconia-Reinforced Lithium Silicate Crowns Fabricated Using the Dental Medical Device System: A Three-Dimensional Analysis
This study aimed to analyze the milling accuracy of lithium disilicate and zirconia-reinforced silicate crown fabricated using chairside computer-aided design/manufacturing (CAD/CAM) system. Mandibular left first premolar was selected for abutment. A master model was obtained for digital impression...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7589780/ https://www.ncbi.nlm.nih.gov/pubmed/33096621 http://dx.doi.org/10.3390/ma13204680 |
_version_ | 1783600657897357312 |
---|---|
author | Kang, Seen-Young Yu, Ji-Min Lee, Jun-Seok Park, Ki-Sook Lee, Seung-Youl |
author_facet | Kang, Seen-Young Yu, Ji-Min Lee, Jun-Seok Park, Ki-Sook Lee, Seung-Youl |
author_sort | Kang, Seen-Young |
collection | PubMed |
description | This study aimed to analyze the milling accuracy of lithium disilicate and zirconia-reinforced silicate crown fabricated using chairside computer-aided design/manufacturing (CAD/CAM) system. Mandibular left first premolar was selected for abutment. A master model was obtained for digital impression using an intraoral scanner, and crowns were designed using a CAD software design program. Amber Mill (AM), IPS e max CAD (IPS), and CELTRA DUO (CEL) were used in the CAD/CAM system, and a total 45 crowns (15 crowns each for AM, IPS, and CEL) was fabricated. Milling accuracy was analyzed with respect to trueness, measured by superimposing CAD design data and scan data through a three-dimensional program to compare the outer and inner surfaces and internal and external parts, thereby acquiring both quantitative and qualitative data. Data were analyzed using the non-parametric test and Kruskal–Wallis H test. In addition, the Mann–Whitney U test was used by applying the level of significance (0.05/3 = 0.016) adjusted by post-analysis Bonferroni correction. All the measured parts of the lithium disilicate and zirconia-reinforced silicate crowns showed statistically significant differences (p < 0.05). The lithium disilicate (AM and IPS) materials showed superior milling accuracy than the zirconia-reinforced lithium silicate (CEL) materials. |
format | Online Article Text |
id | pubmed-7589780 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-75897802020-10-29 Evaluation of the Milling Accuracy of Zirconia-Reinforced Lithium Silicate Crowns Fabricated Using the Dental Medical Device System: A Three-Dimensional Analysis Kang, Seen-Young Yu, Ji-Min Lee, Jun-Seok Park, Ki-Sook Lee, Seung-Youl Materials (Basel) Article This study aimed to analyze the milling accuracy of lithium disilicate and zirconia-reinforced silicate crown fabricated using chairside computer-aided design/manufacturing (CAD/CAM) system. Mandibular left first premolar was selected for abutment. A master model was obtained for digital impression using an intraoral scanner, and crowns were designed using a CAD software design program. Amber Mill (AM), IPS e max CAD (IPS), and CELTRA DUO (CEL) were used in the CAD/CAM system, and a total 45 crowns (15 crowns each for AM, IPS, and CEL) was fabricated. Milling accuracy was analyzed with respect to trueness, measured by superimposing CAD design data and scan data through a three-dimensional program to compare the outer and inner surfaces and internal and external parts, thereby acquiring both quantitative and qualitative data. Data were analyzed using the non-parametric test and Kruskal–Wallis H test. In addition, the Mann–Whitney U test was used by applying the level of significance (0.05/3 = 0.016) adjusted by post-analysis Bonferroni correction. All the measured parts of the lithium disilicate and zirconia-reinforced silicate crowns showed statistically significant differences (p < 0.05). The lithium disilicate (AM and IPS) materials showed superior milling accuracy than the zirconia-reinforced lithium silicate (CEL) materials. MDPI 2020-10-21 /pmc/articles/PMC7589780/ /pubmed/33096621 http://dx.doi.org/10.3390/ma13204680 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Kang, Seen-Young Yu, Ji-Min Lee, Jun-Seok Park, Ki-Sook Lee, Seung-Youl Evaluation of the Milling Accuracy of Zirconia-Reinforced Lithium Silicate Crowns Fabricated Using the Dental Medical Device System: A Three-Dimensional Analysis |
title | Evaluation of the Milling Accuracy of Zirconia-Reinforced Lithium Silicate Crowns Fabricated Using the Dental Medical Device System: A Three-Dimensional Analysis |
title_full | Evaluation of the Milling Accuracy of Zirconia-Reinforced Lithium Silicate Crowns Fabricated Using the Dental Medical Device System: A Three-Dimensional Analysis |
title_fullStr | Evaluation of the Milling Accuracy of Zirconia-Reinforced Lithium Silicate Crowns Fabricated Using the Dental Medical Device System: A Three-Dimensional Analysis |
title_full_unstemmed | Evaluation of the Milling Accuracy of Zirconia-Reinforced Lithium Silicate Crowns Fabricated Using the Dental Medical Device System: A Three-Dimensional Analysis |
title_short | Evaluation of the Milling Accuracy of Zirconia-Reinforced Lithium Silicate Crowns Fabricated Using the Dental Medical Device System: A Three-Dimensional Analysis |
title_sort | evaluation of the milling accuracy of zirconia-reinforced lithium silicate crowns fabricated using the dental medical device system: a three-dimensional analysis |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7589780/ https://www.ncbi.nlm.nih.gov/pubmed/33096621 http://dx.doi.org/10.3390/ma13204680 |
work_keys_str_mv | AT kangseenyoung evaluationofthemillingaccuracyofzirconiareinforcedlithiumsilicatecrownsfabricatedusingthedentalmedicaldevicesystemathreedimensionalanalysis AT yujimin evaluationofthemillingaccuracyofzirconiareinforcedlithiumsilicatecrownsfabricatedusingthedentalmedicaldevicesystemathreedimensionalanalysis AT leejunseok evaluationofthemillingaccuracyofzirconiareinforcedlithiumsilicatecrownsfabricatedusingthedentalmedicaldevicesystemathreedimensionalanalysis AT parkkisook evaluationofthemillingaccuracyofzirconiareinforcedlithiumsilicatecrownsfabricatedusingthedentalmedicaldevicesystemathreedimensionalanalysis AT leeseungyoul evaluationofthemillingaccuracyofzirconiareinforcedlithiumsilicatecrownsfabricatedusingthedentalmedicaldevicesystemathreedimensionalanalysis |